NiO0.99Cu0.01 films have been deposited using thermal evaporation
technique on glass substrates under vacuum 10-5mbar. The thickness
of the films was 220nm. The as -deposited films were annealed to
different annealing temperatures (373, 423, and 473) K under
vacuum 10-3mbar for 1 h. The structural properties of the films were
examined using X-ray diffraction (XRD). The results show that no
clear diffraction peaks in the range 2θ= (20-50)o for the as deposited
films. On the other hand, by annealing the films to 423K in vacuum
for 1 h, a weak reflection peak attributable to cubic NiO was
detected. On heating the films at 473K for 1 h, this peak was
observed to be stronger. The most intense peak is at 2θ = 37.12o with
the preferential orientation of the films being (111) plane. The optical
properties of the films have been studied. The effect of annealing
temperature on the optical parameters of NiO0.99Cu0.01 such as
transmittance, reflectance, absorption coefficient, refractive index,
extinction coefficient, and real and imaginary parts of dielectric
constant has been reported.
Background: Diabetes mellitus a major factor that has adverse effects on the vascular system and the heart. It causes an increase in cardiac muscle thickness, resulting in decreased compliance and increased peripheral arterial stiffness. This study aims to assess the left ventricular mass (LVM) and left ventricular hemodynamic changes in diabetic patients measured by Doppler echocardiography. Patients and Methods: The study included 50 diabetic patients ranging in age between 25 and 80 years, (mean age: 54.1 ± 15.10, 19 males, 31 females) and 50 healthy subjects, aged 25 to 80 years (mean age: 48.52 ± 14.45, 11 males, 39 females). Doppler echocardiography was used to assess left ventricular function. The measurements included
... Show MoreBackground: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample in
... Show MoreIn this study, the stable isotop 18O and 2H has been used to investigate the interaction of surface water (SW), and groundwater (GW) in Al-Taji district/ Northern Baghdad for two seasons (March and August 2022). 16 Samples were collected from water resources in the Al-Taji district (Tigris channel, Tigris River, and groundwater), in each season water samples from 8 Tigris channel, 5 drilled wells, and 3 Tigris River were taken for the analysis of the isotopes 18O and 2H. The average analysis results of 18O and 2H in the Tigris channel, Tigris River, and groundwater were found to be -3.435‰ and -18.6094‰, -2.07167‰ and -17.81‰, -4.125‰ and -34.707‰ respectively. The results, generally, show a comparable range of isotope c
... Show MoreThe dual nature of asphalt binder necessitates improvements to mitigate rutting and fatigue since it performs as an elastic material under the regime of rapid loading or cold temperatures and as a viscous fluid at elevated temperatures. The present investigation assesses the effectiveness of Nano Alumina (NA), Nano Silica (NS), and Nano Titanium Dioxide (NT) at weight percentages of 0, 2, 4, 6, and 8% in asphalt cement to enhance both asphalt binder and mixture performance. Binder evaluations include tests for consistency, thermal susceptibility, aging, and workability, while mixture assessments focus on Marshall properties, moisture susceptibility, resilient modulus, permanent deformation, and fatigue characteristics. NS notably im
... Show MoreWe report herein an innovative approach to prostate tumor therapy using tumor specific radioactive gold nanoparticles (198Au) functionalized with Mangiferin (MGF). Production and full characterization of MGF-198AuNPs are described. In vivo therapeutic efficacy of MGF-198AuNPs, through intratumoral delivery, in SCID mice bearing prostate tumor xenografts are described. Singular doses of the nano-radiopharmaceutical (MGF-198AuNPs) resulted in over 85% reduction of tumor volume as compared to untreated control groups. The excellent anti-tumor efficacy of MGF-198AuNPs are attributed to the retention of over 90% of the injected dose within tumors for long periods of time. The retention of MGF-198AuNPs is also rationalized in terms of the higher
... Show MoreThe dual nature of asphalt binder necessitates improvements to mitigate rutting and fatigue since it performs as an elastic material under the regime of rapid loading or cold temperatures and as a viscous fluid at elevated temperatures. The present investigation assesses the effectiveness of Nano Alumina (NA), Nano Silica (NS), and Nano Titanium Dioxide (NT) at weight percentages of 0, 2, 4, 6, and 8% in asphalt cement to enhance both asphalt binder and mixture performance. Binder evaluations include tests for consistency, thermal susceptibility, aging, and workability, while mixture assessments focus on Marshall properties, moisture susceptibility, resilient modulus, permanent deformation, and fatigue characteristics. NS notably im
... Show MoreBackground: The clinical examination is one of the best suitable methods for diagnosis of low backache. Backache is one disease that the signs, clinical examination finding, and the results on imaging modalities not always related. The straight leg raising (SLR) and slump tests, can be used for diagnosis of lumber disc herniation. Objectives: To compare the result of the slump test and SLR test in the diagnosis of lumber disc herniation. Subjects and Methods: A prospective comparative study conducts on 280 patients in Al-Kindy teaching and private clinics complaints of backache, aging between 18-70 years old with acute or recurrent backache, sciatica pain, or low back and sciatica pain for last 12 weeks, while patients
... Show MoreObjective(s): The present study aims at assessing the prevalence of smoking among health workers in Baghdad Teaching Hospital and to find out the effectiveness of instructional booklet concerning risk of smoking on health workers′ knowledge in hospital.
Methodology: A pre-experimental design study was conducted from 1st of October 2019 to 17th of March 2020. A non-probability sample consists of (500) participant (343 non-smokers and 157 smokers) from (1500) health workers in Baghdad Teaching Hospital, they included the physicians, nurses, pharmacists, physiotherapists, Laboratory Technicians, Medical Assistants. A questionnaire is constructed to evaluate the effectiveness of instructional booklet on health workers’ knowledge