Determination the concentration of radon in human urine using LR-115 detector
...Show More Authors

In the present study twenty samples of human urine were taken
from healthy male and female with different of: ages, occupation and
place of residence. These samples were collected from the hospital to
measure the concentration of radon gas in human urine by using one
of solid state nuclear track detectors LR-115.
The results obtained of the concentrations of radon in healthy human
urine are varying from 2.12×10-3 Bq.l-1 to 4.42×10-3 Bq.l-1 and
these values are less than the allowed limits 12.3×10-3 Bq.l-1.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Effect of laser energy and pulses on size and concentration of gold nanoparticles in DDDW by LALP method
...Show More Authors

The size and the concentration of the gold nanoparticles (GNPs)
synthesized in double distilled deionized water (DDDW) have been
found to be affected by the laser energy and the number of pulses.
The absorption spectra of the nanoparticles DDDW, and the
surface plasmon resonance (SPR) peaks were measured, and found to
be located between (509 and 524)nm using the UV- Vis
spectrophotometer. SPR calculations, images of transmission
electron microscope, and dynamic light scattering (DLS) method
were used to determine the size of GNPs, which found to be ranged
between (3.5 and 27) nm. The concentrations of GNPs in colloidal
solutions found to be ranged between (37 and 142) ppm, and
measured by atomic absorptio

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Effect of CuI concentration on structural and optical properties of PVA: CuI nanocomposites
...Show More Authors

The nanocomposite on the base of synthesis Copper iodide
nanoparticles and polyvinyl alcohol (PVA/CuI) with different
concentration of CuI were obtained using casting technique.
PVA/CuI polymer composite samples have been prepared and
subjected to characterizations using FTIR spectroscopy, The FTIR
spectral analysis shows remarkable variation of the absorption peak
positions with increasing CuI concentration. The obtained results by
X-ray diffraction indicated the formation of cubic CuI particles. The
effects of CuI concentrations on the optical properties of the PVA
films were studied in the region of wavelength, (190-1100) nm.
From the derivation of Tauc's relation it was found that the direct
allowed t

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Effect of Subinhibitory concentration of Antibiotic on Bacterial Adherence to Orthopedic Prosthetic Device
...Show More Authors

The effect of subinhibitory concentration of Antibiotics on the Adherence of S.aureus (Coagulase Positive Staphylococci), and S.epidermidis (Coagulase negative Staphylococci) and Pseudomonas aeruginosa, Enterobacter cloacae, Citobacter freundi (Gram negative bacteria) was done and the results revealed that Rifampicin was the best antibiotic inhibiting Staphylococci adherence and Vancomycin has less effect on the adherence of Staphylococci, whereas Tetracyclin was the best antibiotic inhbiting Gram negative bacteria adherence and Amikacin has the lest less effect on inhibiting bacterial adherence.

View Publication Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Applied Sciences And Nanotechnology
Characterization of Prepared Polyaniline Nanofibers Based on a Hydrothermal Variation of Aniline Concentration
...Show More Authors

Polyaniline nanofibers (PAni-NFs) have been synthesized under various concentrations (0.12, 0.16, and 0.2 g/l) of aniline and different times (2h and 3 h) by hydrothermal method at 90°C. Was conducted with the use of X-ray diffraction (XRD), Fourier Transform Infrared spectra (FTIR), Ultraviolet-Visible (UV-VIS) absorption spectra, Thermogravimetric Analysis (TGA), and Field Emission-Scanning Electron Microscopy (FE-SEM). The X-ray diffraction patterns revealed the amorphous nature of all the produced samples. FE-SEM demonstrated that Polyaniline has a nanofiber-like structure. The observed typical peaks of PAni were (1580, 1300-1240, and 821 cm-1 ), analyzed by the chemical bonding of the formed PAni through FTIR spectroscopy. Also, tests

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Tue Jan 09 2018
Journal Name
World Rural Observations
Solid cartridges in Determination of Benzidines in River and Wastewater by HPLC
...Show More Authors

A solid Phase Extraction (SPE) cartridges followed by HPLC-UV method is described for the simultaneous quantitative determination of benzidine (BZ) and its substituted 3, 3’-dichlorobenzidine (DCB) and 3, 3’-Dimethylbenzidine (DMB). The Benzidines were separated by liquid chromatography using a C-18 column with UV detector at wave length of 280nm. The mode of Flow was isocratic. The mobile phase was consisted of 75:25 methanol: water, column temperature 50C°, and Flow Rate 1.8ml/min. Calibration curves were linear (R2 = 0.9979-0.9995). LOD (26.36-33.67) µg/L, LOQ (109.98-186.11) µg/L, the Robustness (2.99-4.35), Ruggedness (2.93-3.65).Conditions of extraction by (SPE) cartridges were optimized, the resin used is Octadecyl silica (ODS

... Show More
Publication Date
Tue Oct 30 2018
Journal Name
Iraqi Journal Of Physics
Determination of radioactive concentrations in Tigris river soil samples in Baghdad province
...Show More Authors

In this study, the amounts of activity concentrations of naturally occurring in 10 soil samples of the Tigris river and surrounding areas collected from deferent city of Baghdad have been investigated. Tigris river is an important water source for irrigation and drinking in Iraq. This study was done during 2018 in Protection Center of the Iraqi Ministry of Health and Environment using a high purity germanium detector. The resolution of (HPGe) at 2keV and 30% efficiency. The results of soil sample obtained showed that the effective activity concentration of 40K are ranged from 181.4 Bq/kg in sample S6 to 286.4 Bq/kg in S7. For Raeq values are ranged from 6 Bq/m3 in sample S5 to 17 Bq/m3 in sample S3. The obtained data revealed that the me

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
International Conference On Scientific Research & Innovation (icsri 2022)
Saccharomyces Cerevisiae as a human pathogen in renal transplant recipients
...Show More Authors

View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Feb 28 2021
Journal Name
Journal Of Economics And Administrative Sciences
Employ lean leadership behaviors to enhance investment in human capital
...Show More Authors

This research aims to determine the importance of the role that agile leadership plays in supporting programs and areas of investment in human capital, as it is the most important type of capital that the organization possesses and achieves returns that are many times the cost it bears, due to its rare and valuable characteristics. Through six behaviours: (humility behaviour, calm behaviour, wisdom behaviour, patience behaviour, objectivity behaviour, trust behaviour). As for investment in human capital, it was measured through its four elements (skills, knowledge, capabilities, experiences). Despite this, the researched organizations suffer from a decrease in awareness of the importance of this type of investment and the role of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Sep 30 2024
Journal Name
Malaysian Journal Of Science
DEVELOPMENT OF A SPECTROPHOTOMETRIC DETERMINATION OF PREDNISOLONE IN DIFFERENT DOSAGE FORMS
...Show More Authors

A sensitive, accurate, and affordable colorimetric method was developed for assaying prednisolone (PRZ) in various medicinal forms. The procedure involves the oxidation of PRZ by ferric ions, followed by complexation of the resulting ferrous ions with ferricyanide to produce a greenish-blue product. Common complexation conditions were thoroughly investigated. The mole ratio of FeCl₃·6H₂O to K₃Fe(CN)₆ was 8:1. The proposed mechanism of complexation was suggested and considered. Various parameters were optimized, including the reduction of the colorimetric reaction temperature to 50°C and the duration of heating and analysis to 20-30 minutes. The calibration curve was linear over the range of 1-60 µg/mL. The limit of detection (LOD

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 02 2011
Journal Name
Al-khwarizmi Engineering Journal
Biomechanical Concept Design of Artificial Human Hand
...Show More Authors

This work is focused on the design parameters and activity of artificial human finger for seven grips. At first, obtained the ideal kinematics of human fingers motion by analyzing the grips video which were recorded using a single digital camera recorder fitted on a tripod in sagital plane while the hand is moving. Special motion analysis software (Dartfish) the finger joint angles were studied using the video recording. Then the seven grips were modeled using static torque analysis, which calculates the amount of torque applied on the fingers joint grip depending on the results of the kinematic analysis. The last step of the work was to design the actuator (Muscle Wire) of artificial finger for the seven grips in a simple design approac

... Show More
View Publication Preview PDF