In this study, the activity concentrations of indoor radon, thoron
and their progeny have been measured in air for 61 different
locations of Al-Maddan city using twin cup dosimeter. Furthermore,
some useful parameters concerning the health hazards have been
estimated; working level month (WLM), annual effective dose (Eff),
and excess lung cancer per million person per year (ELC).The results
show that the values of radon gas levels in the investigated districts
varied from 56.28 to 194.43Bq/m3with an overall average value
132.96Bq/m3, while 0.313 to 1.085 for WLM with an overall average
0.740, respectively. The value of Eff and ELC have been found to
vary from 1.420 to 4.918 mSv/y with an overall average value
3.354mSv/y, and 852 to 2951 with an overall average value 2013,
respectively. For thoron gas only, the results showed that the thoron
activity concentration varied from 15.05 to 172.40 Bq/m3 with an
overall average 76.48 Bq/m3, and 0.021to 0.240for WLM with an
overall average 0.106, respectively. The values of Eff and ELC have
been found to vary from 0.256 to 2.94 mSv/y with an overall
average1.30 mSv/y and from 57 to 652 with an overall average of
298, respectively. The concentration of radon progeny varied from
59.44 to 301.39 Bq/m3 with an overall average 157.62 Bq/m3. The
results illustrated that there is a large variation in the values of the
measured concentrations. This is due to the wide variation in the
construction of the houses in Al-Madaan city. However, all
investigated locations have radon concentration below the action
level (200-300Bq/m3) that recommended byICRP. Therefore, there is
no health hazard of radon in the region of Al-Madaan city where
measurements have been performed.
POSSIBILITY OF APPLICATION THE BALANCED SCORECARD IN THE IRAQI INDUSTRIAL COMPANIES: A PROPOSED MODEL
Verbs in German and Arabic are of two types: active and passive. Passive voice is a grammatical voice construction that is found in many languages. Out of grammatical perspective, each main verb has a form in the active and one in the passive known as a "genus verbi" (type of verb). In passive voice, both in German and in Arabic, the focus is on the action itself or on the result of the action; often the perpetrator is not mentioned. In German, to conjugate verbs in the passive voice, you must know the forms of werden (to become). German uses werden + the past participle and states it at the end of a sentence. In Arabic,
... Show MoreStraight tendons in pretensioned members can cause high-tensile stresses in the concrete extreme fibers at end sections because of the absence of the bending stresses due to self-weight and superimposed loads and the dominance of the moment due to prestressing force alone. Accordingly, the concrete tensile stresses at the ends of a member prestressed with straight tendons may limit the service load capacity of the member. It is therefore important to establish limiting zone in the concrete section within which the prestressing force can be applied without causing tension in the extreme concrete fibers. Two practical methods are available to reduce the stresses at the end sections due to the prestressing force. The first method based
... Show MoreThis research dealt with shedding light on the nature of material misrepresentations, in addition to knowing the extent to which the quality of accounting information systems contributes to reducing material misrepresentations On the theoretical side, a number of sources were relied upon in dealing with the research problem and presentation of the topic, while in the practical side, it was relied on the questionnaire form, where the research sample was (accountants and auditors), where 50 forms were distributed and 50 were received, and the data was analyzed and hypotheses tested through the program Statistical spss to show the relationship between the variables. The research reached a number of conclusions, the most important of which is t
... Show More(3) (PDF) Theoretical calculation of the electronic current at N3 contact with TiO2 solar cell devices. Available from: https://www.researchgate.net/publication/362780274_Theoretical_calculation_of_the_electronic_current_at_N3_contact_with_TiO2_solar_cell_devices [accessed May 01 2023].
The current research aims to describe the level of responsiveness and awareness of the officials of the General Company for Construction Industries to the indicators of the blue market strategy of (1. reduction 2. exclusion 3. increase 4. innovation) and the degree of prioritization according to their importance as well as the differences in the responses of the sample investigated according to the personal variables. As a main tool in the collection of data from the sample, which consisted of(34) officers (Associate, Manager, Section Manager, Division Officer) in the company being investigated, and computed mean, standard deviations, percentage weights,and test (x2 ) based on the SPSS. The research reached the following
... Show MoreAbstract: Reflection optical fibre Humidity sensor is presented in this work, which is based on no core fibre prepared by splicing a segment of no core fibre (NCF) at different lengths 1-6 cm with fixed diameter 125 µm and a single mode fibre (SMF). The range of humidity inside the chamber is controlled from 30% to 90% RH at temperature ~ 30 °С. The experimental result shows that the resonant wavelength dip shift decreases linearly with an increment of RH% and the sensitivity of the sensor increased linearly with an increasing in the length of NCF. However, a high sensitivity 716.07pm/RH% is obtained at length 5cm with good stability and reputability. Furthermore, the sensor is shif
... Show MoreThe catalytic cracking of three feeds of extract lubricating oil, that produced as a by-product from the process of furfural extraction of lubricating oil base stock in AL-Dura refinery at different operating condition, were carried out at a fixed bed laboratory reactor. The initial boiling point for these feeds was 140 ºC for sample (1), 86 ºC for sample (2) and 80 ºC for sample (3). The catalytic cracking processes were carried out at temperature range 325-400 ºC and initially at atmospheric pressure after 30 minutes over 9.88 % HY-zeolite catalyst load. The comparison between the conversion at different operating conditions of catalytic cracking processes indicates that a high yield was obtained at 375°C, according to gasoline pr
... Show MoreThe aim of this paper is to present a new methodology to find the private key of RSA. A new initial value which is generated from a new equation is selected to speed up the process. In fact, after this value is found, brute force attack is chosen to discover the private key. In addition, for a proposed equation, the multiplier of Euler totient function to find both of the public key and the private key is assigned as 1. Then, it implies that an equation that estimates a new initial value is suitable for the small multiplier. The experimental results show that if all prime factors of the modulus are assigned larger than 3 and the multiplier is 1, the distance between an initial value and the private key
... Show More