Preferred Language
Articles
/
ijp-164
Determination the concentrations of radon gas and exhalation rate in some phosphate fertilizer using CR-39 track detector
...Show More Authors

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 02 2014
Journal Name
Baghdad Science Journal
Exploiting the diazotization reaction of 4- minoacetophenone for Methyldopa determination.
...Show More Authors

Based on the diazotization reaction of 4-aminoacetophenone with sodium nitrite in acid medium to form diazonium salt, which was coupled with Methyldopa to form a violet reddish soluble azo dye with maximum absorbance at 560 nm,a batch procedure had been developed for the estamination of Methyldopa. Under optimum experimental parameters affecting on the development and stability of the colored product, Beer´s law obeyed in the range (0.5-45) ?g.ml-1 with a correlation coefficient (0.9979).The proposed method was successfully applied to the determination of Methyldopa in either pure form and in commercial brands of pharmaceuticals, no interference was observed from common excipients in the formulations. The analytical results obtained by app

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Determination The Effect of ZnO on Iraqi Bentonite Surface Properties
...Show More Authors

Bentonite is widely used in industrial applications. The present study reports the effect of adding different weights of ZnO to the Iraqi bentonite, on surface area, pore volume and real density. These surface properties were evaluated for pure and modified bentonite. The modification was made by adding different ZnO weights such as; ( 0.5%, 1%, 5%, 10% ). The effect of heat exposing for all modified clay samples at 500 ?C have been also evaluated. The results show that the addition of 0.5% ZnO leads to increase the surface area percentage about 36%, increase pore volume percentage about 5.48% and increase the real density percentage about 27.116%. When the samples exposed to 500 ?C, their surface area and pore volumes have been decreased a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
CFIA-Turbidimetric and Photometric Determination of Vitamin B9 (Folic acid) Using LEDs as a Source of Irradiation and Two Solar Cells as an Energy Transducer
...Show More Authors

A specific, sensitive and simple method was used for the determination of: vitamin B9 (Folic acid) in pure and pharmaceutical formulations using continuous flow injection analysis. The method is based on formation of ion pair compound between folic acid and ammonium molybdate in an aqueous medium to obtain a gray precipitate complex, using homemade; Ayah-6SX1-ST-2D solar cell CFI Analyzer. Optimum parameters was studied to increase the sensitivity for developed method. The linear range for the calibration graph was 0.01-0.6 mMol.L-1 of vitamin B9 and LOD was 131.994 ng/sample with correlation coefficient ( r ) of 0.9810, RSD% was lower than 0.1%, (n=9) for the determination of vitamin B9 at concentration (0.07and 0.5) mMol.L-1 respectiv

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Tue Oct 01 2013
Journal Name
International Journal Of Biological Macromolecules
Characterization and determination of lignin in different types of Iraqi phoenix date palm pruning woods
...Show More Authors

View Publication
Scopus (24)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Sun Aug 30 2020
Journal Name
Turkish Journal Of Agriculture - Food Science And Technology
Determination of Operating Characteristics of 540 and 540E PTO Applications in Disc Type Silage Machines
...Show More Authors

In this study, performance characteristics such as power take off (PTO) power consumption, fuel consumption, fuel consumption for the unit field-unit product were determined at different working speeds with two different PTO applications (540 and 540E) in a single row disc type silage machine. In particular, the 540E PTO application greatly reduces fuel consumption for unit work. The best results in terms of hourly fuel consumption were achieved in 540E PTO application and V1 working speed. When the field - product fuel consumption is evaluated, the best results were obtained with the 540E PTO application at the V3 working speed. When an evaluation is made considering all the parameters, it is concluded that the 540E PTO application will p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Waterpipe Smoking Effect on Clinical Periodontal Parameters, Salivary Flow Rate and Salivary pH in Chronic‎ Periodontitis Patient
...Show More Authors

Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Micro Amount of Chromium (III) Using Sodium 4-((4,5-diphenyl-imidazol-2-yl)diazenyl)-3-hydroxynaphthalene-1-sulfonate in the Presence of Surfactant, Study of Thermodynamic Functions and Their Analytical Applications
...Show More Authors

          Using sodium4-((4,5-diphenyl-imidazol-2-yl)diazenyl)-3-hydroxynaphthalene-1-sulfonate (SDPIHN) as a chromogenic reagent in presence of non-ionic surfactant (Triton x-100) to estimate the chromium(III)  ion if the wavelength of this reagent 463 nm to form a dark greenish-brown complex in wavelength 586 nm at pH=10,the complex was stable for longer than 24 hours. Beer's low, molar absorptivity 0.244×104L.mol-1.cm-1, and Sandal's sensitivity 0.021 µg/cm2 are all observed in the concentration range 1-11 µg/mL. The limits of detection (LOD) and limit of quantification (LOQ), respectively, were 0.117 µg/mL and 0.385µg/mL. (mole ratio technique, job's method) were employed to

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Wed May 19 2010
Journal Name
Journal Of College Of Science, University Of Babylon
H-Point Standard Addition Method for Simultaneous Determination of Cimetidine and Erythromycin Ethylsuccinate Drugs Using Bromothymol Blue as a Chromogenic Complexing Agent
...Show More Authors

The H-Point Standard Addition Method (H-PSAM) has been applied for spectrophotometric simultaneous determination of Cimetidine and Erythromycin ethylsuccinate using Bromothymol Blue (BTB) as a chromogenic complexing agent in a buffer solution at pH 5.5.

Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Preparation and Characterization of Bimetallic Catalyst (NiO – CoO) for Desulfurization of Gas Oil
...Show More Authors

In this study NiO - CoO bimetallic catalysts are prepared with two Ni/Co ratios (70:30 and 80: 20) using the precipitation method of nitrate salts. The effects of Ni /Co ratio and preparation methods on the catalyst are analyzed by using different characterization techniques, i.e. atomic absorption (AA) , XRD, surface area and pore volume measurements according to the BET method . The results indicate that the best catalyst is the one containing the percentage of Ni :Co ( 70 : 30 ). Experiments indicate that the optimal conditions to prepare catalyst are stirring for three hours at a temperature of 60oC of the preparation , pH= (8-9) , calcination temperature at 400oC for two hours

... Show More
View Publication Preview PDF
Crossref