The present work intends to study of dc glow discharge were generated between pin (cathode) and a plate (anode) in Ar gas is performed using COMSOL were used to study electric field distribution along the axis of the discharge and also the distribution of electron density and electron temperature at constant pressure (P=.0.0mbar) and inter electrode distance (d=4 cm) at different applied voltage for both pin cathode system and plate anode and comparison with experimental results.
In this work, we are obviously interested in a general solution for the calculation of the image of a single bar in partially coherent illumination. The solution is based on the theory of Hopkins for the formation of images in optical instruments in which it was shown that for all practical cases, the illumination of the object may be considered as due to a self – luminous source placed at the exit pupil of the condenser , and the diffraction integral describing the intensity distribution in the image of a single bar – as an object with half – width (U0 = 8 ) and circular aperture geometry is viewed , which by suitable choice of the coherence parameters (S=0.25,1.0.4.0) can be fitted to the observed distribution in various types of mi
... Show MoreIron , Cobalt , and Nickel powders with different particle sizes were subjected to sieving and He-Ne laser system to determine the particle size . 1wt% from each powders was blended carefully with 99wt% from Iraqi oil . Microscopic examination were carried for all samples to reveal the particle size distribution . A Siemens type SRS sequential wavelength dispersive(WDS) X-ray spectrometer was used to analyze all samples , and the XRF intensity were determined experimentally and theoretically for all suspended samples , Good agreement between theoretical and experimental results were found .
Background: A Temporomandibular joint (TMJ) internal derangement (TMJID) is a disruption within the internal aspects of the TMJ in which the disc is displaced from its normal functional relationship with the mandibular condyle, after which the articular portion of the temporal bone causes joint dysfunction, joint sound, malocclusion, and locking of the mouth. Conservative and invasive techniques can be used for the treatment of TMJID. A platelet-rich plasma (PRP) injection is a simple, less invasive surgical procedure for the treatment of internal derangement. The objective of this study was to evaluate the efficacy of PRP injections in decreasing or eliminating pain, clicking, and limitation of mouth opening in patients with TMJID after th
... Show MoreThis study illustrates effect of cold plasma CAP on the mineral blood components in vivo. the mineral blood component (Ca, Na, Cl, K and Fe) are used. Floating Electrode-Dielectric Barrier Discharge (FE-DBD) system of probe diameter 4cm is used for this purpose, and variable voltage (0-20) kV and variable frequency (0-30) kHz, the output power was ranged from (10 - 70) W. the effect of cold atmospheric plasma on mineral blood is studied with different exposure durations (30,45,60) sec. As the plasma exposure duration increases, the calcium, potassium and iron components in the blood increased, while The sodium and chlorine elements decreased. These results give an indication of the cold plasma receptor to be used to treat many disea
... Show MoreFractal image compression gives some desirable properties like fast decoding image, and very good rate-distortion curves, but suffers from a high encoding time. In fractal image compression a partitioning of the image into ranges is required. In this work, we introduced good partitioning process by means of merge approach, since some ranges are connected to the others. This paper presents a method to reduce the encoding time of this technique by reducing the number of range blocks based on the computing the statistical measures between them . Experimental results on standard images show that the proposed method yields minimize (decrease) the encoding time and remain the quality results passable visually.
The aim of this work is to design an algorithm which combines between steganography andcryptography that can hide a text in an image in a way that prevents, as much as possible, anysuspicion of the hidden textThe proposed system depends upon preparing the image data for the next step (DCT Quantization)through steganographic process and using two levels of security: the RSA algorithm and the digitalsignature, then storing the image in a JPEG format. In this case, the secret message will be looked asplaintext with digital signature while the cover is a coloured image. Then, the results of the algorithmare submitted to many criteria in order to be evaluated that prove the sufficiency of the algorithm andits activity. Thus, the proposed algorit
... Show More