Preferred Language
Articles
/
ijp-117
Effect of plasma jet on the water and hydrogen peroxide that used for assisted teeth bleaching
...Show More Authors

In this work the interaction of plasma jet with water and hydrogen peroxide liquids used for assisted teeth bleaching by plasma jet had been study. A homemade plasma jet system was used. The plasma jet supply by 15 W electrical power generated by high voltage power supply of 9.6 kV peak to peak and frequency of 33 kHz .this power supply generate high electric field on electrodes that would be enough to ionize the argon gas. Some important agents were study such as the effect of the Ar gas flow rates on the length of the plasma jet, the influence of plasma jet on some properties of water and two hydrogen peroxide concentrations 25 % and 30 % like pH, conductivity and liquid temperature for different exposure time. The liquids temperature was measured by digital infrared thermometer, the gas flow rate were measured by gas flow meter, the pH, and the conductivity was measured by pH conductivity ultra-meter. The results illustrated that the conductivity and liquid temperature increase with increasing of exposure time. It can be conclude that the liquid properties were changed less than the boundaries that could affect adversely to the cells that located in the plasma jet.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 02 2018
Journal Name
Iraqi Journal Of Physics
Optical emission spectroscopy for studying the exploding copper wire plasma parameters in distilled water
...Show More Authors

This work aims to study the exploding copper wire plasma parameters by optical emission spectroscopy. The emission spectra of the copper plasma have been recorded and analyzed The plasma electron temperature (Te), was calculated by Boltzmann plot, and the electron density (ne) calculated by using Stark broadening method for different copper wire diameter (0.18, 0.24 and 0.3 mm) and current
of 75A in distilled water. The hydrogen (Hα line) 656.279 nm was used to calculate the electron density for different wire diameters by Stark broadening. It was found that the electron density ne decrease from 22.4×1016 cm-3 to 17×1016 cm-3 with increasing wire diameter from 0.18 mm to 0.3 mm while the electron temperatures increase from 0.741 to

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Engineering
Evaluation of Fatigue Behavior of Epoxy Coatings used for Potable Water Storage Tanks
...Show More Authors

In this paper, three types of epoxy-based coatings (Polyamide, pure Polyamine, and Polyamine reinforced by glass-flake) used as a lining for potable water tanks were studied using experimental and finite element methods. Tensile, impact, and fatigue tests were conducted on uncoated and coated AISI 316 stainless steel. The test results show that the applied epoxy based coating improves the mechanical properties, increases of fatigue crack resistance, and enhance the dynamic fracture toughness. The fatigue crack propagation is influenced by the compositions of epoxy coating, and the glass-flake improves the coating resistance to fatigue crack propagation compared to other types.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Biochemical & Cellular Archives
TOXOPLASMOSIS, DIABETES AND SOME IMMUNE FACTORS THAT EFFECT ON THE BURDEN OF PATIENTS’ IMMUNITY
...Show More Authors

Scopus (1)
Scopus
Publication Date
Mon Jan 01 2024
Journal Name
Dental Hypotheses
Effect of Surface Treatments with Plasma and Chemical Bond on Shear Bond Strength of Acrylic Denture Teeth to Flexible and Heat-Cured Denture Base Material: An In Vitro Study
...Show More Authors

Introduction: We aimed to evaluate the shear bond strength of acrylic denture teeth to flexible and heat-cured denture base material after surface treatments with argon plasma, chemical bonding agent (PALFIQUE universal), and combination. Methods: A total of 80 incisor acrylic denture teeth were treated with a argonplasma, chemical bond (PALFIQUE universal bond), and a combination with 10 samples for each group. The neck (gingival portion) of teeth was cut at a 45° angle, and the teeth were attached to heat-cured acrylic resin and flexible denture base material. All the specimens were stored in artificial saliva for 7 days in an incubator (37 °C). A shear

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Mon Mar 11 2019
Journal Name
Baghdad Science Journal
Study the Effect of Cold Plasma on the Nonlinear Properties of Polymeric Membranes Rod Amine (R3Go)
...Show More Authors

The nonlinear optical properties for polymeric (PMMA) doping with dye Rhodmine (R3Go) has been studied .The samples are prepared by normal polymerization method with concentrations of 5x10-5mol/l and a thickness of 272.5µm.

                         Plasma effect was studied on samples prepared before and after exposure to the Nd: YAG laser for three times 5, 10 and 15 minutes. Z-Scan technique is used to determine the nonlinear optical properties such as; refractive index (n2) and the coefficient of nonlinear absorption (β). It was found that the nonlinear properties is change by increasi

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Effect of Cold Atmospheric Pressure Plasma on Fertility Hormones for Female Rats
...Show More Authors
Abstract<p>The direct application of cold atmospheric plasma (CAP) is the main scope of plasma medicine in or on the organism for curative purposes. Cold plasma is both effective in disrupting a wide range of microorganisms including multiple drug resistant ones (MDRs) and to stimulate proliferation of mammalian cells. It has obtained by Floating Electrode Dielectric Barrier Discharge (FE-DBD) system. The present study aimed to show the effected of cold plasma on the fertility hormones LH, Prolactin, Estrogen, and Testosterone hormones for healthy adult female rats (Albino) / bulb c). There are divided into many groups according to time exposure of plasma (15, 30, 60, and 90 second) and a refere</p> ... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 03 2024
Journal Name
Revista Brasileira De Engenharia AgrĂ­cola E Ambiental
Effect of cold plasma technique on the quality of stored fruits - A case study on apples
...Show More Authors

The consumption of fresh fruits has increased nowadays due to the lifestyle of the consumers. Maintaining the quality and nutritional value of cut fruits during storage is difficult compared to whole fruits. Deterioration of internal and external quality usually occurs in freshly harvested fruits. It is necessary to use different techniques to maintain the quality and increase the shelf life of the freshly cut product. This research studied the effect of treating apple slices with cold plasma once and with filtered water again on quality characteristics (hardness, moisture content, sugar content, carbohydrate content, and color) after being stored for five days. The best treatment was determined using two different pressures of the plasma j

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Immiscible CO2-Assisted Gravity Drainage Process for Enhancing Oil Recovery in Bottom Water Drive reservoir
...Show More Authors

The CO2-Assisted Gravity Drainage process (GAGD) has been introduced to become one of the mostinfluential process to enhance oil recovery (EOR) methods in both secondary and tertiary recovery through immiscibleand miscible mode. Its advantages came from the ability of this process to provide gravity-stable oil displacement forenhancing oil recovery. Vertical injectors for CO2 gas have been placed at the crest of the pay zone to form a gas capwhich drain the oil towards the horizontal producing oil wells located above the oil-water-contact. The advantage ofhorizontal well is to provide big drainage area and small pressure drawdown due to the long penetration. Manysimulation and physical models of CO2-AGD process have been implemented

... Show More
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Effect of Hydroxyapatite Coatings on Corrosion Behavior for Biotype 316L SS Used in Orthopaedic Applications
...Show More Authors

Electrochemical corrosion of hydroxyapatite (HAP) coated performance depends on various parameters like applied potential, time, thickness and sintering temperature. Thus, the optimum parameters required for the development of stable HAP coatings was found by using electrophoretic deposition (EPD) technique. This study discusses the results obtained from open circuit potential-time measurements (OCP-time), potentiodynamic polarisation and immersion tests for all alloy samples done under varying experimental conditions, so that the optimum coating parameters can be established. The ageing studies of the coated samples were carried out by immersing them in Ringer’s solution for a period of 30 days indicates the importance of stable HAP c

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
New Method for the On-Line Determination of Molybdenum Via New Microphotometric Home Mode Instrument, Using Hight Emitting Diode as a Variable Intensity Radiant Source with a Miniture Photosilicone Diode Detector for System: Molybdenum(VI)-Hydrogen Peroxide-Ammonium Solution
...Show More Authors

This research work aims to the determination of molybdenum (VI) ion via the formation of peroxy molybdenum compounds which has red-brown colour with absorbance wave length at 455nm for the system of ammonia solution-hydrogen peroxide-molybdenum (VI) using a completely newly developed microphotometer based on the ON-Line measurement. Variation of responses expressed in millivolt. A correlation coefficient of 0.9925 for the range of 2.5-150 ?g.ml-1 with percentage linearity of 98.50%. A detection limit of 0.25 ?g.ml-1 was obtained. All physical and chemical variable were optimized interferences of cation and anion were studied classical method of measurement were done and compared well with newly on-line measurements. Application for the use

... Show More
View Publication Preview PDF
Crossref