Preferred Language
Articles
/
ijp-1148
Characterization of Magnetized-Plasma System Induced by Laser
...Show More Authors

  This study investigated the effect of applying an external magnetic field on the characteristics of laser-induced plasma, such as its parameters plasma, magnetization properties, emission line intensities, and plasma coefficients, for plasma induced from zinc oxide: aluminum composite (ZO:AL) at an atomic ratio of 0.3 %. Plasma properties include magnetization and emission line intensities. The excitation was done by a pulsed laser of Nd:YAG with 400 mJ energy at atmospheric pressure. Both the electron temperature and number density were determined with the help of the Stark effect principle and the Boltzmann-Plot method. There was a rise in the amount of (ne) and (Te) that was produced by applying a magnetic field and, on the other hand, using the 532 nm wavelength rather than the fundamental wavelength of a laser. The emission lines in the atmosphere's plasma have an appearance of Lorentzian shape. The 532 nm laser exhibited a decrease in both the Larmor radius and the confinement factor compared with the 1064 nm laser. By applying the magnetic field, the Laser Induced Breakdown Spectroscopy (LIBS) intensities increased by 1.44 times when compared to the emissions before applying the field. In addition, the spectral line intensities improved with the fundamental wavelength compared to the second harmonic frequency as a result of the increase in the extracted materials. This is due to the increase in the absorbance of the laser by the target, as some of these materials are excited, so they act as emission sources, which makes them more detectable.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Apr 06 2024
Journal Name
Indian Journal Of Physics
Investigating the effect of alternating voltage frequency on plasma jet parameters
...Show More Authors

View Publication
Scopus (1)
Scopus
Publication Date
Wed Mar 01 2023
Journal Name
Baghdad Science Journal
Traveling Wave Solutions of Fractional Differential Equations Arising in Warm Plasma
...Show More Authors

This paper aims to study the fractional differential systems arising in warm plasma, which exhibits traveling wave-type solutions. Time-fractional Korteweg-De Vries (KdV) and time-fractional Kawahara equations are used to analyze cold collision-free plasma, which exhibits magnet-acoustic waves and shock wave formation respectively. The decomposition method is used to solve the proposed equations. Also, the convergence and uniqueness of the obtained solution are discussed. To illuminate the effectiveness of the presented method, the solutions of these equations are obtained and compared with the exact solution. Furthermore, solutions are obtained for different values of time-fractional order and represented graphically.

View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
The role of atmospheric non-thermal plasma in the bacteria inactivation
...Show More Authors

Non-thermal atmospheric pressure plasma has emerged as a
new promising tool in medicine and biology. In this work, A DBD
system was built as a source of atmospheric pressure non-thermal
Plasma suitable for clinical and biological applications. E. coli and
staphylococcus spp bacteria were exposed to the DBD plasma for a
period of time as inactivation (sterilization) process. A series of
experiments were achieved under different operating conditions. The
results showed that the inactivation, of the two kinds of bacteria, was
affected (increasing or decreasing) according to operation conditions
because they affects, as expected, the produced plasma properties
according to those conditions.

View Publication Preview PDF
Crossref
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Impedance Characteristics of Pulsed Atmospheric Electrical Discharge in Spherical Plasma Switch
...Show More Authors

A number of pulsed experiments have been carried out using a high-voltage circuit containing R,L, and C in certain arrangements. A spherical spark gap of steel electrodes was used as a high-current switch operated by a voltage of up to 8kV and triggered in both self-triggering and third-electrode triggering modes. Current measurements were carried out by using both current-viewing resistor and Rogowski coils designed for this purpose. Typical current waveforms have shown obvious dominating inductance effect of the circuit components in an underdamped oscillation. The behavior of the circuit impedance was studied by recording both pulsed current peaks and the charging voltages when currents of up to 2.5kA were recorded. The dur

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
The effect of plasma jet-generated gold nanoparticles on liver functions
...Show More Authors

In this study, gold nanoparticles (AuNPs) were synthesized using a plasma jet system at different exposure times. Using ultraviolet, visible spectra, X-ray diffraction, the nanoparticles were characterized (XRD). A Plasmon surface resonance concentrated at 530, 540, and 533 nm for the prepared AuNPs. The pattern of XRD showed that the extreme peaks of the film reflect crystalline existence. The face-centered cubic structure of the gold nanoparticles was prepared for all samples, with an average crystallite size of 25-40 nm. The effect of AuNPs in vivo on liver function levels was measured. For all doses, we notice an increase in the ranks of liver function in the blood during the period of dosing, and it begins to decrease when the dosi

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Aug 29 2016
Journal Name
Kufa Journal For Nursing Sciences
Atherogenic Index of Plasma Levels in Patients with Diabetic and Neurodiabetic
...Show More Authors

Objectives: To determined the levels of lipid profile (TC, TG, HDL-c, LDL-C, VLDL) in diabetic and diabetic neuropathy patients and compare the results with control group. Also, to compare Atherogenic Index of Plasma (AIP) levels in these groups that may be predict prone of patients to cardiovascular disease. Methodology: Ninety subjects were enrolled in this study with aged ranged (40-65) years and BMI with (30-35) Kg/m2 that divided into three groups as follows: group one (G1) consists of 30 healthy individuals as a control group, group two (G2) consists of 30 patients with diabetes and group three (G3) consists of 30 patients with diabetes and neuropathy as complication. Electrochemical Skin Conductance (Feet Mean), Electrochemic

... Show More
View Publication
Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Simulation and experimental study of Pin-Plate DC discharge plasma technique
...Show More Authors

The present work intends to study of dc glow discharge were generated between pin (cathode) and a plate (anode) in Ar gas is performed using COMSOL were used to study electric field distribution along the axis of the discharge and also the distribution of electron density and electron temperature at constant pressure (P=.0.0mbar) and inter electrode distance (d=4 cm) at different applied voltage for both pin cathode system and plate anode and comparison with experimental results.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Sep 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Corrosion Parameters for a Cathodic Reaction Complicated by IR Drop Effect in a Flow System
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Case Studies In Chemical And Environmental Engineering
Treatment of petroleum refinery wastewater by an innovative electro-Fenton system: Performance and specific energy consumption evaluation
...Show More Authors

View Publication
Scopus (11)
Crossref (12)
Scopus Crossref
Publication Date
Wed May 31 2017
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
THE EFFECT OF ALCOHOLIC EXTRACT OF ANETHUM GRAVEOLENS IN ALLOXAN INDUCED DIABETIC RATS.: THE EFFECT OF ALCOHOLIC EXTRACT OF ANETHUM GRAVEOLENS IN ALLOXAN INDUCED DIABETIC RATS.
...Show More Authors

Active compounds were extracted from Anethum gravoelens to produce safety vegetable treat for diabetic, the results showed that alcoholic extract of Anethum gravoelens contain Alkaloid, glycosides, phenols, resins, saponins, coumarins, flavonoide, terpenes, steroids and volatile oils. after that it was studied the effect of alcoholic extract at dose 50, 100 mg/kg of body weight in reduced glucose level in serum of diabetic rats induced by alloxan, after the end of experiment for period 30 days the rats fasting 12 hours to measure the level of glucose in serum, the result showed asignificant decrease in serum glucose level of rats treated with extract in comparison with positive group (alloxan), So biochemical tests showed significant dec

... Show More
View Publication Preview PDF