Preferred Language
Articles
/
ijp-1130
Study of the Structural, Optical, and Morphological Properties of SnO2 Nanofilms under the Influence of Gamma Rays
...Show More Authors

This study reports the fabrication of tin oxide (SnO2) thin films using pulsed laser deposition (PLD). The effect of 60Co (300, 900, and 1200 Gy) gamma radiation on the structural, morphological, and optical features is systematically demonstrated using X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), atomic force microscopy (AFM), and ultraviolet-visible light analysis (UV-Vis), respectively In XRD tests, the size of the crystallites decreased from 45.5 to 40.8 nm for the control samples and from 1200 Gy to 60Co for the irradiated samples. Using FESEM analysis, the particle diameter revealed a similar trend to that attained using XRD; in particular, the average diameters were 93.8 and 79.9 nm for the samples mentioned above. A similar profile was observed for the AFM analysis in which an increase in the radiation dose from 300 to 1200 Gy resulted in a decrease in the RMS values from 74.6 to 32.25 nm. Contrariwise, the calculated optical band gap demonstrated an increasing profile where optical band gaps of 3.08 and 3.18 eV were acquired for control and samples irradiated with 900 Gy. However, the attained optical band gap was further increased to 3.24 eV due to the 60Co gamma radiation increment to 1200 Gy.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 16 2018
Journal Name
Design And Manufacture An Automatic Knife For Date Palm Tree Frond Cutting Operates By Frequency Theory Cutting‏ Mra Abdulrazak A. Jasim‏
Design and manufacture an automatic knife for date palm tree frond cutting Operates by frequency theory Cutting‏
...Show More Authors

Publication Date
Fri Dec 20 2019
Journal Name
Iet Circuits, Devices & Systems
Multi‐bit error control coding with limited correction for high‐performance and energy‐efficient network on chip
...Show More Authors

In the presence of deep submicron noise, providing reliable and energy‐efficient network on‐chip operation is becoming a challenging objective. In this study, the authors propose a hybrid automatic repeat request (HARQ)‐based coding scheme that simultaneously reduces the crosstalk induced bus delay and provides multi‐bit error protection while achieving high‐energy savings. This is achieved by calculating two‐dimensional parities and duplicating all the bits, which provide single error correction and six errors detection. The error correction reduces the performance degradation caused by retransmissions, which when combined with voltage swing reduction, due to its high error detection, high‐energy savings are achieved. The res

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Aug 08 2022
Journal Name
Egyptian Journal Of Chemistry
Synthesis, Characterization, Spectroscopic, Thermal and Biological Studies for New Complexes with N1, N2-bis(3-hydroxyphenyl) Oxalamide
...Show More Authors

View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Journal Of Pakistan Association Of Dermatologists
Zinc as an essential element for normal immune reactions and as a therapeutic agent for autoimmune diseases
...Show More Authors

Scopus (1)
Scopus
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Relationship between very low birth weight neonates and increased neonatal mortality for age 0 to 7 days
...Show More Authors

Background: Very low birth weight (VLBW) neonates constitute approximately 4–7 percent of all live births and their mortality is very high.
Objective: to find out if there is a relationship between Very Low Birth Weight Neonates and increased neonatal mortality for age 0 to 7 days.
Methods: A retrospective study of VLBW neonates admitted to NICU at Ibn Al- Baladi Pediatrics and Maternity hospital over one year (2012)were studied, The study period was from April till August 2013. Exclusion criteria were: (1) neonates weighing less than 700 g and with gestational age less than 24 weeks (abortion) (2) death in the delivery room (3) neonates weighing more than 1500 g. (4) Postnatal age more than 7 days. The outcome measure was in-hos

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Pharmacy And Bioallied Sciences
Correlation between Neonatal Outcomes and Maternal Anemia among Attending Pregnant Women in Al-Elwiya Maternity Teaching Hospital
...Show More Authors
A<sc>BSTRACT</sc> <sec> <title>Background:

Anemia in pregnancy can considerably elevate the maternal mortality risk and can negatively distress the development of fetus.

Object of the Current Work:

To assess the association between neonatal outcomes and maternal anemia (MA) among pregnant women (PW).

Subjects and Methodology:

The present work is a clinical prospective one performed at Al-Elwiya Maternity

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Tue Jun 02 2020
Journal Name
International Journal Of Pharmaceutical Research
Association between Serum Leptin Level and Insulin Resistance in Acromegalic Iraqi Patients with Type 2 Diabetes Mellitus
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Mon Jul 11 2022
Journal Name
International Journal Of Online And Biomedical Engineering (ijoe)
Dynamic Background Subtraction in Video Surveillance Using Color-Histogram and Fuzzy C-Means Algorithm with Cosine Similarity
...Show More Authors

The background subtraction is a leading technique adopted for detecting the moving objects in video surveillance systems. Various background subtraction models have been applied to tackle different challenges in many surveillance environments. In this paper, we propose a model of pixel-based color-histogram and Fuzzy C-means (FCM) to obtain the background model using cosine similarity (CS) to measure the closeness between the current pixel and the background model and eventually determine the background and foreground pixel according to a tuned threshold. The performance of this model is benchmarked on CDnet2014 dynamic scenes dataset using statistical metrics. The results show a better performance against the state-of the art

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Jan 02 2019
Journal Name
Journal Of The College Of Languages (jcl)
Political Text and Its Translation into Arabic: El texto político y su traducción del español al árabe
...Show More Authors

      Field of translation is sampled with many types of translation, such as the literary, scientific, medical, etc. The translation of grammatical aspects has always been with difficulties.

Political translation is the focus here. There are many general problems faced by translators when translating political texts from Arabic into Spanish. The aim here is to clarify the definition of functions or terms within the text, and to arrive at the correct from of translation of such texts from Spanish into Arabic.  It is worth mentioning that the paper is of two parts: the first exemplifies what is meant by translation, the prerequisites of a translator, along with mentioning the methods followed&nbs

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Emulsion Liquid Membrane for Pesticides Removal from Aqueous Solution: Emulsion Stability, Extraction Efficiency and Mass Transfer Studies
...Show More Authors

The current study investigated the stability and the extraction efficiency of emulsion liquid membrane (ELM) for Abamectin pesticide removal from aqueous solution. The stability was investigated in terms of droplet emulsion size distribution and emulsion breakage percent. The proposed ELM included a mixture of corn oil and kerosene (1:1) as a diluent, Span 80 (sorbitan monooleate) as a surfactant and hydrochloric acid (HCl) as a stripping agent without utilizing a carrier agent. Parameters such as homogenizer speed, surfactant concentration, emulsification time and internal to organic volume ratio (I/O) were evaluated. Results show that the lower droplet size of 0.9 µm and higher stable emulsion in terms of breakage percent of 1.12 % we

... Show More
View Publication Preview PDF
Crossref (2)
Crossref