The electronic characteristics, including the density of state and bond length, in addition to the spectroscopic properties such as IR spectrum and Raman scattering, as a function of the frequency of Sn10O16, C24O6, and hybrid junction (Sn10O16/C24O6) were studied. The methodology uses DFT for all electron levels with the hybrid function B3-LYP (Becke level, 3-parameters, Lee–Yang-Parr), with 6-311G (p,d) basis set, and Stuttgart/Dresden (SDD) basis set, using Gaussian 09 theoretical calculations. The geometrical structures were calculated by Gaussian view 05 as a supplementary program. The band gap was calculated and compared to the measured values. The density of state of the hybrid junction (Sn10O16/C24O6) increased because of the increased number of degeneracy states. Theoretical values of bonds for C=C, C=O, and Sn-O are equal to 1.33, 1.20 and 2.27 Å respectively, these bonds values are in good agreement with experimental values of bond length of 1.34 for the C=C bond, 1.23 for the C=O bond, and 2.3 for the Sn-O bond. . The spectroscopic properties, such as IR spectra have shown a peak which is comparable to longitudinal modes of GO and tin dioxide SnO2 at (1582 and 690) cm-1, respectively.
Enhancement of the performance for hybrid solar air conditioning system was presented in this paper. The refrigerant temperature leaving the condenser was controlled using three-way valve, this valve was installed after the compressor to regulate refrigerant flow rate towards the solar system. A control system using data logger, sensors and computer was proposed to set the opening valve ratio. The function of control program using LabVIEW software is to obtain a minimum refrigerant temperature from the condenser outlet to enhance the overall COP of the unit by increasing the degree of subcooled refrigerant. A variable load electrical heater with coiled pipe was used instead of the solar collector and the storage tank to simulate the sola
... Show MoreAbstract
It is clear to everyone how important it is to implement transactions electronically, as it facilitates the provision of services to beneficiaries, whether individuals or institutions, to achieve many benefits that are not exclusive to the beneficiary or the applicant, but extends to the governmental and international bodies. And the number of users has reached millions since its emergence in 1995, because the concepts of electronic transactions have great advantages for the economy in general and the banking sector in particular, so cooperation in various fields with the aim of becoming an information society has become paramount, It allows customers to pay money to any company they want t
... Show More
Regression testing is a crucial phase in the software development lifecycle that makes sure that new changes/updates in the software system don’t introduce defects or don’t affect adversely the existing functionalities. However, as the software systems grow in complexity, the number of test cases in regression suite can become large which results into more testing time and resource consumption. In addition, the presence of redundant and faulty test cases may affect the efficiency of the regression testing process. Therefore, this paper presents a new Hybrid Framework to Exclude Similar & Faulty Test Cases in Regression Testing (ETCPM) that utilizes automated code analysis techniques and historical test execution data to
... Show MoreThis research is a continued efforts for a project on the fire tube boiler control for Al Rasheed edible oil factory. The aim is to enhance the control system with new integral control one. A functional blocks diagram (FBD) was built and simulated. With Schneider smart relays, FBD differs than ladder logic programming in which the PID option is active. An extensive work was done to understand the operation sequence, emergency shutdown, and faults causing the trips. A control program was designed to control logical sequence of operation. Furthermore temperature is controlled via cascade control with fuel and air controllers. The temperature controller output is send as remote set point to the fuel controller in a serial cascade manner. The f
... Show More