The Indian costus plasma properties are investigated including electron temperature (Te), "electron density (ne)", "plasma frequency (fp)", " Debye sphere length", and amount of Debye(Nd), using the spectrum of optical emission technique. There are several energies used, with ranging from 300 to 600 mJ. The Boltzmann Plot is used to calculate the temperature; where as Stark's Line Broadening is used to calculate the electron density. The Indian costus was spectroscopically examined in the air with the laser at 10 cm away from the target and the optical fiber at 0.5 cm away. The results were obtained for an electron temperature range of (1.8-2.2) electron volts (ev) and a wavelength range of (300-600) nm. The XRF analysis reveals that the Indian costus contains a variety of minerals, each with a different percentage, which explains why the optical emission spectrum has so many peaks. When the laser energy is (between 300 and 600 mJ) the "optical emission spectroscopy (OES) "has been used to analyze the plasma spectrum of the Indian costus in the air. The results shows that as the laser energy grew, the amount of Debye will be greater i-e (Nd) >>>1, which is one of the plasma properties.
In this research, we obtained nanoparticles (NPs) using a type of microwave (cold plasma) and water extract from Origanum vulgare with the addition of silver nitrate (AgNO3) solution. Silver nanoparticles are characterized by high production techniques. Experimental factors such as morphology, structure, optical properties and active compounds of the nanoparticle extract were studied through specific tests such as morphology, UV spectroscopy, FE-SEM, FT-IR, and Atomic Force Microscopy (AFM). Plants were used in manufacturing the nanoparticles, as plants are well known for their accessibility and applicability in different pathological areas. The current research provides information on the Green Union System of N
... Show MoreIn this research, we make an attempt to derive theoretically 1-D linear dispersion relation of ion-acoustic waves in uniform unmagnetized dusty plasma valid in the long wavelength limits. This equation matched previously special equation of acoustic modes of a general form in magnetized dusty plasma. Depending on previously mentioned experimental data, we numerically consider various parameters that affect the properties of these waves in dusty plasma. The study has shown that the presence of dust grains is to modify the properties of ion acoustic waves and affect the behavior of the plasma in which they are immersed.
In the present study, gold nanoparticles (AuNPs) were prepared using a simple low cost method synthesized cold plasma at different exposure time . The nanoparticles were characterized using UV-Visible spectra, X-ray diffraction (XRD). The prepared AuNPs showed surface Plasmon resonance centered at 530, 540,and 533 nm. The XRD pattern showed that the strong intense peaks indicate crystalline nature and face centered cubic structure of gold nanoparticles for all samples were prepared .The average crystallite size of the AuNPs was 20-40 nm. Morphology of the AuNPs were carried out using FESEM. Observations show that the AuNPs synthesized we well dispersed with and particle sizes ranging from 9 to 31 nm with spherical shapes which are cle
... Show MoreThe current study involves an experimental investigation of plasma main parameters of a DC discharge with a hollow cathode (HCD) geometry in air using apertures of different diameters from the hollow cathode (1, 1.5, 2, and 2.5 cm). A tiny Langmuir probe is used to investigate the plasma properties. The HCD was operated at constant power of 12.4 W and gas pressures ranging between 0.1 to 0.8 torr. It was observed that the operational conditions strongly affect the electron temperature and density, while the hollow cathode diameter has not much influence. The main important observation was that at relatively high air pressure (>0.4 torr) two electron temperatures were obtained, while at relatively low pressure (<0.4 torr)
... Show MoreLow-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro
... Show MoreNon-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co
Colorectal cancer (CRC) Patients showed different expression patterns of miRNAs which are involved in carcinogenesis in comparison to healthy controls individuals, miRNAs are involved in tumor progression and development of metastases. We investigate the expression profile of microRNA 320 and to quantify the expression level abundance among colorectal cancer patients in comparison to the healthy control group. The A total number of 60 plasma samples was collected from CRC patients along with 40 plasma samples from healthy controls and subjected to relative quantification using qPCR assay with a specified set of primers designed using s
... Show MoreThe aim of this research is to design and construct a
semiconductor laser range finder operating in the near infrared range
for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of wavelength
0.904 μm with a beam expander and the receiver; a silicon pin
detector biased to approve the fast response time with it's collecting
optics. The transmitters pulse width was 200ns at a threshold current
of 10 Ampere and maximum operating current of 38 Ampere. The
repetition rate was set at 660Hz and the maximum operating output
power was around 1 watt. The divergence of the beam was 0.268o
the efficiency of the laser was 0.03% at a duty cycle of 1.32x
The current study was conducted for studying the impact of cold plasma on the expression level of three genes that participate in the biosynthesis of the phenylpropanoid pathway in Ocimum basilicum. These studied genes were cinnamate 4-hydroxylase (c4h), 4-coumarate CoA ligase (4cl), and eugenol O-methyl transferase (eomt). Also, the cold plasma impact was studied on the essential oil components and their relation with the gene expression level. The results demonstrated that cold plasma seeds germination of the treated groups 2 (initially for 3 minutes and 3 minutes after 7 days) ,and group 3(initially for 5 minutes and 3 minutes after 7 days) were faster than the control group. Also, the height average of the mature plants of
... Show More