Preferred Language
Articles
/
ijp-1017
The Effect of Power on Inductively Coupled Plasma Parameters
...Show More Authors

In this work, we studied the effect of power variation ​​on inductively coupled plasma parameters using numerical simulation. Different values ​​were used for input power (750 W-1500 W), gas temperature 300K, gas pressure (0.02torr),         5 tourns of the copper coil and the plasma was produced at radio frequency (RF) 13.56 MHZ on the coil above the quartz chamber. For the previous purpose, a computer simulation in two dimensions axisymmetric, based on finite element method, was implemented for argon plasma. Based on the results we were able to obtain plasma with a higher density, which was represented by obtaining the plasma parameters (electron density, electric potential, total power, number density of argon ions, electron temperature, number density of excited argon atoms) where the high density in the generated plasma provides a greater degree in material processing, which increases the efficiency of the system. These results may aid in future research towards the development of more efficient optimization of plasma parameters which are (electron density, electric potential, total power, number density of argon ions, electron temperature, and number density of excited argon atoms).        

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 02 2022
Journal Name
Elementary Education Online
the power of the federal supreme court to stop the implementation of the law
...Show More Authors

the power of the federal supreme court to stop the implementation of the law

Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Experimental study for the properties of Fe3O4 dusty plasma using the air in vacuum chamber system
...Show More Authors

In this work, we carried out an experimental study of thedusty
plasma by taking the dust material Fe3O4 with radius of the any grain
0.1μm - 0.5μm. In experiment we use air in the vacuum chamber
system under different low pressure (0.1-1) Torr. The results
illustrated that the present of dust particles in the air plasma did not
effect on Paschen minimum which is 0.5 without dust and with Fe3O4
dusty grains.
The effect of Fe3O4 dust particles on plasma parameters can be
notice in direct current system in glow discharge region. The plasma
parameters which were studied in this work represent plasma
potential, floating potential,electron saturation current, temperatu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Comparing parameters and Reliability of two-parameters exponential
...Show More Authors

One of the most important problems in the statistical inference is estimating parameters and Reliability parameter and also interval estimation , and testing hypothesis . estimating two parameters of exponential distribution and also reliability parameter in a stress-strength model.

This parameter deals with estimating the scale parameter and the Location parameter µ , of two exponential distribution   ,using moments estimator and maximum likelihood estimator , also we estimate the parameter R=pr(x>y), where x,y are two- parameter independent exponential random variables .

Statistical properties of this distribution and its properti

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
Increasing the conversion efficiency of KTP crystal using the pump-power technique
...Show More Authors

In this study, the effect of pumping power on the conversion efficiency of nonlinear crystal (KTP) was investigated using laser pump-power technique. The results showed that the higher the pumping power values, the greater the conversion efficiency (η) and, as the crystal thickness increases within limitations, the energy conversion efficiency increases at delay time of (0.333 ns) and at room temperature. Efficiency of 80% at length of KTP crystal (L = 1.75 X 10-3 m) and Pin = 28MW, and also, compare the experimental results with numerical results by using MATLAB program. 

View Publication Preview PDF
Crossref
Publication Date
Thu Dec 27 2018
Journal Name
Revue Académique De La Recherche Juridique
Extent and limits of the judge's power to the contract (Comparative study)
...Show More Authors

The contractual imbalance is perceived today by the majority of the doctrine as being one of the pitfalls to the execution of the contracts. As a result, most legislations grant judges the power to intervene to restore it. Granting the judge the power to complete the contract raises the question of the extent to which the judge can obtain such power. Is it an absolute authority that is not limited? If so, is it a broad discretion in which the judge operates in his conscience, or is it a power of limited scope by specific legal texts and conventions? This is what we will try to answer in this research.

View Publication
Publication Date
Tue Jul 01 2014
Journal Name
Political Sciences Journal
For assuming the presidency of the political power in contemporary Islamic thought
...Show More Authors

مدة تولي رئاسة السلطة في الفكر السياسي الاسلامي المعاصر

View Publication Preview PDF
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic measurements of the electron temperature in low pressure microwave 2.45 GHz argon plasma
...Show More Authors

The main goal of this work is to obtain the plasma electron temperature Te by optical emission spectroscopy of low pressure microwave argon plasma, as a function of working pressure and microwave power. A plasma system was designed and constructed in our laboratory using a magnetron of domestic microwave oven with power 800W without any commercial part. The applied voltage on the magnetron electrical circuit is changed for the purpose of obtaining the variable values of the microwave power. The spectral detection is performed with a spectrometer of wavelength range (200−1000nm). The working pressure and magnetron applied voltage were 0.3-3.0mbar and 180-240V, respectively. Two methods had been applied to estimate the electron temperatu

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
The axial profile of plasma characteristics of cylindrical magnetron sputtering device
...Show More Authors

In the present work, a d.c. magnetron sputtering system was designed and fabricated. The chamber of this system was includes from two copper coaxial cylinders where the inner one used as a cathode (target) while the outer one used as the anode with Solenoid magnetic coil located on the outer cylinder (anode). The axial profile of magnetic field for various coil current (from 2A to 14 A) are shown. The plasma characteristics in the normal glow discharge region are diagnostics by the 2.2mm diameter Langmuir probe with different length along the cathode and located at different radial positions 1cm and 2cm from the cathode surface. The result of this work shows that, the electron energy distributions at different radial positions along the

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 01 2024
Journal Name
Advances In Science And Technology Research Journal
Power Predicting for Power Take-Off Shaft of a Disc Maize Silage Harvester Using Machine Learning
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Aug 30 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Plasma Treatment on Shear Bond Strength of High Impact Acrylic Resin Denture Base Lined with Two Types of Soft Lining Materials after Immersion in Distilled Water and Denture Cleanser
...Show More Authors

Background: In dentistry, dentist takes the advantages of soft lining materials due to the viscoelastic properties. The major problem is the adhesion of the soft liner with the denture base material. Materials and Methods: Heat cured of high impact acrylic resin specimens prepared with dimensions 75x13x13mm for shear bond strength test, soft lining material (Refit and Mollosil) with a 3-mm thickness and used to join each two acrylic blocks. Also four specimens with the same previous dimensions utilized for chemical and physical surface analysis. The specimens grouped as control (without plasma) and experiment (with oxygen plasma) treated high impact acrylic specimens. Results: Plasma treatment increased the shear bond strength for both Refi

... Show More
View Publication Preview PDF