In this work, we studied the effect of power variation on inductively coupled plasma parameters using numerical simulation. Different values were used for input power (750 W-1500 W), gas temperature 300K, gas pressure (0.02torr), 5 tourns of the copper coil and the plasma was produced at radio frequency (RF) 13.56 MHZ on the coil above the quartz chamber. For the previous purpose, a computer simulation in two dimensions axisymmetric, based on finite element method, was implemented for argon plasma. Based on the results we were able to obtain plasma with a higher density, which was represented by obtaining the plasma parameters (electron density, electric potential, total power, number density of argon ions, electron temperature, number density of excited argon atoms) where the high density in the generated plasma provides a greater degree in material processing, which increases the efficiency of the system. These results may aid in future research towards the development of more efficient optimization of plasma parameters which are (electron density, electric potential, total power, number density of argon ions, electron temperature, and number density of excited argon atoms).
Objectives: The study aims to investigate the efficiency of physiotherapy methods to improve the
degree of the clinical recovery of the peripheral facial palsy.
Methodology: This study is carried out at the Rehabilitation Center-Baghdad from November 2009 till
March 2010. This study includes (40) patient, their ages are from (13) to (55) years old; (24) male and
(16) female with unilateral facial palsy of undetermined cause. House-Brackmann facial recovery
scores have been used before and after the physiotherapy treatment.
Results: The results show that the physiotherapy sessions obtained the best effect of the electrical
stimulation, exercises and massage in the treatment of facial palsy. Highly respondents in femal
Background: The aims of this study were to evaluate the effect of implant site preparation in low-density bone using osseodensification method in terms of implant stability changes during the osseous healing period and peri-implant bone density using CBCT. Material and methods: This prospective observational clinical study included 24 patients who received 46 dental implants that were installed in low-density bone using the osseodensification method. CBCT was used to measure the bone density pre- and postoperatively and implant stability was measured using Periotest® immediately after implant insertion and then after 6 weeks and 12 weeks postoperatively. The data were analyzed using paired t-test and the probability value <0.05 was conside
... Show MoreAbstract
The current research aims to identify the effect of the idea filtering strategy on the achievement of second-intermediate school female students in science. The two researchers adopted the experimental method and the experimental design with partial control in the two groups (experimental group and control group). The two researchers applied the research experience to a sample of students of the second intermediate grade in the school Martyrs of (Jiser Al Aimma for Girls) affiliated with the Baghdad Education Directorate / Rusafa /1 for the academic year (2021/2022), which was chosen intentionally. The number of female students in the research sample was (70) students, with (35) students for the ex
... Show MoreAbstract
The aim of the research is to identify the effect of using the self-questioning strategy on the achievement of fourth-grade students in science and the development of their reflective thinking in physics in the city of Baghdad. The research sample was divided into two groups: an experimental group of (20) students and a control group of (20) students. The researchers developed two tools: a test of (40) multiple-choice questions. The second tool is a test to measure the reflective thinking skills of fourth-grade students. It consists of (25) multiple-choice questions distributed on skills as follow: reflection and observation, detection of inaccuracies, reaching conclusions, giving clear explanations, an
... Show MoreThis work aims to optimize surface roughness, wall angle deviation, and average wall thickness as output responses of ALuminium-1050 alloy cone formed by the single point incremental sheet metal forming process. The experiments are accomplished based on the use of a mixed level Taguchi experimental design with an L18 orthogonal array. Six levels of step depth, three levels of tool diameter, feed rate, and tool rotational speed have been considered as input process parameters. The analyses of variance (ANOVA) have been used to investigate the significance of parameters and the effect of their levels for minimum surface roughness, minimum wall angle deviation, and maximum average wall thickness. The results indicate that step depth and tool r
... Show MoreSubmerged arc welding (SAW) process is an essential metal joining processes in industry. The quality of weld is a very important working aspect for the manufacturing and construction industries, the challenges are made optimal process environment. Design of experimental using Taguchi method (L9 orthogonal array (OA)) considering three SAW parameter are (welding current, arc voltage and welding speed) and three levels (300-350-400 Amp. , 32-36-40 V and 26-28-30 cm/min). The study was done on SAW process parameters on the mechanical properties of steel type comply with (ASTM A516 grade 70). Signal to Noise ratio (S/N) was computed to calculate the optimal process parameters. Percentage contributions of each parameter are validated by using an
... Show More