Preferred Language
Articles
/
ijp-1006
X-Ray Emission Spectroscopy Analysis for Near-Asteroid Belt of Atmospheric of the Comets
...Show More Authors

         According to Chandra Survey Observatory Near-Asteroid Belt Comets, the solar wind's contact with the comet produces a variety of spectral characteristics. The study of X-ray spectra produced by charge exchange is presented here. The spectrum of a comet can reveal a lot about its composition. This study has concentrated on the elemental abundance in six different comets, including 17P/Holmes, C/1999T1, C/2013A1, 9p/Temple1, and 103p/Hartley2 (NEAT). Numerous aspects of the comet's dynamics allow it to behave in a unique manner as it gets closer to the Near-Asteroid Belt. These characteristics are being examined, and some studies are still ongoing. The computations allow us to observe, for instance, how the composition of a comet's upper atmosphere affects how much gas it produces. For several comet morphologies, both linear and nonlinear, bow shock, contact surface, and stagnation point are investigated in relation to gas production rate. Our results shed light on the complex interactions between cometary ions and the solar wind. An increase in gas production rate was shown to be significantly correlated with sharp drops in average molecular weight.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Performance Analysis of Four Conceptual Designs for the Air Based Photovoltaic / Thermal Collectors
...Show More Authors

The  thermal  and  electrical  performance  of  different  designs  of  air  based  hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Mar 28 2020
Journal Name
Iraqi Journal Of Science
A Study on n-Derivation in Prime Near – Rings
...Show More Authors

The main purpose of this paper is to show that zero symmetric prime near-rings, satisfying certain identities on n-derivations, are commutative rings.

View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Mon Jun 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Breast Tumor Diagnosis Using Diode Laser in Near Infrared Region
...Show More Authors

In the last years, new non-invasively laser methods were used to detect breast tumors for pre- and postmenopausal females. The methods based on using laser radiation are safer than the other daily used methods for breast tumor detection like X-ray mammography, CT-scanner, and nuclear medicine.  

      One of these new methods is called FDPM (Frequency Domain Photon Migration). It is based on the modulation of laser beam by variable frequency sinusoidal waves. The modulated laser radiations illuminate the breast tissue and received from opposite side.

      In this paper the amplitude and the phase shift of the received signal were calculated according to the orig

... Show More
View Publication Preview PDF
Publication Date
Sun May 30 2021
Journal Name
Iraqi Journal Of Science
SOME RESULTS ABOUT GENERALIZED SEMIDERIVATIONS IN 3-PRIME NEAR-RINGS
...Show More Authors

   The purpose of this paper is to extend some results concerning generalized derivations to generalized semiderivations of 3-prime near rings.

View Publication Preview PDF
Scopus Crossref
Publication Date
Mon May 01 2017
Journal Name
Journal Of Nuclear Medicine
A hand-held hybrid gamma-near-infrared fluorescence imaging camera
...Show More Authors

Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamm

... Show More
Publication Date
Sun Jan 09 2022
Journal Name
Iraqi Journal Of Science
Near IR Photoconductive Detector Based on f-MWCNTs/Polythiophen Nanocomposite
...Show More Authors

Carbon nanotubes are an ideal material for infrared applications due to their
excellent electronic and photo electronic properties, suitable band gap, mechanical
and chemical stabilities. Functionalised multi-wall carbon nanotubes (f-MWCNTs)
were incorporated into polythiophen (PTh) matrix by electro polymerization
method. f-MWCNTs/ PTh nanocomposit films were prepared with 5wt% and
10wt% loading ratios of f-MWCNTs in the polymer matrix. The films are deposited
on porous silicon nanosurfaces to fabricate photoconductive detectors work in the
near IR region. The detectors were illuminated by semiconductor laser diode with
peak wavelength of 808 nm radiation power of 300 mW. FTIR spectra assignments
verify that t

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Analysis of human development indicators in the context of distributive justice for Iraq for the period 2003-2013
...Show More Authors

Abstract                                                                             

The government spending in Iraq and witnessed the changes and developments, especially after 2003, which outweighed consumer spending at the expense of capital expenditure and increased support and diversity of trends towards improving pension conditions for member

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Apr 10 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Gamma Ray Attenuation Coefficients for Lead Oxide and Iron Oxide Reinforced In Silicate Glasses as Radiation Shielding Windows
...Show More Authors

     In this work, the mass attenuation coefficient, effective atomic number and half value layer parameters were calculated for silicate (SiO2) mixed with various levels of lead oxide and iron oxide as reinforced materials. SiO2 was used with different concentrations of PbO and Fe2O3 (25, 50 and 75 weight %). The glass system was prepared by the melt-quenching method. The attenuation parameters were calculated at photon energies varying from 1keV to 100MeV using the XCOM program (version 3.1). In addition, the mass attenuation coefficient and half value layer parameters for selected glass samples were experimentally determined at photon energies 0.662 and 1.28 MeV emitted from radioactive sources 137Cs and 22Na respe

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Computer Modeling In Engineering & Sciences
A Review and Bibliometric Analysis of the Current Studies for the 6G Networks
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Tue Oct 30 2018
Journal Name
Journal Of Engineering
Accuracy Assessment of Stonex X-300 Laser Scanner Cameras
...Show More Authors

Assessment the actual accuracy of laboratory devices prior to first use is very important to know the capabilities of such devices and employ them in multiple domains. As the manual of the device provides information and values in laboratory conditions for the accuracy of these devices, thus the actual evaluation process is necessary.

In this paper, the accuracy of laser scanner (stonex X-300) cameras were evaluated, so that those cameras attached to the device and lead supporting role in it. This is particularly because the device manual did not contain sufficient information about those cameras.

To know the accuracy when using these cameras in close range photogrammetry, laser scanning (stonex X-300) de

... Show More
View Publication Preview PDF
Crossref