Solid state blue laser source is a solid state laser include generation of IR laser light 1064 nm and companied with other wavelength 810 nm that invented from other active medium (Tm:ZBLAN) and non-linear crystal (CLBO) are used to generate fourth harmonic of the resultant wavelength 1874 nm that is blue laser light of 460nm. Several optical component have been designed by multilayer dielectric structure and anti reflection coating analysis. By using MATLAB soft ware, the simulation done and used the following non linear material (ZrO2, HfO2, MgO, SiO, Ta2O5 CaF2) and other linear material (ZnO, MgF2, GaAs, AlAs, BaF2, LiF, TiO2) as coating material. The result showed that as more quarter wave layers are added to the structure, the reflectance spectrum acquires more oscillatory features, and a narrow, flat-topped high-reflectance region grows around the design wavelength, GaAs and MgF2 represent good choice for the coating material of the front and exit mirror of the system especially produces very narrow wavelength band width and excellent value for R=100 % , LiF2 and BaF2 are good choice used to coat non linear crystal. For the polarized dichroic beam splitter, 450 represent good choice for the incident angle and BK7 as substrate material and HfO2 as high refractive index material and ZnO as low index material for coating.
Objective: This in vitro study is aimed to compare and evaluate the cyclic fatigue of four varying NiTi rotary instrumentation systems. Method: In this study, four types of rotary files were used in four groups (10 files for each group), namely, Group A: Wave One Gold; Group B: AF Blue R3; Group C: One Curve; Group D: F6 SkyTaper. These groups were evaluated by a cyclic fatigue apparatus to measure cyclic fatigue resistance within the artificial metallic simulating canal that has a 60 angle of curvature, the curvature radius was 5 mm, whereas the inner diameter of the canal was 1.5 mm. All the files were rotated in artificial canals until they fracture. The resistance to cyclic fatigue was determined by counting the number of cycles to frac
... Show MoreBackground: In recent years, the prevalence of obesity has climbed sharply. Still, only a few safe and effective medications are approved as weight-loss drugs. Objective: This study aims to assess the knowledge and practice of community pharmacists in Iraq regarding the use of Liraglutide and Semaglutide as weight-loss medications. Method: A cross-sectional survey was implemented using a validated questionnaire and a convenient sample of Iraqi community pharmacists from different governorates. The questionnaire was created after conducting a literature review of the most important articles about liraglutide and semaglutide. The questionnaire consists of three sections. The first part was used to collect demographic information. The
... Show MoreBackground: In recent years, the prevalence of obesity has climbed sharply. Still, only a few safe and effective medications are approved as weight-loss drugs. Objective: This study aims to assess the knowledge and practice of community pharmacists in Iraq regarding the use of Liraglutide and Semaglutide as weight-loss medications. Method: A cross-sectional survey was implemented using a validated questionnaire and a convenient sample of Iraqi community pharmacists from different governorates. The questionnaire was created after conducting a literature review of the most important articles about liraglutide and semaglutide. The questionnaire consists of three sections. The first part was used to collect demographic information. The second a
... Show MoreThe ejector refrigeration system is a desirable choice to reduce energy consumption. A Computational Fluid Dynamics CFD simulation using the ANSYS package was performed to investigate the flow inside the ejector and determine the performance of a small-scale steam ejector. The experimental results showed that at the nozzle throat diameter of 2.6 mm and the evaporator temperature of 10oC, increasing boiler temperature from 110oC to 140oC decreases the entrainment ratio by 66.25%. At the boiler temperature of 120oC, increasing the evaporator temperature from 7.5 to 15 oC increases the entrainment ratio by 65.57%. While at the boiler temperature of 120oC and
... Show MoreThe curriculum is considered one of the most important corners for the educational process, it participates in achieving the educational equilibrium between its elements.
The curriculum of (History of the Art) in the college of Art Education / dept. of plastic art education and ceramic as the other curriculums and due to the subject of history of the art develop the knowledge, taste and experiment for art studier also this subject has a direct relation with practical educational activities like colors and growth the knowledge of the student in field of contents and symbols and evidences of meaning in old , medium and contemporary arts, due to the fact that this curriculum has been applied since long time more than four years, and
... Show MoreA theoretical model is developed to determine time evolution of temperature at the surface of an opaque target placed in air for cases characterized by the formation of laser supported absorption waves (LSAW) plasmas. The model takes into account the power temporal variation throughout an incident laser pulse, (i.e. pulse shape, or simply: pulse profile).
Three proposed profiles are employed and results are compared with the square pulse approximation of a constant power.
In this work Polyynes was synthesized by pulse laser ablation of graphite target in ethanol solution. UV-Visible Spectrophotometer, Fourier Transform Infrared Spectroscopy (FTIR) and Transmission electron microscopy (TEM) were used to study the optical absorption, chemical bonding, particle size and the morphology. UV absorption peaks coincide with the electronic transitions corresponding to linear hydrogen – capped polyyne (Cn+1H2), the absorption peaks intensity increased when the polyynes were produced at different laser energies and the formation rats of polyynes increased with the increasing of laser pulse number. The FTIR absorption peak at 2368.4 cm-1, 1640.0 cm-1 and 1276.
... Show More