Preferred Language
Articles
/
ijl-92
One dimensional Finite Element Solution of Moving Boundaries in Far IR Laser Tissue Ablation
...Show More Authors

In this work, the finite element analysis of moving coordinates has been used to study the thermal behavior of the tissue subjected to both continuous wave and pulsed CO2 laser. The results are compared with previously published data, and a good agreement has been found, which verifies the implemented theory. Some conclusions are obtained; As pulse width decreases, or repetition rate increases, or fluence increases then the char depth is decreased which can be explained by an increase in induced energy or its rate, which increases the ablation rate, leading to a decrease in char depth. Thus: An increase in the fluence or decreasing pulse width or increasing repetition rate will increase ablation rate, which will increase the depth of cutting. The selection of a proper laser parameters may be helpful for doctors in obtaining optimum advantages in such treatment.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Oct 25 2022
Journal Name
Aip Conference Proceedings
Consequence of violet laser irradiation on the optical properties of mawsoniteCu6Fe2SnS8 [CFTS] thin films deposited via semi-computerized spray pyrolysis technique
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
Comparison effect of violet and red laser irradiation on the structural properties of mawsonite Cu6Fe2SnS8 [CFTS] thin films deposited via (SCSPT)
...Show More Authors

View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Sep 09 2022
Journal Name
Journal Of Ovonic Research
The effects of CuO doping on structural, electrical and optical properties of CdO thin films deposited by pulsed laser deposition technique
...Show More Authors

Thin films of (CdO)x (CuO)1-x (where x = 0.0, 0.2, 0.3, 0.4 and 0.5) were prepared by the pulsed laser deposition. The CuO addition caused an increase in diffraction peaks intensity at (111) and a decrease in diffraction peaks intensity at (200). As CuO content increases, the band gap increases to a maximum of 3.51 eV, maximum resistivity of 8.251x 104 Ω.cm with mobility of 199.5 cm2 / V.s, when x= 0.5. The results show that the conductivity is ntype when x value was changed in the range (0 to 0.4) but further addition of CuO converted the samples to p-type.

View Publication
Scopus (7)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Pump-Probe Technique to Study of the All-Optical Switching Properties of Copper Phthalocyanine Thin Film prepared via Pulsed laser deposition
...Show More Authors
Abstract<p>Z-scan has been utilized for studying the non-linear properties and optical limiting behaviors of the dye Copper Phthalocyanine thin films. The refractive index is negative, which indicates a self-defocusing behavior and non-linear absorption coefficient (<italic>β</italic>) of CuPc is a positive sign is a result of RSA. The optical switching behaviors of dye have been researched with the use of the method of the pump-probe with 9ns Q-Switched Nd: YAG laser at pump beam equal to 532 nm and a probe beam equal to 630nm Diode laser. The thin films of copper Phthalocyanine also reflect a significant limiting of the optical power of CW laser with an adequate threshold of the opt</p> ... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue May 05 2015
Journal Name
International Journal Of Research In Pharmacy And Chemistry
NEW APPROACH FOR DETERMINATION OF MEBEVERINE BY QUENCHED FLUORESCENCE OF ANALYTICALLY INTERESTED SPECIES USING CONTINUOUS FLOW INJECTION LASER DIODE FLUORIMETER ANALYSER
...Show More Authors

The proposed method is sensitive, simple , fast for the determination of mebeverine hydrochloride in pure form or in pharmaceutical dosage . Using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. Where it is based upon the fluorescence of fluorescein sodium salt and quenching effect of fluorescence by mebeverine in aqueous medium. The calibration graph was linear in the concentration range 0.05 to10 mMol.L-1 (r= 0.9629) with relative standard deviation (RSD%) for 1 mMol.L-1mebeverine solution was lower than 3% (n=6). Three pharmaceutical drugs were used as an application for the determination of mebeverine. A comparison was made between the newly developed method of analysis wit

... Show More
View Publication
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Comparison consequence of violet and red laser irradiation on the optical properties of cobalt dioxide (CoO2) thin films prepared via (SCSPT)
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Nov 20 2015
Journal Name
Iraqi Journal Of Science
New Approach for Determination of Oxonium Ion in Inorganic Acids by Quenched Fluorescence of Analytically Interested Species via the Liberated Bromine Using Continuous Flow Injection Laser Diode Fluorimeter Analyser
...Show More Authors

A new method is characterized by simplicity, accuracy and speed for determination of Oxonuim ion in ionisable inorganic acid such as hydrochloric (0.1 - 10) ,Sulphuric ( 0.1 - 6 ),nitric ( 0.1 - 10 ), perchloric ( 0.1 - 7 ), acetic (0.1 - 100 ) and phosphoric ( 0.1 - 30 ) ( mMol.L-1 )acids. By continuous flow injection analysis. The proposed method was based on generation of bromine from the Bro-3-Br-- H3O+. Bromine reacts with fluorescein to quenches the fluorescence . A sample volume no.1 (31μl) and no.2 (35μl) were used with flow rate of 0.95 mL.min-1 using H2O line no.1as carrier stream and 1.3 mL.min-1 using fluorescein sodium salt line no.2. Linear regression of the concentration ( mMol.L-1 ) Vs quenched fluorescence gives a correla

... Show More
View Publication
Publication Date
Sat Mar 31 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Effect of Process Variables, Adsorption Kinetics and Equilibrium Studies of Hexavalent Chromium Removal from Aqueous Solution by Date Seeds and its Activated Carbon by ZnCl2
...Show More Authors

The adsorption of hexavalent chromium by preparing activated carbon from date seeds with zinc chloride as chemical activator and granular date seeds was studied in a batch system. The characteristics of date seeds and prepared activated carbon (ZAC) were determined and found to have a surface area 500.01 m2/g and 1050.01  m2/g , respectively and  iodine number of 485.78 mg/g and 1012.91  mg/g, respectively. The effects of PH value (2-12), initial sorbate concentration(50-450mg/L), adsorbent weight (0.004-0.036g) and contact time (30-150 min) on the adsorption process were studied . For Cr(VI) adsorption on ZAC, at 120 min time contact, pH solution 2 and 0.02  adsorbent  weight  will ach

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
A three-stage blumlein-circuit to generate transversely excited atmospheric nitrogen laser by using three spark gaps
...Show More Authors

In this research constructed N2 laser system by use developed method of electric discharge. In this method used four step of electric discharge by using four capacitors, three spark gaps, high tension power supply varying in range from 12kV to 24 kV and three resistors, this method called three stage blumlein circuit. The breakdown time delay of these parallel spark gaps cement strong ultraviolet preionization in the laser channel, thus the result of these amendments the laser output is many doubled and is more increasing than that obtained using the one and two stage blumlein circuits. This system has been designed and operated to give pulse laser with wavelength at 337.1 nm. This laser system can operate without mirrors and optical res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 30 2023
Journal Name
Optics Continuum
Ultrafast lithium disilicate veneer debonding time assisted by a CO<sub>2</sub> laser with temperature control
...Show More Authors

We report on using a CO2 (10.6 µm) laser to debond the lithium disilicate veneers. Sixty-four sound human premolar teeth and 64 veneer specimens were used in the study. The zigzag movement via CO2 laser handpiece along with an air-cooled jet to prevent temperature elevation above the necrosis temperature limit (5.5 C°) was applied. The optimal deboning irradiation time was super-fast, at about 5 seconds at 3 Watt CO2 laser power. It is 20 times less than any previously published work for veneers debonding. The enamel beneath the debonded veneers has been assessed by atomic force microscopy (AFM) and shear stress technique as criteria for the easiness of debonding. The

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref