The present work provides theoretical investigation of laser photoacoustic one dimensional imaging to detect a blood vessel or tumor embedded within normal tissue. The key task in photoacoustic imaging is to have acoustic signal that help to determine the size and location of the target object inside normal tissue. The analytical simulation used a spherical wave model representing target object (blood vessel or tumor) inside normal tissue. A computer program in MATLAB environment has been written to realize this simulation. This model generates time resolved acoustic wave signal that include both expansion and contraction parts of the wave. The photoacoustic signal from the target object is simulated for a range of laser pulse duration 10ns-10μs emitted from Nd:YAG laser, depth of target object 0.3-3 cm, distance from the object to the detector 0.7-3 cm and the diameter of target object 0.1-0.6 cm. The diameter of the object computed by the simulation is always being 75% of its value. The amplitude of the signal is directly proportional with the laser pulse energy and inversely proportional with the depth of target object and the distance from the object to the detector. The PA signal is fully generated in Nano second laser pulse duration range as it is short enough to fulfill the stress confinement condition.
Ultrasound is a mechanical energy which can generate altering zones of compression and rarefaction along its path in the tissues. Ultrasound imaging can provide a real time screening for blood and multiple organs to aiding the diagnostic and treatment. However, ultrasound has the potential to deposit energy in the blood and tissues causing bio effects which is depending on ultrasound characteristics that including frequency and the amount of intensity. These bio effects include either a stable cavitation presented non thermal effects or inertial cavitation of harmful effect on the tissues. The non-thermal cavitation can add features in diagnostic imaging and treatment more than the inertial cavitation. Ultrasound Contrast agents are a micro
... Show MoreThree-dimensional (3D) reconstruction from images is a most beneficial method of object regeneration by using a photo-realistic way that can be used in many fields. For industrial fields, it can be used to visualize the cracks within alloys or walls. In medical fields, it has been used as 3D scanner to reconstruct some human organs such as internal nose for plastic surgery or to reconstruct ear canal for fabricating a hearing aid device, and others. These applications need high accuracy details and measurement that represent the main issue which should be taken in consideration, also the other issues are cost, movability, and ease of use which should be taken into consideration. This work has presented an approach for design and construc
... Show MoreIn this paper we reported the microfabrication of three-dimensional structures using two-photon polymerization (2PP) in a mixture of MEH-PPV and an acrylic resin. Femtosecond laser operating at 800nm was employed for the two-photon polymerization processes. As a first step in this project we obtained the better composition in order to fabricate microstructers of MEH-PPV in the resin via two-photon polymerzation. Acknowledgement:This research is support by Mazur Group, Harvrad Universirt.
Background: Conventional MR imaging is essential for diagnosis and evaluation of the posterior fossa tumors Objectives: To assess the value of diffusion weighted imaging and apparent diffusion coefficient in making distinction between different histological types of posterior fossa tumors.
Type of the study: Cross-sectional study.
Methods: Brain MRI and DWI assessed 19 patients (12 female and 7 male) with MRI diagnosis of posterior fossa tumors. absolute ADC values of contrast -enhancing solid tumor region and ADC ratio of solid tumor to ADC of normal -appearing deep White matter were compared with histological diagnosis postoperatively .The m
... Show MoreNumerical simulations are carried out to evaluate the coherence concept’s effect on the performance regarding the optical system, when observing and imaging the planet’s surface. In numerous optical approaches, the coherence qualities of light sources play an important role. This paper provides an overview about the mathematical formulation of temporal and spatial coherence and incoherence properties of light sources. The circular aperture was used to describe the optical system like a telescope. The simulation results show that diffraction-limited for incoherent imaging system certainly improves the image. Yet, the quality of the image is degraded by the light source's highly spatial and temporal coherence properties, resulting in a
... Show MoreObjectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamm
... Show MoreThe metric dimension and dominating set are the concept of graph theory that can be developed in terms of the concept and its application in graph operations. One of some concepts in graph theory that combine these two concepts is resolving dominating number. In this paper, the definition of resolving dominating number is presented again as the term dominant metric dimension. The aims of this paper are to find the dominant metric dimension of some special graphs and corona product graphs of the connected graphs and , for some special graphs . The dominant metric dimension of is denoted by and the dominant metric dimension of corona product graph G and H is denoted by .
Numerical simulations are carried out to assess the quality of the circular and square apodize apertures in observing extrasolar planets. The logarithmic scale of the normalized point spread function of these apertures showed sharp decline in the radial frequency components reaching to 10-36 and 10-34 respectively and demonstrating promising results. This decline is associated with an increase in the full width of the point spread function. A trade off must be done between this full width and the radial frequency components to overcome the problem of imaging extrasolar planets.