The purpose of this work was to study the effects of the Nd:YAG laser on exposed dentinal
tubules of human extracted teeth using a scanning electron microscope (SEM). Eighty 2.5mm-thick
slices were cut at the cementoenamel junction from 20 extracted human teeth with an electric saw. A
diamond bur was used to remove the cementum layer to expose the dentinal tubules. Each slice was
sectioned into four equal quadrants and the specimens were randomly divided into four groups (A to D ).
Groups B to D were lased for 2 mins using an Nd:YAG laser at 6 pulses per second at energy outputs of
80 , 100 and 120 mJ. Group A served as control. Under SEM observation, nonlased specimens showed
numerous exposed dentinal tubules. SEM observation revealed that application of Nd:YAG laser at
energy output of 80 mJ may cause melting of dentin and partial closure of exposed dentinal tubules
without dentin surface cracking. But when the energy output raised to 100 and 120 mJ more sealing of
dentinal tubules occurs. Heat generation occurred in all lased groups but the amount of temperature
increase was within the permissible limits(less than 5.5⁰C). The measured sealing depths were from 3-
5μm for groups B-D and the width of the created groove was 30μm in all lased groups. In conclusion
lasing with nanosecond Nd:YAG with a wavelength of 1064nm at 120mJ with 6Hz for 2 minutes (group
D) shows the efficient laser parameters for complete sealing of exposed dentinal tubules without
temperature increase to the damaging level of the pulp tissue.
Acne scars are one of the most common problems following acne vulgaris. Despite the extensive list of available treatment modalities, their effectiveness depends upon the nature of the scar. Ablative lasers had been used to treat acne scars; one of them is the fractional CO2 laser. The aim of this study is to evaluate the outcome of fractional CO2 laser in the treatment of acne scars. Methods: Since January 2010 to June 2013, using 10600 nm fractional CO2 laser beams, the acne scar of 400 patients, 188 males and 212 females, mean age of 34 years, have been treated and classified according to severity into four grades following Goodman and Baron classification. Each patient underwent 3-5 sessions once monthly. The mean laser exposure time
... Show MoreBackground: Gingival crevice fluid (GCF) is a mixture of substances derived from serum, leukocytes, and structural cells of periodontium and oral bacteria. These substances possess a great potential for serving as indicators of periodontal disease and healing after therapy the main purpose of this study was to find if there is a difference in albumin concentration between healthy and diseased periodontal tissues and to compare between diseased group according to pocket depth Materials and methods: total sample composed of 60 pockets found in 35 patients all of them had no history of any systemic disease, The samples were divided in to three main group that include two diseased groups divided according to the depth of the periodontal pocket
... Show MoreIn this work, the elemental constituents of smoker and nonsmoker
teeth samples of human were analyzed by Laser induced breakdown
spectroscopy method (LIBS). Many elements have been detected in
the healthy teeth samples, the important once are Ca, P, Mg, Fe, Pb
and Na. Many differences were found between (female and male)
teeth in Ca, P, Mg, Na and Pb contents. The concentrations of most
toxic elements were found significantly in the smoker group. The
maximum concentrations of toxic elements such as Pb, Cd and Co
were found in older male age above 60 year. Also, it was found that
the minimum concentrations of trace elements such as Ca, P and Na
exist in this age group. From these results it is clear that the
Dielectric barrier discharges (DBD) can be described as the presence of contact with the discharge of one or more insulating layers located between two cylindrical or flat electrodes connected to an AC/pulse dc power supply. In this work, the properties of the plasma generated by dielectric barrier discharge (DBD) system without and with a glass insulator were studied. The plasma was generated at a constant voltage of 4 kV and fixed distance between the electrodes of 5 mm, and with a variable flow rate of argon gas (0.5, 1, 1.5, 2 and 2.5) L/min. The emission spectra of the DBD plasmas at different flow rates of argon gas have been recorded. Boltzmann plot method was used to calculate the plasma electron temperature (Te), and Stark broadeni
... Show MoreThe importance of knowledge is represented in the use of various sources of information, the corresponding to the same level of importance is the use of modern means and technologies in the delivery and investment of these sources to the beneficiaries, among these means and technologies are the multimedia that deal with most of the human senses, but the most important of which is sight and hearing, if these are invested the means in the field of education will give many positive results, such as the speed of receiving information, its clarity, and its freedom from impurities and influences, as well as its stability in memory as it is based on nderstanding, not memorization. On this basis, the experience of supporting the education process
... Show MoreThis study aims to fabricate and assess the β-tricalcium phosphate (β-TCP) bioactive ceramic coat layer on bioinert ceramic zirconia implants through the direct laser melting technique by applying a long-pulsed Nd:YAG laser of 1064 nm. Surface morphologies, adherence, and structural change in the coatings were evaluated by optical microscopy, field emission scanning electron microscope, hardness, and x-ray diffractometer. The elastic modulus (EM) of the coating was also determined using the nanoindentation test. The quality of the coating was improved when the laser power was 90 W with a decrease in the scan speed to 4 mm s−1. The chemical composition of the coat was maintained after laser processing; also, the Energy Dispersive
... Show MoreBackground: The demand for better esthetic during orthodontic treatment has increased nowadays, so orthodontists starting using esthetic arch wires, brackets and ligatures.Tooth colored brackets were introduced in different types of materials. Sapphire ceramic brackets are one type of esthetic brackets and their color stability remains the main concern for the clinicians and patients at the same time. The present study design to evaluate the effect of three different staining materials (pepsi, black tea and cigarette smoke) on the stainability of sapphire ceramic brackets bonded with three types of light cure orthodontic adhesives which include: Resilience, Enlight and Transbond. Materials and Methods: The sample consisted of three hundre
... Show MoreIn this work, the finite element analysis of moving coordinates has been used to study the thermal behavior of the tissue subjected to both continuous wave and pulsed CO2 laser. The results are compared with previously published data, and a good agreement has been found, which verifies the implemented theory. Some conclusions are obtained; As pulse width decreases, or repetition rate increases, or fluence increases then the char depth is decreased which can be explained by an increase in induced energy or its rate, which increases the ablation rate, leading to a decrease in char depth. Thus: An increase in the fluence or decreasing pulse width or increasing repetition rate will increase ablation rate, which will increase the depth of cut
... Show MoreBackground: Ceramic veneers represent the treatment of choice in minimally invasive esthetic dentistry; one of the critical factors in their long term success is marginal adaptation. The aim of the present study is to evaluate the marginal gap of ceramic veneers by using two different fabrication techniques and two different designs of preparation. Material and methods: A typodont maxillary central incisor used in the preparation from which metal dies were fabricated, which were in turn used to make forty stone dies. The dies divided into four experimental groups, each group had ten samples: A1: prepared with butt-joint incisal reduction and restored with IPS e.max CAD, A2: prepared with overlapped incisal reduction and restored with IPS e.
... Show MoreThis study has been carried out to evaluate the expression level of beta 2 microglobulin gene on patients infected by hepatitis C virus before and after treatment with interferon. The study included 117 hepatitis C patients comprising as 63 pre-treated patients, the range of age was between 20-65 year with a mean age of 48.12 ± 16.1 and 54 post-treated patients with age range was between 23-63 year with the mean of 46.1 ± 18.1. Also it was found that more than half of patients were located within third and fourth decade i.e. 30-49 year, with a percentage of 52.4% and 55.6 % for pre-treatment and post-treatment patients respectively. Moreover , regarding both groups, males are more than females with the ratio of ( 3.2:1) among p
... Show More