Preferred Language
Articles
/
ijl-86
Human Skin WoundWelding Using 980 nm Diode Laser: an in Vitro Experimental Study
...Show More Authors

Laser assisted skin wound closure offers many distinct advantages over conventional closure
techniques. The objective of this in vitro experimental study, carried out at the Institute of Laser for
Postgraduate Studies/Baghdad University, was to determine the effectiveness of 980 nm diode laser in
welding of human skin wounds. Multiple 3-4 cm long full thickness incisions in a specimen of human
skin obtained from the discarded panniculus of an Abdominoplasty operation were tried to be laser
welded using a 4 mm spot diameter laser beam from a 980 nm diode laser at different laser parameters
and modes of action. The tensile strength at the weld site was analyzed experimentally. Although laser
assisted wound welding did actually happen at many laser parameter settings, it was not strong enough to
be clinically useful in living human beings. Despite the 980-nm diode laser system has proved to be an
effective way of wound welding but it the weld was of low tensile strength to withstand living patient
normal daily activity and movement. It can really shorten the operative time required to close a wound if
proper laser parameters were used among an endless effective combinations of parameters. Further future
studies are highly recommended on live human beings

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Heating and Melting Model Induced by Laser Beam in Solid Material
...Show More Authors

An analytical method and a two-dimensional finite element model for treating the problem of laser heating and melting has been applied to aluminum 2519T87and stainless steel 304. The time needed to melt and vaporize and the effects of laser power density on the melt depth for two metals are also obtained. In addition, the depth profile and time evolution of the temperature before melting and after melting are given, in which a discontinuity in the temperature gradient is obviously observed due to the latent heat of fusion and the increment in thermal conductivity in solid phase. The analytical results that induced by  laser irradiation is in good agreement with numerical results.

View Publication Preview PDF
Publication Date
Thu Jan 23 2020
Journal Name
Iraqi Journal Of Laser
Fractional CO2 Laser Treatment of Mild Periorbital Wrinkles in Iraqi Patients
...Show More Authors

Background and Objective: Public demand for procedures to rejuvenate photodamaged facial skin have stimulated the use of fractional CO2 laser as a precise and predictable treatment modality. The purpose of this study was to assess the effect of fractional CO2 laser system for reducing periorbital rhytids.

Materials and Methods: twenty seven subjects with mild periocular wrinkles, and photoaged skin of the face were prospectively treated two to three times (according to clinical response) in the periorbital area with a fractional CO2 laser device equipped with a scanning hand piece. Improvements in eyelid wrinkles was evaluated clinically and photographically. Subjects also scored satisfaction and

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 06 2021
Journal Name
Webology
The Role Of Digital Informatics In The Quality Of Scientific Research In In University Libraries: An Analytical Study Of Iraqi Libraries
...Show More Authors

View Publication
Publication Date
Thu Nov 22 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Finite Elements Analysis Study of Warming Effect on Deboned Force for Embedded NiTinol Wire into Linear Low Density Polyethylene
...Show More Authors

This study presents the debonding propagation in single NiTi wire shape memory alloy into linear low-density polyethylene matrix composite the study of using the pull-out test. The aim of this study is to investigate the pull-out tests to check the interfacial strength of the polymer composite in two cases, with activation NiTinol wire and without activation. In this study, shape memory alloy NiTinol wire 2 mm diameter and linear fully annealed straight shape were used. The study involved experimental and finite element analysis and eventually comparison between them. This pull-out test is considered a substantial test because its results have a relation with behavior of smart composite materials. The pull-out test was carried out by a u

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Engineering
Experimental Study of Electrical and Thermal Efficiencies of a Photovoltaic Thermal (PVT) Hybrid Solar Water Collector with and Without Glass Cover
...Show More Authors

Investigating the thermal and electrical gains and efficiencies influence the designed photovoltaic thermal hybrid collector (PVT) under different weather conditions. The designed system was manufactured by attaching a fabricated cooling system made of serpentine tubes to a single PV panel and connecting it to an automatic controlling system for measuring, monitoring, and simultaneously collecting the required data. A removable glass cover had been used to study the effects of glazed and unglazed PVT panel situations. The research was conducted in February (winter) and July (summer), and March for daily solar radiation effects on efficiencies. The results indicated that electrical and thermal gains increased by the incre

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Sat Dec 31 2011
Journal Name
Al-kindy College Medical Journal
Human chorionic gonadotropin and Testosterone in Normal and Preeclamptic Pregnancies in Relation to Fetal sex
...Show More Authors

Back ground: The gender related difference
may be the result of pregandiol excretion in the
latter half of pregnancy.
Aim: This study is to evaluate the effects of fetal
gender on serum human chorionic gonadotropin
[HCG] and testosterone in normotensive and
preeclamptic pregnancies
Methods: The study consisted of fifty women with
singleton pergnancy in their third trimester. Twenty
five pregnancies were uncomplicated Among those
there were thirteen male, and twelve female fetuses
Twenty five pregnancies were complicated by
preeclampsia. Among those thirteen were with male,
and twelve were with female fetuses. Human
chorionic gonadotropin and total testosterone were
measured in maternal periphe

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2011
Journal Name
Advanced Materials Research
Experimental Test of Magneto-Rheological Directional Control Valve
...Show More Authors

Directional control valve is the main part in hydraulic system which has complex construction, such as moving spool to control the direction of actuator for required speed. Utilizing MR fluid properties, direct interface can be realized between magnetic field and fluid power without the need for moving parts like spool in directional control valves. This paper dedicates the experimental test of four ways, three position MR directional control valve. The experimental methods were done by connecting the MR directional control valve with hydraulic actuators. The experiment was conducted to show the principle work of the valve functionally and performance test for valve was done. The valve works proportionally to control the direction a

... Show More
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Oct 25 2023
Journal Name
Journal Of Optics
Integrated gallium phosphide-waveguide polarization rotator based on rotating a horizontal slot by 45 degree for 700 nm wavelength
...Show More Authors

Polarization manipulation elements operating at visible wavelengths represent a critical component of quantum communication sub-systems, equivalent to their telecom wavelength counterparts. The method proposed involves rotating the optic axis of the polarized input light by an angle of 45 degree, thereby converting the fundamental transverse electric (TE0) mode to the fundamental transverse magnetic (TM0) mode. This paper outlines an integrated gallium phosphide-waveguide polarization rotator, which relies on the rotation of a horizontal slot by 45 degree at a wavelength of 700 nm. This will ultimately lead to the conception of a mode hybridization phenomenon in the waveguide. The simulation results demonstrate a polarization co

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Wed Oct 25 2023
Journal Name
Journal Of Optics
Integrated gallium phosphide-waveguide polarization rotator based on rotating a horizontal slot by 45 degree for 700 nm wavelength
...Show More Authors
Abstract<p>Polarization manipulation elements operating at visible wavelengths represent a critical component of quantum communication sub-systems, equivalent to their telecom wavelength counterparts. The method proposed involves rotating the optic axis of the polarized input light by an angle of 45 degree, thereby converting the fundamental transverse electric (TE<sub>0</sub>) mode to the fundamental transverse magnetic (TM<sub>0</sub>) mode. This paper outlines an integrated gallium phosphide-waveguide polarization rotator, which relies on the rotation of a horizontal slot by 45 degree at a wavelength of 700 nm. This will ultimately lead to the conception of a mode hybridization phenomeno</p> ... Show More
Scopus Clarivate Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Molecular Detection of High-Risk Human Papillomavirus Genotypes from Cervical Lesions in Baghdad
...Show More Authors

Objective Using two complementary techniques of virus detection human papillomavirus (HPV)[capture of hybrids (CH) and polymerase chain reaction (PCR)], relate the cytological study and/or cervical biopsy with high-risk HPV (HPV-HR) genotypes presence, as well as relating their viral load (VL). Methods About 272 women, who presented most cell alterations compatible with lesions cervical HPV, which has been detected in all high risk by the CH method and HPV genotype detection by PCR. Results In 22% of the patients it was not detected HPV DNA. Genotype 16 and/or 18 was prevalent and was found in 33% of the 212 women studied, meanwhile, mixed infections were found by several genotypes in 25%. In as for the histological lesions found, in 61 pat

... Show More
View Publication
Scopus (2)
Scopus Crossref