Urinary stones are one of the most common painful disorders of the urinary system. Four new technologies have transformed the treatment of urinary stones: Electrohydraulic lithotripsy, ultrasonic lithotripsy, extracorporeal shock wave lithotripsy, and laser lithotripsy.The purpose of this study is to determine whether pulsed holmium laser energy is an effective method for fragmenting urinary tract stones in vitro, and to determine whether stone composition affects the efficacy of holmium laser lithotripsy. Human urinary stones of known composition with different sizes, shapes and colors were used for this study. The weight and the size of each stone were measured. The surgical laser system which used in our study is Ho:YAG laser(2100nm) with four adjustable parameters (Pulsed mode, Rep rate, Power, Exposure time ). After each laser irradiation, the laser parameters (different energy setting, Rep rate) and the time of each stone fragmentation were recorded and also the stones fragments were weighed and sorted using a metal ruler. All stones studied were successfully fragmented with Ho:YAG laser. Although there were differences in stone fragmentation time and ablation based on composition and sizes of the stones, in addition to factors related to laser system itself like mode of operation (single or double pulse mode) and pulse energy and pulse repetition rate and the power. The results of holmium laser lithotripsy for urinary stones have been uniformly excellent. The holmium: YAG laser has demonstrated its efficacy as a method of choice for fragmentation of urinary tract stones. Advantages include ability to fragment stones of all composition.
Patients are very concerned about the lengthy nature of orthodontic treatment. It is necessary to find a non-invasive way to quicken physiologic tooth movement. This study's objective was to assess the effectiveness of low-intensity laser therapy in shortening the time and discomfort of orthodontic treatment. Experimental work: Using a split-mouth study to compare tooth movement with conventional treatment and laser-accelerated orthodontic tooth movement. A patient presenting with a class II division I malocclusion characterized by the misalignment of the upper and lower teeth as classified by Angle’s molar classification system was indicated to undergo fixed orthodontic appliance orthodontic treatment. The treatment plan involved bila
... Show MoreBackground: Diabetes mellitus is a well
known metabolic and vascular illness associated
with high incidence of bacterial urinary tract
infections especially in diabetic complications
including both micro and macro-vascular types.
Objective: To study the incidence of bacterial
urinary tract infections in type 2 diabetic
patients, the type of micro-organism responsible
in relation to age, sex of patients, duration of the
disease & related micro & macrovascular
diabetic complications.
Methods: A prospective study of the diabetic
patients including 40 males with mean age of
54(±9) years and 50 females, mean age of 51(±7)
years and duration of the and sex matched
controls (27 males and 33
The most common nosocomial fungal infection in hospitals is urinary tract candidiasis. Candida albicans is the most prevalent cause of nosocomial fungal urinary tract infections, however Candida species distribution is changing rapidly. At the same time, the rise in urinary tract candidiasis has resulted in the emergence of antifungal-resistant Candida species. This study aimed to diagnose Candida Spp. In women with UTI and reveal the nucleotides sequences of CA-INT-L Gene to look for mutation within the gene. This study included 100 women patients suffering from urinary tract infections and vaginal swabs samples from those individuals were taken to identify the presence of Candida. They were between the ages of 22 and 67. Candida i
... Show MoreA case-control study was designed to find out the association between rs2234671 polymorphism of cxcr1 and rUTI in a sample of Iraqi women by polymerase chain reaction- sequence-specific primer (PCR-SSP) method. The current findings revealed that the genotype GC (OR= 7.86, 95% CI = 2.82-21.87, P= 7.7 × 10-5) and the C allele (OR= 3.93, 95% CI = 1.97 - 7.83, P = 9.8×10-5) are significantly associated with rUTI. However, the genotype GG played as a protective factor (OR= 0.12, 95% CI = 10.05 - 0.34, P = 4.0 ×10-5). Depending on these findings, the genotype GC is significantly associated with rUTI.
Four hundred and fifty urine samples were collected from patients suffering from urinary tract infection from the General Azadi hospital in Kurkuk province ,during the period of october 2007 till march 2008 . Results of bacteriological culture revealed that (168) out of (450) studied samples (37.3%) gave positive culture using blood agar and macConkey agar ; different species of bacterial isolates were detected using morphological and biochemical tests ,from these isolates the highest percentage of the isolates were from Escherichia coli when it was (100) isolates out of (190) isolate (52.63%) . one hundred isolates were distributed between (77) from females and (23) from
... Show MoreIn this research , design and study a (beam expander) for the Nd – YAG laser with (1.06 ?m) Wavelength has been studied at 5X zoom with narrow diversion in the room temperature. by using (ZEMAX) to study the system. Evaluate its performance via (ZEMAX) outputs, as bright Spot Diagram via (RMS), Ray Fan Plot, Geometric Encircled Energy and the value of Focal shift. Then study the effect of field of view on the outputs in the room temperature.
Several types of laser are used in experimental works in order to study the effects of laser on blood vessel. They differ from each other by a lot of properties mainly in wavelength, energy of the laser and pulse duration. In this study argon laser (488 nm- 514 nm) and continuous Nd: YAG laSer (1064 nm), have been applied to 50 samples of sheep blgod tesselS. Histologically, tha results of the study were different According to the txpe of L`sar used; apgon larer had distrabtave effects on $he blood vessal while continuous Nd: YAG laser Appeaped to be the safesd one on the blmod vessel architecture. This study concluded that argoj laser has da-aging ef&ect on
... Show MoreThere are many causes for epistaxis but it is mainly idiopathic in type. In Management of epistaxis there are different modality either medical or cautery(chemical or galvanic) recently laser is used in management of epistaxis. The type of laser used in current study was 810 nm diode laser. The aim of the study is to evaluate its efficiency in control of active and non active idiopathic epistaxis; The design of the study is interventional therapeutic trial. The study was performed from December 2011 to December 2012 in Al Yarmouk teaching hospital at otorhinolaryngology department. In current study the diode laser is used in different power with same exposure time in all application; The power density is measured and choose the best one
... Show More