Preferred Language
Articles
/
ijl-74
Urinary Tract Stones Fragmentation using (2100 nm) Holmium: YAG Laser: (In vitro Analysis)
...Show More Authors

Urinary stones are one of the most common painful disorders of the urinary system. Four new technologies have transformed the treatment of urinary stones: Electrohydraulic lithotripsy, ultrasonic lithotripsy, extracorporeal shock wave lithotripsy, and laser lithotripsy.The purpose of this study is to determine whether pulsed holmium laser energy is an effective method for fragmenting urinary tract stones in vitro, and to determine whether stone composition affects the efficacy of holmium laser lithotripsy. Human urinary stones of known composition with different sizes, shapes and colors were used for this study. The weight and the size of each stone were measured. The surgical laser system which used in our study is Ho:YAG laser(2100nm) with four adjustable parameters (Pulsed mode, Rep rate, Power, Exposure time ). After each laser irradiation, the laser parameters (different energy setting, Rep rate) and the time of each stone fragmentation were recorded and also the stones fragments were weighed and sorted using a metal ruler. All stones studied were successfully fragmented with Ho:YAG laser. Although there were differences in stone fragmentation time and ablation based on composition and sizes of the stones, in addition to factors related to laser system itself like mode of operation (single or double pulse mode) and pulse energy and pulse repetition rate and the power. The results of holmium laser lithotripsy for urinary stones have been uniformly excellent. The holmium: YAG laser has demonstrated its efficacy as a method of choice for fragmentation of urinary tract stones. Advantages include ability to fragment stones of all composition.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Reconstruction of 3D Shape for an Object using Laser Scanning Triangulation
...Show More Authors

This paper presents a method of designing and constructing a system capable of acquiring
the third dimension and reconstructs a 3D shape for an object from multi images of that object using
the principle of active optical triangulation. The system consists of an illumination source, a photo
detector, a movement mechanism and a PC, which is working as a controlling unit for the hard ware
components and as an image processing unit for the object multi view raw images which must be
processed to extract the third dimension. The result showed that the optical triangulation method
provides a rapid mean for obtaining accurate and quantitative distance measurements. The final
result's analysis refers to the necessity of usin

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 05 2023
Journal Name
Optical And Quantum Electronics
Methylene blue degradation using ZnO:CuO:Al2O3 nanocomposite synthesized by liquid laser ablation
...Show More Authors

View Publication
Scopus (21)
Crossref (20)
Scopus Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Al-khwarizmi Engineering Journal
Study the Catalytic Activity of CeO2 Catalyst for the Oxidative Degradation of Orange G Dye in Aqueous Solution
...Show More Authors

The oxidative degradation of Orange G dye by nanosized CeO2 catalyst has been performed in this study. The catalyst was prepared by precipitation method. Various characterization techniques were carried out to study the physical and chemical properties of the synthesized catalyst. The XRD result confirms well the formation of CeO2 cubic phase.  The FTIR result showed the effect of calcination temperature for CeO2 was clearly observed due to reduction in band intensity compared to uncalcined Ce nitrate sample. Meanwhile, the diffused reflection spectra recorded reflection spectra at 414 nm with an energy gap of 3.2 ev. The decolorization of Orange G dye by oxidation process were carried out  unde

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Aug 30 2021
Journal Name
Al-kindy College Medical Journal
COVID-19 and Alimentary Tract: Current Evidence and Recent Recommendations
...Show More Authors

The pandemic of coronavirus disease 2019 (COVID-19), first reported in China, in December 2019 and since then the digestive tract involvement of  COVID-19 has been progressively described. In this review, I summed recent studies, which have addressed the pathophysiology of COVID-19-induced gastrointestinal symptoms, their prevalence, and bowel pathological and radiological findings of infected patients. The effects of gut microbiota on SARS-CoV-2 and the challenges of nutritional therapy of the infected patients are depicted.  Moreover, I provide a concise summary of the recommendations on the management of inflammatory bowel disease, colorectal cancer, and performing endoscopy in the COVID era. Finally, the COVID pancreatic re

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Iraqi Journal Of Laser
Treatment of Striae Grvidarum as a Type of Striae Distensae Using Long Pulsed Nd:YAG Laser (1064nm) and Fractional CO2 Laser (10600nm)
...Show More Authors

Striae distensae SD or stretch mark are frequent skin lesion that cause considerable aesthetic concern. The 1064nm long pulsed Nd:YAG Laser has been used to promote an increase in dermal collagen and is known to be a Laser that has a high affinity to vascular chromphores. Also by using fractional CO2 Laser 10600nm as an effective modality in treatment of striae distensae SD. It works to stimulate fibroblast and enhance Collagen formation, which is important for newly generated skin tissue.

Objectives: This study aims to verify the efficacy of long pulsed Nd: YAG Laser (1064nm) in the treatment of immature striae distensae (SD) and the efficacy of C02 fractional Laser (10600nm) in treatment o

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 23 2018
Journal Name
Journal Of Economics And Administrative Sciences
Processing of missing values in survey data using Principal Component Analysis and probabilistic Principal Component Analysis methods
...Show More Authors

The idea of ​​carrying out research on incomplete data came from the circumstances of our dear country and the horrors of war, which resulted in the missing of many important data and in all aspects of economic, natural, health, scientific life, etc.,. The reasons for the missing are different, including what is outside the will of the concerned or be the will of the concerned, which is planned for that because of the cost or risk or because of the lack of possibilities for inspection. The missing data in this study were processed using Principal Component  Analysis and self-organizing map methods using simulation. The variables of child health and variables affecting children's health were taken into account: breastfeed

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2014
Journal Name
Journal Of Thi – Qar Science
Enhanced of the Two photon Absorption in Nanostructure Wide Band gap Semiconductor CdS using femtosecond Laser
...Show More Authors

We observed strong nonlinear absorption in the CdS nanoparticles of dimension in the range 50-100 nm when irradiant with femtosecond pulsed laser at 800 nm and 120 GW/cm 2 irradiance intensity. The repetition rate and average power were 250 kHz and

View Publication
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Study of Laser Propagation Parameters in the Underdense Plasma Region Using a Two Dimensional Simulation Code
...Show More Authors

The propagation of laser beam in the underdense deuterium plasma has been studied via computer simulation using the fluid model. An appropriate computer code “HEATER” has been modified and is used for this purpose. The propagation is taken to be in a cylindrical symmetric medium. Different laser wavelengths (1 = 10.6 m, 2 = 1.06 m, and 3 = 0.53 m) with a Gaussian pulse type and 15 ns pulse widths have been considered. Absorption energy and laser flux have been calculated for different plasma and laser parameters. The absorbed laser energy showed maximum for  = 0.53 m. This high absorbitivity was inferred to the effect of the pondermotive force.

View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Tunable Optical filters Using Etched Polarization Maintaining Fiber Hybrid Sagnac Interferometer
...Show More Authors

: In modern optical communication system, noise rejection multiple access interference (MAI) must be rejected in dense access network (DAN). This paper will study the dual optical band pass and notch filters. They will be extracted with tunable FWHM using 10cm (PMF) with different cladding diameters formed with etching 125μm PMF after immersing it with 40% of hydrofluoric acid (HF). This fiber acts as assessing fiber to perform Sagnac interferometer with splicing regions that placed 12cm (SMF) for performing hybrid Sagnac interferometer that consists of Mach-Zehnder instead of Sagnac loop which is illuminated by using laser source with centroid wavelength of 1546.7nm and FWHM of 286 pm or 9 ns in the time domain. . Firs

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2016
Journal Name
Al-kindy College Medical Journal
Value of random urinary calcium to creatinine ratio in diagnosing hypercalciuria in children with nocturnal enuresis
...Show More Authors

Background:Nocturnal Enuresis is a common problem affecting 20% of five years old children and up to 2% of adolescent and young adult. Although it is a self limiting benign condition, it has social and psychological impact on the child and his family. Many pathophysiological theories had been suggested, but none is confirmed. Hypercalciuria has been suggested to be associated with higher incidence of nocturnal enuresis. Objectives:The aim of our study to test the value of Ca/Cr ratio, on random urine sample, in diagnosing hypercalciuria in enuretic children. Type of study: Cross sectional study.Methods:Forty four enuretic children were enrolled in this study and forty five children without nocturnal enuresis were taken as control group.

... Show More
View Publication Preview PDF