CO2 laser (10.6 μm) is the most often used laser in the oral surgery due to its high absorption by water of the oral tissues. Several benefits of the use of CO2 laser have been reported for oral surgical procedures. This study aims to evaluate the effect of CO2 laser on soft and hard oral tissues (in vitro study). This study was done on fresh tissues from sheep’s head. CO2Surgical Laser with different operation modes was used; 0.2 mm spot size using different laser parameters on the tongue, and bone making holes, incisions and cutting. The depths and widths of holes and incisions were measured using endodontic file under magnification. The speed of incisions was calculated and the required time for cutting was measured using sport clock. The depths of holes and incisions were increasing with increasing the power density and pulse duration from 90 μs to 1.7 ms in 100 μs increments and so in CW mode (for holes 2.5 mm at 15W, for incisions 6mm at 20W). Also the diameter of holes was increasing with power (1.2 mm at 15W) .The required time for cutting was decreasing as the power increased (14.14 sec. at 25W). The use of CO2 laser can be considered practical, effective and easy to carry out holes, incisions, and cuttings.
The present work investigated the effect of distance from target surface on the parameters of lead plasma excited by 1064nm Q-switched Nd:YAG laser. The excitation was conducted in air, at atmospheric pressure, with pulse length of 5 ns, and at different pulse laser energies. Electron temperature was calculated by Boltzmann plot method based on the PbI emission spectral lines (369.03 nm, 416.98 nm, 523.48, and 561.94 nm). The PbI lines were recorded at different distances from the target surface at laser pulse energies of 260 and 280 mJ. The emission intensity of plasma increased with increasing the lens-to-target distance. The results also detected an increase in electron temperature with increasing the di
... Show MoreBackground: Dental implant surface technologies have been evolving rapidly to enhance a more rapid bone formation on their surface and improve implant therapy.Implant threads should be designed to increase surface contact areathat induced better stability. In addition, implant surface coating with Flaxseed was used to enhance bone formation at the bone-implant interface. Materials and methods: Ninety-six commercially pure titanium (CpTi) screws were implanted in rabbits' tibiae and divided into three groups as dual-threaded group, flaxseed-coated group and control group. All groups were evaluated mechanically, histologically and radiographically after each healing periods (2, 4, 6 and 8) weeks and the resulting data were statistically analy
... Show MoreThe aim of this research is to calculate mass transfer coefficient, kd, during cathodic protection of low carbon steel in neutral seawater (3.5% W/V NaCl in distilled water with pH = 7). Two types of cathodic protection were used:
First: Sacrificial anode cathodic protection (SACP) were a pipeline of steel carrying seawater using zinc as a sacrificial anode and with variable temperatures ranged (0 – 45oC) and volumetric flow rate ranged (5 – 900 lit/hr). It was found that the kd increases with increasing temperature and volumetric flow rate of seawater, where kd ranged (0.24×10-6 – 41.6×10-6 m/s).
Second: Impressed current cathodic pr
... Show MoreGastritis can be defined as histological inflammation of the gastric mucosa. It can be classified according to the time course of the disease as acute or chronic, histological findings, anatomic location, and pathological mechanisms. The objective of this study was to evaluation of serum levels of the proinflammatory cytokines IL-8, IL-17 and IL-22 in Helicobacter pylori infection and their association with the degree of gastritis histopathology in a sample of Iraqi patients. The case-control prospective study consists of 60 patients who attended the Gastrointestinal Tract Center at Al-Kindy Teaching Hospital during the period from December 2019 to April 2020. In addition, the control group included 60 apparently healthy individuals. Bio
... Show MoreBackground: Aesthetic archwires are used to overcome the aesthetic problems of stainless steel wires but the color of the coating layer can be changed with time when exposed to oral environments. The aim of this study was to evaluate the degree of color change of different aesthetic archwires from different companies under different coloring solutions. Materials and Methods: One hundred fifty samples of coated archwires from three companies (Highland, G&H and Dany) were immersed in 5 solutions (artificial saliva, turmeric, tea, coffee and Miranda) to evaluate the degree of color changes after 7, 14 and 21 days using visible spectrophotometer. Data were collected and analyzed using one way ANOVA and post hoc Tukey’s tests. Resu
... Show MoreObjective(s): To assess the adequacy of mediation program on medical attendants practice toward care of kids with diabetic's ketoacidosis. Methodology: A quasi-experimental design that applied at teaching hospitals for pediatric in AL Ramadi city to establish the Effectiveness of Intervention Program on Nurses` Practices about Care of Children with Diabetic Ketoacidosis from 3th of March 2022 till 20 of March 2023. Non-probability (purposive) sample of (50), likewise was alienated into the study (experimental) group. The study group included (50) nurses non-randomly selected from AL-Ramadi Teaching Hospital.
A preliminary study has conducted in AL-Ramadi Teaching Hospital The whole number of nurse
... Show MoreBackground: With the increase in composite material use in posterior teeth, the concerns about the polymerization shrinkage has increased with the concerns about the formation of marginal gaps in the oral cavity environment. New generation of adhesives called universal adhesive have been introduced to the market in order to reduce the technique sensitive bonding procedures to give the advantage of using the bonding system in any etching protocol without compromising the bonding strength. The aim of the study was to study marginal adaptation of two universal adhesives (Single bondâ„¢ Universal and Prime and Bond elect) using 3 etching techniques under thermal cycling aging. Materials and Methods: Forty-eight sound maxillary first premola
... Show MoreThe international financial accounting and reporting standards IFRS/IAS represent the set of rules and foundations that the economic entity must follow in the measurement, presentation, and disclosure of the elements of the financial statements, the implementation of adopting the international financial reporting standards contributes to improving the qualitative characteristics of accounting information, so the current research aims to explain the role of adopting the International Accounting Standard (IAS) in improving the qualitative characteristics as well as analyzing the impact of the adoption of IAS.1 in improving the qualitative characteristics of accounting information within the financi
... Show MoreWe wanted to find out how selenium (Se) affects broiler chicken performance, meat physicochemical properties, and selenium deposition in the tissues of broilers. Each of the 96 experimental pens had 30 chickens and included a total of 2,880 one-day-old broilers (Cobb 500 strain). A factorial design of four-by-three (SY + SS) and eight replicates (SY + SS) was used for the 12 experimental treatments, with selenium levels ranging from 0.15 to 0.60 ppm and organic (SY) or inorganic (SS) sources of selenium and their relationship (SY + SS). There were no differences in performance (P > 0.05) across Se levels or sources. 106 g/day of ADFI, 63 g/day of ADG, and 1.6844 kg/kg of FCR were found to be the averaging values for these three parameters:
... Show MoreEffect of copper doping and thermal annealing on the structural and optical properties of Zn0.5Cd0.5S thin films prepared by chemical spray pyrolysis have been studied. Depositions were done at 250°C on glass substrate. The structural properties and surface morphology of deposited films were studied using X-ray diffraction (XRD) and photomicroscope (PHM) techniques. XRD studies reveal that all films are crystalline tetragonal structure. The film crystallinity are increased with 1% Cu-doping concentration and also increased for the films annealed at 300°C than the other studied cases. The lattice constant 'a' and 'c' varies with doping concentrations from 5.487Å to 5.427Å and 10.871Å to 10.757Å respectively. The grain size attained
... Show More