There are many causes for epistaxis but it is mainly idiopathic in type. In Management of epistaxis there are different modality either medical or cautery(chemical or galvanic) recently laser is used in management of epistaxis. The type of laser used in current study was 810 nm diode laser. The aim of the study is to evaluate its efficiency in control of active and non active idiopathic epistaxis; The design of the study is interventional therapeutic trial. The study was performed from December 2011 to December 2012 in Al Yarmouk teaching hospital at otorhinolaryngology department. In current study the diode laser is used in different power with same exposure time in all application; The power density is measured and choose the best one to stop both active and non active bleeding. The modality is compared with galvanic electrical cautery used in treatment of epistaxis. the comparison depends on the side effect and the complication of each modality.
Nowadays laser in medicine is a rapidly growing field in both researches and applications and many studies have been done in bacteriology against different types of lasers. The effect of the laser depends on many factors, one of the laser factors was the wavelength. The red wavelength band has been considered as a stimulated wavelength for prokaryotic and eukaryotic cells. In this study, three clinical species of Gram-negative bacteria (E. coli, Proteus mirabilis, and Pseudomonas aeruginosa) were exposed to 650 nm band of red region wavelength by a diode laser. The effect of that wavelength appeared on the growth curves for each species along 3 days after laser treatment. The energy density (E.D.) 2.8 J/cm2 gave a positive effect on grow
... Show MoreThis study aimed to compare the safety and efficacy of laser lithotripsy and pneumatic lithotripsy, the two most commonly used transurethral lithotripsy methods for treating bladder stones in children in Iraq. Between January 2013 and December 2016, 64 children with bladder stones were included in this prospective randomized study, after ethical committee approval and written consent from the children’s parents or caregivers were obtained. Patients were assigned randomly by computer software to two groups treated with either pneumatic cystolithotripsy or laser lithotripsy. A 9 Fr. semirigid ureteroscope was used to pass the lithotripter through and fragment the stone. A catheter of 8–12 Fr. was then introduced and kept in place
... Show MoreIt is found that hypersensitive teeth have a larger number and wider patent tubules than those of non-sensitive teeth. Objective: The aim of this study is to compare between the effects of diode laser at different power densities, with and without sodium fluoride on the sealing of exposed dentinal tubules and dentin permeability. Materials and methods: 118 teeth were used. Samples were divided into three major groups. The first consisted of 100 teeth used for permeability test. The second consisted of 16 teeth for measuring external surface temperature elevation while irradiation. The third, in turn, consisted of one pair of teeth observed under SEM for dentine surface morphology analysis. Results: For dentin permeability measurement, th
... Show MoreThe aim of the present study is to investigate and compare the efficacy of L-carnitine, multivitamins and their combination therapies on semen characteristics in idiopathic male infertility. Idiophathic infertile patients were randomly divided into three groups who had received three different treatment regimens for three months: group A (45 patients) has received 2 grams daily of L-carnitine alone; group B (55 patients) had received the combination of L-carnitine (2 grams daily) plus one tablet daily of multivitamins (Stresstabs®); and group C (29 patients) had received one tablet daily of multivitamins alone. The study was started on 1/11/2009 and completed on 31/3/2010 and performed at Rizgari Teaching Hospital in
... Show MoreDifferent methods can be used to remove tissue during gingivectomy and produce a good gingival margin, the most common is the conventional gingivectomy which is done by the use of scalpel, now a day’s Laser is widely spread and can be used to perform surgeries. Materials and methods: 50 patients divided into two equal groups, Group 1 gingivectomy was done by Diode Laser, Group 2 gingivectomy was done by scalpel, plaque and gingival index were measured at 1st, 2nd and 3rd visit, swab were taken and sent foe detecting bacterial growth and biopsy were taken for histopathological examination. Group 1 show no significant differences in plaque and gingival means between the visits, the bacteriological examination showed no growth of bact
... Show MoreBackground: different methods can be used to remove tissue during gingivectomy and produce a good gingival margin, the most common is the conventional gingivectomy which is done by the use of scalpel, now a day’s Laser is widely spread and can be used to perform surgeries. Materials and methods: 50 patients divided into two equal groups, Group 1 gingivectomy was done by Diode Laser, Group 2 gingivectomy was done by scalpel, plaque and gingival index were measured at 1st, 2nd and 3rd visit, swab were taken and sent foe detecting bacterial growth and biopsy were taken for histopathological examination. Group 1 show no significant differences in plaque and gingival means between the visits, the bacteriological examination showed no growth of
... Show MoreHemorrhoids are one of the most common surgical conditions. The hemorrhoid may cause symptoms that are: bleeding, pain, prolapse, itching, spoilage of feces, and psychologic discomfort. There are many methods for treatment of hemorrhoid like, medical therapy, rubber band ligation, electerocoagulation, stapled hemorrhoidpexy, photocoagulation, sclerothereapy, doppler guided artery ligation, Cryosurgery, and surgery. All methods for treatment of hemorrhoids have advantages, disadvantages, and limitations. Conventional haemorrhoidectomy was the traditional operation for the treatment of hemorrhoids. But recently other modalities of treatment had been used as an alternative operations including CO2 laser haemorrhoidectomy. This work aims to
... Show MoreThis research aims to design a high-speed laser diode driver and photodetector, the result is the
design of the high-speed laser diode driver with a short pulse of 10 ns at 30 KHz frequency and the
delivered maximum pulse voltage is 5.5 mV. Also, its optical output power of the laser diode driver is
about 2.529 mW for the centroied wavelength 1546.7 nm with FWHM of 286 pm and (1270-1610) nm.
The design of the circuit based on bipolar transistor where the input pulse signal is simply generated by
an arduino kit with 15 kHz frequency and then compensated to trigger to small signal amplifier which
was is simply NPN C3355 transistor and the output is a current driver to the laser diode. OptiSystem
software and Electronic
Back ground: primary nocturnal enuresis (PNE) is a socially distressing condition that can be troubling for children & their families. It affects 15-26% of five years olds. Several approaches are used to treat PNE including behavioral modification, alarms & drug therapy. Aim of the study: to determine the efficacy and safety of nasal desmopressin treatment in children with PNEPatients : fifty-four children with primary nocturnal enuresis with a mean age of ( 8.2) years ( range 6-15), underwent a 2 week observation period followed by entrance into a randomized controlled study, comparing desmopressin & placebo, lasting 4 weeks. The efficacy of the drug was measured in reduction of the number of wet nights per week. The enureti
... Show MoreThe aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in
... Show More