Preferred Language
Articles
/
ijl-64
The Efficacy of (810 Nm) Diode Laser in Treatment of Idiopathic Epistaxis
...Show More Authors

There are many causes for epistaxis but it is mainly idiopathic in type. In Management of epistaxis there are different modality either medical or cautery(chemical or galvanic) recently laser is used in management of epistaxis. The type of laser used in current study was 810 nm diode laser. The aim of the study is to evaluate its efficiency in control of active and non active idiopathic epistaxis; The design of the study is interventional therapeutic trial. The study was performed from December 2011 to December 2012 in Al Yarmouk teaching hospital at otorhinolaryngology department. In current study the diode laser is used in different power with same exposure time in all application; The power density is measured and choose the best one to stop both active and non active bleeding. The modality is compared with galvanic electrical cautery used in treatment of epistaxis. the comparison depends on the side effect and the complication of each modality.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Application of levofloxacin and doxycycline in treatment of vaginal chlamydial infection
...Show More Authors

Doxycycline and levofloxacin are heterocyclic organic compounds that are now popularly used to treat some bacterial infections. In this study which was conducted on patients from a private clinic, we compared the use of two commonly used antibiotics for the treatment of diagnosed cases with vaginal chlamydial infection: levofloxacin and doxycycline. Vaginal chlamydial infection is considered to be a very common sexually transmitted infection. It may have minimal symptoms which can lead to neglect by the patient until it leads to some important complications among which is the inability to become pregnant. This indicates early diagnosis and treatment of this infection. By comparing the results of treatment we concluded that there is no much

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun May 15 2022
Journal Name
Bionatura
Comparison between the presence and absence of mixing in the anaerobic biological treatment of liquid waste for the cheese industry
...Show More Authors

Many nations are seeing an increase in water pollution from dairy and cheese production due to the high organic and fat content in their waste products and the high temperature of their waste products, which elevates the water temperature and causes loss to ecosystem components. Reusing industrial wastewater that has been treated to guarantee no harm has been done to the environment is being hampered by a lack of water. This study compares the presence and absence of mixing in the anaerobic biological treatment of liquid waste for the cheese industry. To decrease heat exchange with the external environment, cube-shaped anaerobic reactors with dimensions of (30 x 30 x 30) cm and thick glass (10 mm) were utilized in this investigation

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Laser
Effects of Ho: YAG Laser (2100nm) in Prostate Tissue: An in vitro Study
...Show More Authors

Benign prostate hyperplasia (BPH), non-cancerous enlargement of prostate, is the most prevalent disease entity in elderly men. BPH affects 40% of men after the age of 60year worldwide. BPH causes problems for patients with significant lower urinary tract obstructive symptoms, if not responding to medical therapy, surgical intervention is instituted. One method of the treatment of symptomatic BPH is laser prostatectomy. The understanding of tissue effects by laser radiation is very important for the safe clinical application of laser. Objective: study the 2100 nm Ho: YAG laser gross tissue effects in the prostate at different laser dose settings in an vitro model prostate tissue samples harvested from same specimen of open surgery prostat

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 06 2016
Journal Name
Journal Of Water And Health
The effect of chlorine and combined chlorine/UV treatment on coliphages in drinking water disinfection
...Show More Authors

Chlorine disinfection is a globally used method to ensure the safety of drinking water. However, it has not always been successful against viruses and, therefore, it is important to find new methods to disinfect water. Seventeen different coliphages were isolated from the treated municipal wastewater. These coliphages and MS2 were treated with different dosages of chlorine in drinking water, and a combined chlorine/ultraviolet irradiation treatment for the chlorine-resistant coliphages. Chlorine disinfection with 0.3–0.5 mg/L total chlorine (free Cl-dosage 0.12–0.21 mg/L) for 10 min achieved 2.5–5.7 Log10-reductions for 11 sensitive coliphages. The six most resistant coliphages showed no reduction with these chlorine concentra

... Show More
View Publication
Scopus (33)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Mon Sep 04 2023
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Factors Influencing Adalimumab Treatment Response in Patients with Rheumatoid Arthritis: The Future of Clinical Expertise
...Show More Authors

Rheumatoid arthritis (RA) is characterized by persistent joint inflammation, which is a defining feature of this chronic inflammatory condition. Considerable advancements have been made in the field of disease-modifying anti-rheumatic medicines (DMARDs), which effectively mitigate inflammation and forestall further joint deterioration. Anti-tumor necrosis factor-alpha (TNF-α) drugs, which are a class of biological DMARDs (bDMARDs), have been efficaciously employed in the treatment of RA in recent times Adalimumab, a TNF inhibitor, has demonstrated significant efficacy in reducing disease symptoms and halting disease progression in patients with RA. However, its use is associated with major side effects and high costs. In addition,

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Water
The Effect of UV and Combined Chlorine/UV Treatment on Coliphages in Drinking Water Disinfection
...Show More Authors

View Publication
Scopus (40)
Crossref (31)
Scopus Clarivate Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Effect of Laser Surface Modification on the Corrosion Resistance of Dental Alloys in Artificial Saliva Containing Alcoholic Beverages
...Show More Authors

The objective of this study is to demonstrate the corrosion behavior of dental alloys Co-Cr-Mo, Ni-Cr-Mo and Ti-Al-V in artificial saliva at pH=4 and 37oC enriched with ethyl alcohol at 8% percentage. The linear and cyclic polarizations were investigated by electrochemical measurements. Laser surface modification was achieved for the three dental alloys to improve corrosion resistance. The results show that corrosion resistance of Co-Cr-Mo and Ni-Cr-Mo alloys only were increased after laser treatment due to the fact that laser radiation has caused a smoother surface, in addition to the decrement in corrosion current densities (icorr) for Co-Cr-Mo and Ni-Cr-Mo alloys and the reverse scan in cyclic polarization became in the wider range of

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 06 2015
Journal Name
Baghdad Science Journal
Efficacy of some local isolates of Beauveria bassiana(Bals.) and Metarhizium anisopliae (Met.) in control of mosquito larvae of Culex quinquefasciatus (Say)
...Show More Authors

The main aim of this study is to investigate the ability of four local entomopathogenic isolates Beauveria bassiana (Bals.) and Metarhizium anisopliae (Met.) to control the mosquito larvae in the lab. The results revealed that the isolate (MARD48) B .bassiana reduced the survival rate of the mosquito larvae to (80%) followed by the isolate M. anisopliae (MARD10) to (90%) in the first two days of treatment, and 60 and 66% respectively in the third day. The results also showed that the isolate B. bassiana (MARD48) killed 50% of the population (LC50) with the concentration 1×104 conidia/ml compared to 1×107 conidia/ml for the isolates B. bassiana (MARD14) and M. anisopliae (MARD10), and 1×108 conidia/ml for the isolate B .bassiana (MARD76).

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 01 2018
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Slow sand filtration as a tertiary treatment for the secondary effluent from sewage treatment plant
...Show More Authors

A field-pilot scale slow sand filter (SSF) was constructed at Al-Rustamiya Sewage Treatment Plant (STP) in Baghdad city to investigate the removal efficiency in terms of Biochemical Oxygen Demand (BOD5), Chemical oxygen demand (COD), Total Suspended Solids (TSS) and Chloride concentrations for achieving better secondary effluent quality from this treatment plant. The SSF was designed at a 0.2 m/h filtration rate with filter area 1 m2 and total filter depth of 2.3 m. A filter sand media 0.35 mm in size and 1 m depth was supported by 0.2 m layer of gravel of size 5 mm. The secondary effluent from Al-Rustamiya STP was used as the influent to the slow sand filter. The results showed that the removal of BOD5, COD, TSS, and Chloride were

... Show More
Publication Date
Sun Jun 01 2008
Journal Name
Baghdad Science Journal
Study the Effect of thickness on the Optical Properties Performance of active polymeric laser media
...Show More Authors

The paper include study the effect thickness of the polymeric sample which is manufactured by thermo press way. The sample was used as an active tunable R6G laser media. The remarks show that, when the thickness of the samples is increased, with the same concentration, the spectrum will shift towards the short wavelength, & the quantum fluorescence yield will increased. The best result we obtained for the quantum fluorescence yield is (0.68) at the sample, with thickness (0.304mm) in Ethanol solvent, while when we used the Pure Water as a solvent, we found that the best quantum fluorescence yield is (0.63) at (0.18mm) thickness of the sample.

View Publication Preview PDF
Crossref