Preferred Language
Articles
/
ijl-63
Bactericidal Effect of CO2 Laser on Bacteria Associated With Dental Implant Infection: An In Vitro Study
...Show More Authors

One of the most popular causes for implant infection is dental plaque bacteria. Previous studies have shown the bactericidal effect of CO2 laser irradiation on bacteria associated with soft tissue surrounding the implant materials. No published studies have examined the effect of irradiation by CO2 laser on Streptococcus oralis and Staphylococcus aureus.The aim of this study was to evaluate the bactericidal effect of CO2 laser on bacteria that are causing dental implant infections. This study was carried out on two isolates of bacterial species out of 25 samples, isolated from patients having soft tissue infections around the dental implant. These two pure isolates including Streptococcus oralis and Staphylococcus aureus were identified by microscopic examination, culture characteristics ,biochemical tests and API system. Bacterial suspension (10-6 CFU/ml) was irradiated with 10600 nm CO2 laser,CW mode emission using different power densities 500 -3000W/cm2 (500 W/cm2 increment)with different exposure times 10-60s (10 sec.increment for isolate of Streptococcus oralis) and 5-30s (5 sec. increment for isolate of Staphylococcus aureus).After the irradiation, 100μl of bacterial suspension was spread over agar plates and incubated at 37 ºC for 24-48 hrs. under aerobic and anaerobic conditions according to the nature growth of bacteria. Colony forming units (CFUs) were counted and compared with control group then the bactericidal effect of CO2 laser was assessed in relation to the colony forming units of control group.In this study the maximum bactericidal effect of CO2 laser on S.oralis was 100% at 2500W/cm2 with exposure times 50 and 60s, whereas the CO2 laser eliminated 100% of S.aureus at 3000W/cm2 at 25 and 30 s exposure time.The results indicate that irradiation by CO2 laser CW mode emission may be useful in reducing bacterial colony forming units at low (such as 1000 W/cm2) and high power density. Also the results of this study reveal that complete or nearly complete reduction in the bacterial counts may be achieved.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jun 13 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Nd-YAG laser-irradiation on fluoride uptake by tooth enamel surface (In vitro)
...Show More Authors

Background: The irradiation of teeth with a laser results in an interaction between the light and the biological constituents of the dental hard substance, which is converted directly into heat.This thermal effect is the cause of the structural and chemical enamel changes.The combined treatment of topical fluoride agent with laser may increase fluoride uptake, and reduce progression of caries-like lesions. The aim of this study was to measure the uptake of the acidulated phosphate fluoride and sodium fluoride to the buccal and lingual caries-like lesion enamel surfaces before and after irradiated by Nd-YAG laser in comparison with matching control group. Materials and methods: The sample consisted of 30 human healthy upper premolar teeth wh

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 01 2017
Journal Name
Journal Of Craniofacial Surgery
Lateral Ridge Splitting (Expansion) With Immediate Placement of Endosseous Dental Implant Using Piezoelectric Device
...Show More Authors

View Publication
Crossref (18)
Crossref
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Reliability of the multipeg™ transducer in measuring dental implant stability by using a resonance frequency analysis device (Osstell®): An observational clinical study
...Show More Authors

Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Antibacterial Effect of Mastic Gum on Aerobic Oral Bacteria
...Show More Authors

Objective: To evaluate the antibacterial effect of mastic gum against the most common aerobic oral bacteria and
emphasized on oral streptococci.
Methodology: In this study 10 persons (males and females of 18-60 years old) were randomly assigned to chew
mastic gum (1.5 gm for 45 minutes). Mouth washes were collected before and after gum chewing .The two mouth
washes were diluted (10-1 – 10-6) and cultivated aerobically for 24 hours at 37C0 on BHI agar for total bacterial
count and on MSF agar for counting the oral streptococci.
Results: The results showed that the total bacterial count for staphylococci, Neisseria and oral streptococci on BHI
agar and MSF agar for oral streptococci after mastic chewing were highly r

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 20 2021
Journal Name
Journal Of Craniofacial Surgery
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,

... Show More
View Publication
Scopus (15)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Sun Nov 19 2017
Journal Name
Iraqi Journal Of Laser
Sulfur Hexafluoride (SF6) Trace Gas Sensing using Modulated CO2 Laser Beam
...Show More Authors

Photonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and the characterization of a relative humidity sensor based on a polymer-coated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) transmission mode. The fabrication of the sensor involved splicing a short (1 cm) length of Photonic Crystal Fiber (PCF) between two single-mode fibers (SMF). It was then coated with a layer of agarose solution. Experimental results showed that a high humidity sensitivity of 29.37 pm/%RH was achieved within a measurement range of 27–95%RH. The sensor also showed good repeatability, small size, measurement accuracy and wide humidity range. The RH sensitivity o

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 13 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different staining materials on color stability of sapphire brackets bonded with different types of light cure orthodontic adhesives (An in vitro study)
...Show More Authors

Background: The demand for better esthetic during orthodontic treatment has increased nowadays, so orthodontists starting using esthetic arch wires, brackets and ligatures.Tooth colored brackets were introduced in different types of materials. Sapphire ceramic brackets are one type of esthetic brackets and their color stability remains the main concern for the clinicians and patients at the same time. The present study design to evaluate the effect of three different staining materials (pepsi, black tea and cigarette smoke) on the stainability of sapphire ceramic brackets bonded with three types of light cure orthodontic adhesives which include: Resilience, Enlight and Transbond. Materials and Methods: The sample consisted of three hundre

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 27 2012
Journal Name
Journal Of Huazhong University Of Science And Technology [medical Sciences]
An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures
...Show More Authors

View Publication
Crossref (5)
Crossref
Publication Date
Sun Dec 05 2010
Journal Name
Iraqi Journal Of Laser
Comparative Histological Study of Dentinopulpal Responses in Class I Cavity Treated by Er: YAG Laser and Conventional Cavity Preparations: An in Vivo Trial
...Show More Authors

The purpose of this study is to investigate the histopathological response of dentinopulpal
response of human teeth to the Er: YAG laser cavity preparation in comparison with the conventional
class I cavity preparation. Thirty five sound human upper and lower first premolar teeth which were
needed to be extracted for orthodontic purposes were used in the study. Regarding to the method of
cavity preparation, the teeth were grouped into three groups; Group1; Control group which consists of
seven sound teeth without cavity preparation, Group2; Conventional cavity preparation group and group
3; Er: YAG laser cavity preparation group. Each of Group2 and3 consists of fourteen teeth that is
subdivided into: A. 7teeth that e

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Laser Detection and Tracking System Using an Array of Photodiodes with Fuzzy Logic controller
...Show More Authors

In this work laser detection and tracking system (LDTS) is designed and implemented using a fuzzy logic controller (FLC). A 5 mW He-Ne laser system and an array of nine PN photodiodes are used in the detection system. The FLC is simulated using MATLAB package and the result is stored in a lock up table to use it in the real time operation of the system. The results give a good system response in the target detection and tracking in the real time operation.

View Publication Preview PDF