One of the most popular causes for implant infection is dental plaque bacteria. Previous studies have shown the bactericidal effect of CO2 laser irradiation on bacteria associated with soft tissue surrounding the implant materials. No published studies have examined the effect of irradiation by CO2 laser on Streptococcus oralis and Staphylococcus aureus.The aim of this study was to evaluate the bactericidal effect of CO2 laser on bacteria that are causing dental implant infections. This study was carried out on two isolates of bacterial species out of 25 samples, isolated from patients having soft tissue infections around the dental implant. These two pure isolates including Streptococcus oralis and Staphylococcus aureus were identified by microscopic examination, culture characteristics ,biochemical tests and API system. Bacterial suspension (10-6 CFU/ml) was irradiated with 10600 nm CO2 laser,CW mode emission using different power densities 500 -3000W/cm2 (500 W/cm2 increment)with different exposure times 10-60s (10 sec.increment for isolate of Streptococcus oralis) and 5-30s (5 sec. increment for isolate of Staphylococcus aureus).After the irradiation, 100μl of bacterial suspension was spread over agar plates and incubated at 37 ºC for 24-48 hrs. under aerobic and anaerobic conditions according to the nature growth of bacteria. Colony forming units (CFUs) were counted and compared with control group then the bactericidal effect of CO2 laser was assessed in relation to the colony forming units of control group.In this study the maximum bactericidal effect of CO2 laser on S.oralis was 100% at 2500W/cm2 with exposure times 50 and 60s, whereas the CO2 laser eliminated 100% of S.aureus at 3000W/cm2 at 25 and 30 s exposure time.The results indicate that irradiation by CO2 laser CW mode emission may be useful in reducing bacterial colony forming units at low (such as 1000 W/cm2) and high power density. Also the results of this study reveal that complete or nearly complete reduction in the bacterial counts may be achieved.
The thermodynamic constanting of “crude and partially purified” Paraxonase(PON) was evaluated in the sera of “healthy and ectopic” pregnant women in order to characterize the reaction of PON with diethyl para-nitro phenyl phosphate as substrate.This study was performed on (17) women with ectopic pregnancy (EP) whose age between (25-55) years and (25) normal pregnant women with a mean age of (25 -55) years as a control group . Samples were collected from the Medical City, AL-Yarmook and Fatema AL-Zahraa hospitals during the period from Sep.2011 to April 2012.The study included the evaluation of “paraxonase activity, specific activity and total protein” in the (crude and partially purified) sera of EP pa
... Show MoreBack ground: Microbial penetration inside the implant's internal hole creates a bacterial reservoir that is related with an area of inflamed connective tissue opposite the fixture-abutment junction and this can affect the health of the peri-implant tissue. Aims of the study: Evaluate the types aerobic and anaerobic bacterial count-percentage and difference between Aerobic and Anaerobic microflora in the implant screw hole three months after implant placement. Monitor the periodontal health status of all patients, throughout the study. Material and methods: Study methodology; Eight partially edentulous patients received 20 dental implants and these implants done with flapless surgical procedure. All patients examined clinically to determined
... Show MoreThe aim of this study was to compare the effect of conventional implant site preparation technique and a combination of conventional/piezosurgery preparation on implant stability measured at different time intervals, insertion torque, and preparation time. A randomized controlled study was designed, it included 26 patients who received 54 dental implants randomly assigned to 2 groups; in the control group, implants were installed after conventional preparation with drills whereas the study group received implants after mixed conventional/piezosurgery preparation. The outcome variables included: implant stability measured immediately after implant insertion, at 8 weeks and 16 weeks postoperatively, insertion torque and preparation time. All
... Show MoreThe Purpose of this research is analysis and discussion " The Effect of Insurace Company Capital Adequacy in it’s Profitafility: An Empirical Study compared the two insurance (national, Iraqi), for a period of one year (2005) and the year (2014), as it is framed theoretical side for two topics head adequacy money the insurance company, and the profitability of the insurance company, and I've been using the research methodology and analytical, in the analysis and measurement of the capital of the insurance company adequacy, and profitability of the company, as the capital adequacy ratio was measured by dividing the total capital available on the total capital rate risk, after measured and appreciated in two insurance research, while I u
... Show MoreThe study included the investigation of fungi which associated with heavy animal's leather (Cows and Buffalos) and light (Sheep’s and Goats )through different processing stages (raw hides ,dehairing ,pickling,chrome tanned and stainning or finished stages)there were 10 genera and 25 species in addition to sterile fungi associated with animal leathers which included Alternaria ,Aspergillus,Cladosporium,Fusarium, Mucor , Penicillium , Rhizopus , and Trichoderma .Aspergillus and Penicillium have observed in all leather samples and different processing stages, and that the first time isolate two genera Helminthosporium , Stemphylium form leather for staining stage.
This study was conducted to determine the effects of concentration of hydrochloric acids, temperature, and time on the hydrolysis of soya proteins (defatted soya flour) by determining the value of total protein nitrogen concentration, and amino nitrogen concentration of protein, peptides, and amino acids, and then calculated the hydrolysis rate of proteins.
The variables of the conditions of hydrolysis process was achieved in this study with the following range value of tests parameter:
- Concentration of HCl solution ranged between 1-7 N,
- Hydrolysis temperature ranged between 35-95 °C, and
- The time of hydroly
Nano TiO2 thin films on glass substrates were prepared at a constant temperature of (373 K) and base vacuum (10-3 mbar), by pulsed laser deposition (PLD) using Nd:YAG laser at 1064 nm wavelength. The effects of different laser energies between (700-1000)mJ on the properties of TiO2 films was investigated. TiO2 thin films were characterized by X-ray diffraction (XRD) measurements have shown that the polycrystalline TiO2 prepared at laser energy 1000 mJ. Preparation also includes optical transmittance and absorption measurements as well as measuring the uniformity of the surface of these films. Optimum parameters have been identified for the growth of high-quality TiO2 films
... Show MoreThe aim of the research is to clarify the measurement of the impact regarding financial value of human resources on investors' decisions by considering that the human element is one of the assets of the company. Therefore, a set of criteria must be available to determine the applicability of these standards in the human resource because it has an effective role in the success for the company. Is to measure the value of human resources in a financial format according to the first two methods depends on the value and the second depends on the cost.
In order to achieve the objectives of the study, a questionnaire was designed to survey the views of a number of employees of the General Company for Leather Industries in order to arriv
... Show MoreBackground: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2
... Show More