One of the most popular causes for implant infection is dental plaque bacteria. Previous studies have shown the bactericidal effect of CO2 laser irradiation on bacteria associated with soft tissue surrounding the implant materials. No published studies have examined the effect of irradiation by CO2 laser on Streptococcus oralis and Staphylococcus aureus.The aim of this study was to evaluate the bactericidal effect of CO2 laser on bacteria that are causing dental implant infections. This study was carried out on two isolates of bacterial species out of 25 samples, isolated from patients having soft tissue infections around the dental implant. These two pure isolates including Streptococcus oralis and Staphylococcus aureus were identified by microscopic examination, culture characteristics ,biochemical tests and API system. Bacterial suspension (10-6 CFU/ml) was irradiated with 10600 nm CO2 laser,CW mode emission using different power densities 500 -3000W/cm2 (500 W/cm2 increment)with different exposure times 10-60s (10 sec.increment for isolate of Streptococcus oralis) and 5-30s (5 sec. increment for isolate of Staphylococcus aureus).After the irradiation, 100μl of bacterial suspension was spread over agar plates and incubated at 37 ºC for 24-48 hrs. under aerobic and anaerobic conditions according to the nature growth of bacteria. Colony forming units (CFUs) were counted and compared with control group then the bactericidal effect of CO2 laser was assessed in relation to the colony forming units of control group.In this study the maximum bactericidal effect of CO2 laser on S.oralis was 100% at 2500W/cm2 with exposure times 50 and 60s, whereas the CO2 laser eliminated 100% of S.aureus at 3000W/cm2 at 25 and 30 s exposure time.The results indicate that irradiation by CO2 laser CW mode emission may be useful in reducing bacterial colony forming units at low (such as 1000 W/cm2) and high power density. Also the results of this study reveal that complete or nearly complete reduction in the bacterial counts may be achieved.
Polyacrylamide Solutions of different concentrations (0.2, 0.4, 0.6, 0.8, 1.0 %) of Ag nanoparticles and ZnO nanoparticles were prepared, the viscosities and surface tension were measured for all solutions, where measurements indicated an increase in these properties with increased concentration, where the relative viscosity of polyacrylamide/zinc nanoparticles increased from 1.275 to 2.243, and the relative viscosity of polyacrylamide/silver nanoparticles increased from 1.178 to 1.934. Viscosity is significant parameters during electrospinning process. While the surface tension of the polyacrylamide/zinc nanoparticles has changed from 0.0343 Nm-1 to .0.0.0 Nm-1 and changed from .0.000Nm-1 to.0.0.0 Nm-1. Also the constants KH and KK were
... Show MoreAPDBN Rashid, International Journal of Humanities and Social Sciences/ RIMAK, 2023
Objectives: study the relation between the effect of time (long time duration) with high concentration of iodine
and study its effect on the activity of the thyroid gland (hormonal and histological changes).
Methodology: An experimental study was done on (30) albino rats (8 weeks of age) to know the effect of high
concentration of iodine on the activity of the thyroid gland (hormonal and histological changes) related with
time. The study last for six months for the period of 1/2/2007 to 31/7/2007, the experiment was carried out in the
research lab. of pathology department, College of Medicine, University of Baghdad.
Results: The study shows changes in hormonal levels of thyroid hormones (T3 & T4) and also histologic
The adhesion strength between Polyethylene (PE) film and Aluminum surface by using the adhesive material (Cyanoacrylate) has been studied. Aluminum (Al) was used as a substrate, and polyethylene (PE) was used as a film adhered to the Al surface. Standard specimens were prepared to use in the peeling test in dry condition, other specimens were immersed in water for 12 days at room temperature. the results for the specimens in the dry condition had shown that high value in the peel force and the peel energy, the peel force was 0.38*103 N/m and the peel energy was 0.605*103 N/m, peeling the film from Al surface leaves a residual of the adhesive material on both adherend, the failure for this specimen were combination of adhesive and cohesive f
... Show MoreObjectives: study the relation between the effect of time (long time duration) with high concentration of iodine
and study its effect on the activity of the thyroid gland (homonal and histological changes).
Methodology: An experimental study was done on (30) albino rats (8 weeks of age) to know the effect of high
concentration of iodine on the activity of the thyroid gland aiormonal and histological changes) related with
time. The study last for six months for the period of I/2/2007 to 31/7/2007, the experiment was carried out in the
research lab. of pathology deparment, College of Medicine, University of Baghdad.
Results: The study shows changes in homonal levels of thyroid hormones (T3 & T4) and also histological<
The sintering behavior of Alumina was investigated by adding TiO2. The addition of TiO2 lowered the sintering temperature of the Alumina compared with those of pure Alumina. The result suggests that TiO2 acts as an activator for sintering of Alumina. Water absorption, apparent porosity and density were examined for both pure and TiO2 added to Alumina samples. The variations of sintering behavior were discussed in terms of shrinkage, porosity, water absorption and density. Thermal shock resistance was also examined. In term of this work, the way of improving the thermal shock resistance in oxide- based materials by adding reactive Titania powder to the Alumina samples. The laboratory results showed an improvement in thermal shock resistance
... Show MoreThe study of green colour in glass has a special importance on the glass quality, specially the effect of ferrous oxides content of the limestone. Results obtained that there was a reduction in green colour when different ferrous oxide contents in the limestone were added in glass production, limestone sources from two quarries, and the first contains 0.67% ferrous oxide and the second posses less ferrous oxide.
Reduction of green colour showed higher transmittance12% and it could be suggested that reduction of ferrous oxides content in the limestone is of special importance on the optical properties of glass.