Preferred Language
Articles
/
ijl-59
Nanosecond Nd: YAG Laser Surface Cleaning of Metals and Marbles
...Show More Authors

Laser cleaning of materials’ surfaces implies the removal of deposited pollutants without affecting the material. Nanosecond Nd:YAG pulsed laser, operating at 1064 nm and 532nm, was utilized. Different laser intensities and number of pulses were used on metallic and non-metallic surfaces under O2 and Ar environments to remove metal oxide and crust. Cleaning efficiency was studied by optical microscope. The results indicated the superiority of 1064 nm over the 532 nm wavelength without any detectable damage to materials’ surfaces. Marble cleaned in Oxygen gas environment was better than in Ar gas.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 11 2006
Journal Name
Iraqi Journal Of Laser
In vivo N2 Laser Effect on Lymphocyte Transformation Capacity and Phagocytosis Activity in Mice
...Show More Authors

The objective of this in vivo study is to investigate the effects of 337.1 nm pulsed N2 laser on cellular immune response represented by lymphocyte transformation capacity and phagocytosis activity in laboratory animals. The samples include 60 adult male BALB/c mice, were divided into control group and experimental groups. The experimental groups were divided into two main groups according to the time period after N2 laser irradiation. Each group was divided into 9 subgroups which exposed to N2 laser radiation at different values of pulse repetition rates and exposure times. The results of immunological tests demonstrated that the exposure to 180 J/cm2 of N2 laser radiation induce adverse effect to cellular immune response. The results o

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 11 2003
Journal Name
Iraqi Journal Of Laser
Microdrop Size Measurement in a Mixing Unit Using Laser Technique
...Show More Authors

One of the troublesome duties in chemical industrial units is determining the instantaneous drop size distribution, which is created between two immiscible liquids within such units. In this work a complete system for measuring instantaneous droplet size is constructed. It consists of laser detection system (1mW He-Ne laser), drop generation system (turbine mixer unit), and microphotography system. Two immiscible liquids, water and kerosene were mixed together with different low volume fractions (0.0025, 0.02) of kerosene (as a dispersed phase) in water (as a continuous phase). The experiments were carried out at different rotational speed (1180- 2090 r.p.m) of the turbine mixer. The Sauter mean diameter of the drops was determined by la

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Laser Peening on Aluminum Alloy 7049 Using Black Paint Surface Coating
...Show More Authors

Abstract

Black paint laser peening (bPLP) technique is currently applied for many engineering materials , especially for aluminum alloys due to high improvement in fatigue life and strength . Constant and variable   bending fatigue tests have been performed at RT and stress ratio R= -1 . The results of the present  work observed that the significance of the surface work hardening which generated high negative residual stresses in bPLP specimens .The fatigue life  improvement factor (FLIF)  for bPLP constant fatigue behavior was from 2.543 to 3.3 compared to untreated  fatigue and the increase in fatigue strength at 107 cycle was 21% . The bPLP cumulative fatigue life behav

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 29 2018
Journal Name
Al-khwarizmi Engineering Journal
Surface Roughness Prediction for Steel 304 In Edm Using Response Graph Modeling
...Show More Authors

Electrical Discharge Machining (EDM) is a non-traditional cutting technique for metals removing which is relied upon the basic fact that negligible tool force is produced during the machining process. Also, electrical discharge machining is used in manufacturing very hard materials that are electrically conductive. Regarding the electrical discharge machining procedure, the most significant factor of the cutting parameter is the surface roughness (Ra). Conventional try and error method is time consuming as well as high cost. The purpose of the present research is to develop a mathematical model using response graph modeling (RGM). The impact of various parameters such as (current, pulsation on time and pulsation off time) are studied on

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser
...Show More Authors

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser
...Show More Authors

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Cross-focusing Effect of Two Intense Laser Beams on Electron Plasma Wave Excitation
...Show More Authors

This paper presents the effect of relativistic and ponderomotive nonlinearity on cross-focusing of two intense laser beams in a collisionless and unmagnetized plasma. It should be noted here that while considering the self-focusing due to relativistic electron mass variation, the electron ponderomotive density depression in the channel may also be important. Therefore/these two nonlinearties may simultaneously affect the self-focusing process. These nonlinearities depend not only on the intensity of one laser but also on the second laser. Therefore, one laser beam affects the dynamics of the second beam and hence the process of cross-focusing takes place. The electric field amplitude of the excited electron plasma wave (EPW) has been cal

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 15 2023
Journal Name
Bionatura
Surface assessment of CNC laser treated commercially pure Titanium and Ti 13 Zr 13 Nb alloy
...Show More Authors

This study aimed to evaluate the surface changes of commercial pure Titanium disks (CP Ti) and the Ti 13Nb 13 Zr (Alloy) with a zigzag pattern of laser surface treatment. In vitro, experimental study of CNC Laser treatment on the CP Ti and Alloy disks. Texturing the surfaces of CP Ti and Alloy disks via CNC laser, the sample disks were analyzed using surface roughness, wettability and FESEM. The FESEM revealed a proper increase in the surface texturing and roughness on macro and micro measures without crack formation or dramatic change of the core substance of the CP Ti and Alloy disks. The CNC laser is an effective and suitable method for surface texturing CP Ti and Alloy for dental implantology. Keywords: Commercial pure Titanium;

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Fri Jan 07 2022
Journal Name
Iraqi Journal Of Laser
Influence of Fractional CO2 Laser Irradiation on Temperature Elevation and Bonding Strength of Resin Cement to the Zirconia Ceramic
...Show More Authors

Abstract: Objectives: To investigate the effect of temperature elevation on the bonding strength of resin cement to the zirconia ceramic using fractional CO2 laser. Background: Fractional CO2 laser is an effective surface treatment of zirconia ceramic, as it increases the bonding strength of zirconia to resin cement. Methods: Thirty sintered zirconia discs (10 mm diameter, 2 mm thickness) were prepared and divided to three groups (N=10) and five diffident pulse durations were used in each group (0.1, 0.5, 1, 5 and 10 ms). Group A was treated with 10 W power setting, group B with 20 W and group C with 30 W. During laser irradiation, temperature elevation measurement was recorded for each specimen. Luting cement was bonded to the treated z

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
The Combined Effect of Q-Switched Nd:YAG Laser (532 Nm) and Safranin O on the Growth of Pseudomonas Aeruginosaand its Susceptibilityto Antibiotics and Pyocyanin Production
...Show More Authors

Twenty five samples out of sixty wound swabs taken from burn patients were identified as P. aeruginosabacteria by conventional methods. Antibiotics susceptibility tests were performed against thirteen antibiotics. P. aeruginosa samples were treated with 0.5 mg/ml of Safranin O solution then irradiated with 532nm Q-switched Nd:YAG laser at four energy densities (0.324, 0.704, 1.380, and 1.831 J/cm2) for different times of 5, 8 and 11 minutes with 5Hz repetition rate. The viability, susceptibility to antibiotic and production of pyocyanin were determined before and after irradiation. The results showed that the number of CFU/ml of P. aeruginosa decreased with increasing the dose of irradiation. Complete killing of cells was observed at 1.8

... Show More
View Publication Preview PDF