Preferred Language
Articles
/
ijl-56
Tissue Welding Using (800±10nm) Diode and (1064nm) Nd: YAG Lasers
...Show More Authors

Joining tissue is a growing problem in surgery with the advancement of the technology and more precise and difficult surgeries are done. Tissue welding using laser is a promising technique that might help in more advancement of the surgical practice. Objectives: To study the ability of laser in joining tissues and the optimum parameters for yielding good welding of tissues. Methods: An in-vitro study, done at the Institute of Laser, Baghdad University during the period from October 2008 to February 2009. Diode and Nd-YAG lasers were applied, using different sessions, on sheep small intestine with or without solder to obtain welding of a 2-mm length full thickness incision. Different powers and energies were used to get maximum effect. Results: Welding of sheep intestine had been achieved by Nd-YAG laser 1064 nm at 400 and 500 mJ and PRR 4Hz, using human albumin 20% as a solder. Welding failed using the diode laser 4W for 10 min with albumin and indocyanine green. Conclusion: Laser may be useful tool in certain condition for joining tissue and wound closure. This is important because in certain circumstances no other technique is feasible for wound closure.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Trajectory Tracking Control for a Wheeled Mobile Robot Using Fractional Order PIaDb Controller
...Show More Authors

Nowadays, Wheeled Mobile Robots (WMRs) have found many applications as industry, transportation, inspection, and other fields. Therefore, the trajectory tracking control of the nonholonomic wheeled mobile robots have an important problem. This work focus on the application of model-based on Fractional Order  PIaDb (FOPID) controller for trajectory tracking problem. The control algorithm based on the errors in postures of mobile robot which feed to FOPID controller to generate correction signals that transport to  torque for each driven wheel, and by means of dynamics model of mobile robot these torques used to compute the linear and angular speed to reach the desired pose. In this work a dynamics model of

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Developing a Prosthesis Design using A Gearbox to Replicate the Human Hand Mechanism
...Show More Authors

Prosthetic is an artificial tool that replaces a member of the human frame that is  absent because of ailment, damage, or distortion. The current research activities in Iraq draw interest to the upper limb discipline because of the growth in the number  of amputees. Thus, it becomes necessary to increase researches in this subject to help in reducing the struggling patients.  This paper describes the design and development of a prosthesis for people able and wear them from persons who have amputation in the hands. This design is composed of a hand with five fingers moving by means of a gearbox ism mechanism. The design of this artificial hand has 5 degrees of freedom. This artificial hand works based on the principle of &n

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
A Digital-Based Optimal AVR Design of Synchronous Generator Exciter Using LQR Technique
...Show More Authors

In this paper a new structure for the AVR of the power system exciter is proposed and designed using digital-based LQR. With two weighting matrices R and Q,  this method produces an optimal regulator that is used to generate the feedback control law. These matrices are called state and control weighting matrices and are used to balance between the relative importance of the input and the states in the cost function that is being optimized. A sample power system composed of single machine connected to an infinite- bus bar (SMIB) with both a conventional and a proposed Digital AVR (DAVR) is simulated. Evaluation results show that the DAVR damps well the oscillations of the terminal voltage and presents a faster respo

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Aes-atema International Conference Series - Advances And Trends In Engineering Materials And Their Applications
Effect of new tool geometry on weld strength of AA2024 aluminum alloy plates welded by friction stir spot welding process
...Show More Authors

A new tool geometry was used to achieve friction stir spot welding (FSSW) in which the shoulder was designed separately from the rotating pin, and in order to examine weldment strength through the modified tool, a lap joints of AA2024 aluminum alloy plate 1 mm thick were welded successfully by using 6 mm pin diameter and varying process parameters (rotational speeds, tool nose geometry, and depth of tool penetration in the lower welded plate). Experimental tests indicate that the maximum average tensile shear load was 3100 N at the best selected condition. Microstructure examination and micro hardness test along the spot zones were investigated as well as measuring pin penetration load. Visual inspection of the welded spot surface shows a g

... Show More
Scopus
Publication Date
Sat Oct 28 2023
Journal Name
Baghdad Science Journal
Qualitative and Quantitative Determination of Dapagliflozin Propanediol Monohydrate and Its Related Substances and Degradation Products Using LC-MS and Preparative Chromatography Methods
...Show More Authors

Dapagliflozin is a novel sodium-glucose cotransporter type 2 inhibitor. This work aims to develop a new
validated sensitive RP-HPLC coupled with a mass detector method for the determination of dapagliflozin, its
alpha isomer, and starting material in the presence of dapagliflozin major degradation products and an internal
standard (empagliflozin). The separation was achieved on BDS Hypersil column (length of 250mm, internal
diameter of 4.6 mm and 5-μm particle size) at a temperature of 35℃. Water and acetonitrile were used as
mobile phase A and B by gradient mode at a flow rate of 1 mL/min. A wavelength of 224nm was selected to
perform detection using a photo diode array detector. The method met the

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Tue Jun 14 2005
Journal Name
Iraqi Journal Of Laser
Design and Operation of Mini-TEA CO2 Laser and Investigation of Preionization Effect
...Show More Authors

A Mini-TEA CO2 laser system was designed and operated to obtain a pulse at 10.6 μm. Output energy of 30 mJ, with preionization pins, and pulse duration of 100ns were obtained. While an output energy of 6mJ and pulse duration of 100 ns in absence of pre-ionization were obtained. The system was operated with Ernest profile main-discharge electrodes. Dependencies of supply voltage and output laser energy on the pressure inside laser cavity were investigated as well as dependencies of supply voltage and output energy on the main capacitor(8CO2 : 8N2 : 82He :2CO). Efficiency of was calculated to be 4.4%.

View Publication Preview PDF
Publication Date
Thu Apr 14 2022
Journal Name
Nat. Volatiles & Essent. Oils,
Estimate The Amount of Amino and Fatty Acids in The Liver Tissue of Uromastyx Aegyptius Microlepis During the Periods of Hibernation (December) And Activity (May)
...Show More Authors

Amino and fatty acids in the liver tissue of Uromastyx aegyptius microlepis during the periods of hibernation (December) and activity (May) were estimate by a high performance liquid chromatography, liver of a lizard during the activity and hibernation seasons, contained 18 amino acids, which include, 10 essential amino acids and 8 non-essential amino acids, and the liver in the male lizard contained five fatty acids during each season, the concentration rates of all the amino acids during the activity season were higher than their counterparts during the hibernation season, the total concentrations of essential and non-essential amino acids during the activity season were 19434.8 µg/ml, which was greater than the total concentrations leve

... Show More
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
The Effect of Dual Diode Laser: (810,980) nm in Acceleration of Orthodontic Tooth Movement A Case Report
...Show More Authors

Patients are very concerned about the lengthy nature of orthodontic treatment. It is necessary to find a non-invasive way to quicken physiologic tooth movement. This study's objective was to assess the effectiveness of low-intensity laser therapy in shortening the time and discomfort of orthodontic treatment. Experimental work: Using a split-mouth study to compare tooth movement with conventional treatment and laser-accelerated orthodontic tooth movement. A patient presenting with a class II division I malocclusion characterized by the misalignment of the upper and lower teeth as classified by Angle’s molar classification system was indicated to undergo fixed orthodontic appliance orthodontic treatment. The treatment plan involved bila

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 17 2018
Journal Name
Iraqi Journal Of Laser
Thermal Effects of 940 nm Diode Laser on Dental Socket Blood after Teeth Extraction for Diabetic Patients
...Show More Authors

Abstract: Background: High percentage of diabetes patients complain from post extraction hemorrhage. Many types of hemostatic materials are used to stop bleeding after teeth extraction: diode lasers are good hemostatic agents owing to their highly absorption by hemoglobin therefore they are used in soft tissue procedures with relatively no effects on dental hard tissues due to their poorly absorption by water and hydroxyapatite. Objectives: The aim of this study is to evaluate the efficiency of diode laser to assist the clot formation after tooth extraction for type II diabetes patients with minimum temperature elevation to prevent periodontal destruction. Materials and methods: From 12 type II diabetes patients (7 males and 5 females wi

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Corrosion Inhibition of Medium Carbon Steel in the Acidic Medium Using Alcoholic and Aqueous Extract of Kujarat Tea Plant
...Show More Authors

This study deals with the corrosion inhibition of metal corrosion process of medium carbon steel using 1M HCl for kinetic studies and rate reaction determination. The weight loss method is applied to pieces of Medium carbon steel divided to Cubans with dimensions (0.4*2*2.4) cm , and use Tafel Extrapolation Method, the samples were polished using carbide silicon paper with dimensions of (180,200,400,600,800,1000). The samples were immersed in the alcoholic medium ethanol at a temperature 293K for 3hr. Natural inhibitor Kujarat Tea (Hibiscus sabdarriffa L.) is used which is extracted in aqueous and alcoholic medium, different concentrations (1000،2000, 3000) ppm have been used ; The best concentration found through the results is a conce

... Show More
View Publication Preview PDF
Crossref