Cervical ectropion is considered to be a physiologic condition caused by columnar epithelium migration from the cervical canal into the vaginal portion of the cervix and usually there is no treatement for clinically asymptomatic cervical ectropion . Treatment can be achieved by thermal cauterization (Electrocautery), Cryosurgery or laser vaporization. Aim of the study: To study the effectiveness of CO2 laser (10600nm) in treatment of symptomatic cervical ectropion . Setting: The study was carried out at Laser Medicine Research Clinic at the Institute of Laser for Postgraduate Studies, University of Baghdad between the first of August 2013 to the end of October 2013. Patients and Methods: Ten female Patients with age range between 25-48 years old were collected from Department of Health (Pap smear unit) at Al-Ilwiya Maternity Hospital. Patients who were diagnosed clinically as having cervical ectropion were subjected to Pap smear in order to exclude an underlying dysplasia. The patients were subjected to CO2 laser vaporization in a continuous mode. Results: All patients were subjected to continuous wave laser and the range of power was from 5 up to 10 W. The exposure time ranged from 1-2 minutes according to size of the ectrpion and patient`s cooperation. There was no bleeding nor pain intraoperatively. No bleeding post operatively and all with rapid return to the normal activity . Only patients with Pap smear findings of trichomoniasis or monilia received the appropriate antibiotic treatment before laser ablation. Most patients didn`t require analgesics nor anesthesia and no need for antibiotics postoperatively. Conclusion: CO2 laser vaporization with a power range of 5-10 W (mean power 7.9 W) and exposure time ranged from 1-2 minutes appears to be quite effective for treatment of cervical ectropion .By laser we can go more precise in the tissue and we can reach squamocolumnar junction and destroy the deepest glands and so the whole region can be treated. There is good and rapid healing, insignificant bleeding and pain postoperatively.
Background: Oxidative stress may contribute to the etiology of hypertension in humans. Oxidative stress is an imbalance between reactive oxygen species (ROS) and antioxidant defense mechanisms, causing damage to biological macromolecules and dysregulation of normal metabolism and physiology. Amlodipine as an antihypertensive agent is a long-acting calcium channel blocker that dilates blood vessels and improves blood flow. The aim of this study was to assess the oxidative stress in hypertensive patients on Amlodipine treatment through the assessment of salivary Malondialdehyde (MDA) and superoxide dismutase (SOD) as a marker of oxidative stress.
Mat
... Show MoreIn this study an experimental work was done to study the possibility of using aluminum rubbish material as a coagulant to remove the colloidal particles from oily wastewater by dissolving this rubbish in sodium hydroxide solution. The experiments were carried out on simulated oily wastewater that was prepared at different oil concentrations and hardness levels (50, 250, 500, and 1000) ppm oil for (2000, 2500, 3000, and 3500) ppm CaCo3 respectively. The initial turbidity values were (203, 290, 770, and 1306) NTU, while the minimum values of turbidity that have been gained from the experiments in NTU units were (1.67, 1.95, 2.10, and 4.01) at best sodium aluminate dosages in milliliters (12, 20, 24, and 28) for
... Show MoreBackground: Osteoarthritis (OA) currently seems
inevitable and unavoidable for a large swath of the
population .its etiology relates to a strong ,but
complex ,non mendelian genetic basis ,combined
with mechanical and metabolic factors that cause
molecular alterations the end results of which
affect the whole joint .Glucosamine and
chondrotin sulfate alone or in combination may be
of benefit to a subgroup of individuals who have
knee pain due to OA.
Glucosamine has been shown to alter cartiage turn
over in patients with OA undergoing physical
training
Aim of the study: To find the validity of
glucosamine chondrotin sulfate in treatment of
grade 1 and 2 OA.
Methods: the sample of 280 patients
The effect of number of pulses of pulsed laser on materials is studied analytically, different pulses has been used with the same delay time. The depth of possible damage to the surface of copper and titanium as well as depth of the crater to both materials were considered in this study. The study revealed that linear model is only possible when estimating depth of possible damage for copper material, this means that the depth of possible damage increases with the increment of number of laser pulses .As for titanium material, it is found the relationship is nonlinear. The depth of possible damage of titanium and copper is not the same, and copper seems to be more predictable than titanium.
In an attempt to disposal from nuclear waste which threats our health and environments. Therefore we have to find appropriate method to immobilize nuclear waste. So, in this research the nuclear waste (Strontium hydroxide) was immobilized by Carbon nanotubes (CNTs). The Nd-YAG laser with wave length 1064 nm, energy 750 mJ and 100 pulses used to prepare CNTs. After that adding Sr(HO)2 powder to the CNTs colloidal in calculated rate to get homogenous mixing of CNTs-Sr(OH)2. The Sr(HO)2 absorbs carbon dioxide from the air to form strontium carbonate so, the new solution is CNTs-SrCO3. To dry solution putting three drops from the new solution on the glass slides. To investigate the radi
... Show MoreObjective: Evaluation of the poly ether keton keton polymer (PEKK) coating material on the commercial pure titanium disks (CP Ti) with or without laser surface structuring. Design: In vitro experimental study of PEKK polymer coated material on the CP Ti disks with or without laser surface structuring. Materials and methods: coating the surface of the commercial pure titanium (CP Ti) disks with PEKK polymer was performed via using frictional mode CO2 laser, then the samples disks analyzed by using FESEM. Results: the FESEM reveal good adherence and distribution of the PEKK coated material over the CP Ti substrate by using the frictional mode CO2 laser at 2 watt and 6 ms pulse duration. Conclusion: the frictional mode CO2 laser considered an
... Show MoreZinc sulfide (ZnS) thin films were deposited on glass substrates using pulsed laser deposition technique. The laser used is the Q-switched Nd: YAG laser with 1064nm wavelength and 1Hz pulse repetition rate and varying laser energy 700mJ-1000mJ with 25 pulse. The substrate temperature was kept constant at 100°C. The structural, morphological and optical properties of ZnS thin films were characterized with X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscope (AFM) and UV-VIS spectrophotometer.
Periodontal diseases are inflammatory diseases, for which, scaling and root planning is the main approach. Diode laser therapy as an adjunct to non-surgical periodontal treatment has shown some beneficial effects.
Aim: The objective of this single randomized controlled clinical study was to assess the effect of a 940 nm diode laser as an adjunct to SRP therapy in the treatment of periodontal pockets.
Methods: In this study, twenty patients in need of periodontal treatment with periodontal pocket ≥ 4 mm were selected for this split-mouth clinical study. Test group treated by diode laser 940 nm as an adjunct with SRP, control group treated by SRP in contralateral quadrants. Clinical
... Show MoreThis study presents the effect of laser energy on burning loss of magnesium from the holes' drilled in aluminum alloy 5052. High energy free running pulsed Nd:Glass laser of 300 µs pulse duration has been used to perform the experiments. The laser energy was varied from 1.0 to 8.0 Joules, The drilling processes have been carried out under atmospheric pressure and vacuum inside a specially designed chamber. Microhardness of the blind drilled holes has been investigated .The results indicated that the magnesium loss could be manipulated by adjusting the focusing conditions of the laser beam. Almost, the obtained holes were free of cracks with low taper and low sputter deposition. .The holes performed under atmospheric conditions have high
... Show More