Preferred Language
Articles
/
ijl-46
CO2 Laser Treatment of Cervical Ectropion
...Show More Authors

Cervical ectropion is considered to be a physiologic condition caused by columnar epithelium migration from the cervical canal into the vaginal portion of the cervix and usually there is no treatement for clinically asymptomatic cervical ectropion . Treatment can be achieved by thermal cauterization (Electrocautery), Cryosurgery or laser vaporization. Aim of the study: To study the effectiveness of CO2 laser (10600nm) in treatment of symptomatic cervical ectropion . Setting: The study was carried out at Laser Medicine Research Clinic at the Institute of Laser for Postgraduate Studies, University of Baghdad between the first of August 2013 to the end of October 2013. Patients and Methods: Ten female Patients with age range between 25-48 years old were collected from Department of Health (Pap smear unit) at Al-Ilwiya Maternity Hospital. Patients who were diagnosed clinically as having cervical ectropion were subjected to Pap smear in order to exclude an underlying dysplasia. The patients were subjected to CO2 laser vaporization in a continuous mode. Results: All patients were subjected to continuous wave laser and the range of power was from 5 up to 10 W. The exposure time ranged from 1-2 minutes according to size of the ectrpion and patient`s cooperation. There was no bleeding nor pain intraoperatively. No bleeding post operatively and all with rapid return to the normal activity . Only patients with Pap smear findings of trichomoniasis or monilia received the appropriate antibiotic treatment before laser ablation. Most patients didn`t require analgesics nor anesthesia and no need for antibiotics postoperatively. Conclusion: CO2 laser vaporization with a power range of 5-10 W (mean power 7.9 W) and exposure time ranged from 1-2 minutes appears to be quite effective for treatment of cervical ectropion .By laser we can go more precise in the tissue and we can reach squamocolumnar junction and destroy the deepest glands and so the whole region can be treated. There is good and rapid healing, insignificant bleeding and pain postoperatively.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Reconstruction of 3D Shape for an Object using Laser Scanning Triangulation
...Show More Authors

This paper presents a method of designing and constructing a system capable of acquiring
the third dimension and reconstructs a 3D shape for an object from multi images of that object using
the principle of active optical triangulation. The system consists of an illumination source, a photo
detector, a movement mechanism and a PC, which is working as a controlling unit for the hard ware
components and as an image processing unit for the object multi view raw images which must be
processed to extract the third dimension. The result showed that the optical triangulation method
provides a rapid mean for obtaining accurate and quantitative distance measurements. The final
result's analysis refers to the necessity of usin

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Excision of Soft Tissue Oral Lesions by 810 nm Diode Laser
...Show More Authors

The present study was conducted on 20 patients suffering from different types of lesion like
pyogenic granuloma, peripheral giant cell granuloma, mucoceles, pregnancy tumour, Fordyce's granules
and irritating fibroma.The cases were selected from outpatient clinic of the Al Kydhemya Teaching
Hospital. Patients were treated by diode laser (810±20 nm) at the affected areas of the oral cavity with
continuous contact focused mode until excision of the lesion with coagulation of the oozing area after
excision. Patients were followed up after 2 days, 7 days and 2 weeks to assess healing process and any
post operative complication. Some of undiagnosed lesion sent for histopathological examination. No
serious complications w

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 03 2018
Journal Name
The Iraqi Postgraduate Medical Journal
Operative Treatment by Plate and Screws Versus Conservative Treatment of Closed Displaced Fracture of the Mid Third of Clavicle in Adults: Comparative Study
...Show More Authors

BACKGROUND: Clavicle fractures are common injuries in young active individuals, the mid third of the clavicle is most commonly fractured part(80% of clavicle fracture) OBJECTIVE: To compare the outcomes of operative and non operative management of displaced and or comminuted closed fracture of the mid third of clavicle in young adults PATIENTS AND METHODS: This prospective observational study of 24 patients of fracture of the mid third of the clavicle was conducted in Alkindy teaching hospital from July 2015 to January 2017 and divided into two groups; one managed by operative treatment with plate and screws and the other by non operative sling immobilization after taking the consent and the patients were seen at 2, 4, 6 weeks,3, 6, and 9 m

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 17 2017
Journal Name
Engineering And Technology Journal
Effect of Laser Surface Melting on Chromium Carbide of 304 Stainless Steels
...Show More Authors

SKF Sami I. Jafar, Mohammad J. Kadhim, Engineering and Technology Journal, 2018 - Cited by 4

View Publication Preview PDF
Publication Date
Mon Dec 05 2022
Journal Name
F1000research
Enhancement of surface properties of polyetheretherketone implant material by fractional laser texturing
...Show More Authors

Background: Polyetheretherketone (PEEK) is a promising implant material due to its superior biomechanical strength. However, due to its hydrophobic nature and lack of cellular adhesion properties, it has poor integration with bone tissue. Methods: A fractional CO2 laser was used with various parameters for surface texturing of PEEK substrate to enhance its surface properties. An optical microscope and field-emission scanning electron microscope (FESEM) were used to examine the surface morphology of untextured and laser-textured samples. Energy dispersive X-ray spectroscopy (EDX) was performed to determine the effect of the laser on the microstructure of PEEK. Surface microroughness, atomic force microscopy (AFM), and wettability were invest

... Show More
View Publication Preview PDF
Crossref (4)
Scopus Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-khwarizmi Engineering Journal
Drilling of FR-4 Composite Materials Using Single Pulse of Nd:YAG Laser
...Show More Authors

Laser drilling is capable of producing small, precisely positioned holes with high degree of reproductively. In this paper , IR millisecond Nd:YAG single pulsed laser was used to determine the effect of laser parameters on the drilled hole of the glass - fiber reinforced epoxy composite FR-4 sample of 2 mm in thickness . The type of laser source was GSI lumonics JK760TR Series laser 1.064μm system in a CNC cabin. The JK760TR series has a 0.3-50ms pulse length and a maximum repetition rate 500Hz with an average power of 600W. The investigation of single pulse laser drilling in this paper was based on theoretical and experimental solutions. In single pulse technique, the investigation included focal plane position fpp, pulse shap

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 04 2012
Journal Name
Baghdad Science Journal
Effect of Temperature on Reliability and Degradation of 0.63?m Laser Diode
...Show More Authors

The reliability of optical sources is strongly dependent on the degradation and device characteristics are critically dependent on temperature. The degradation behaviours and reliability test results for the laser diode device (Sony-DL3148-025) will be presented .These devices are usually highly reliable. The degradation behaviour was exhibited in several aging tests, and device lifetimes were then estimated. The temperature dependence of 0.63?m lasers was studied. An aging test with constant light power operation of 5mW was carried out at 10, 25, 50 and 70°C for 100hours. Lifetimes of the optical sources have greatly improved, and these optical sources can be applied to various types of transmission systems. Within this degradation range,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Theoretical Study of The Heating Effect of Laser Radiations on SiUcaGlass Systems
...Show More Authors

A theoretical study has been proposed to investigate the effects of different laser radiations (Nd - glass, DF and C02) as a heating source on different glass samples (Optical glass, Bk - 7 and Soda - lime glass) and different waves lengths (10.6, 3.8, 1.6) ???. The heat changes as which are resulted due irradiation with laser sources have been determined by using the one dimension mathematical relation as a function of time (t) and depth (z). The results of the study show ed that the irradiation with C02 laser had a greater effect than DF laser, while the effects of Nd - glass laser were minimal with a power density of (1.8*10?? w/m2) within atime(l^sec).(Forboth Kinds) The change in the temperatures were not exceeded than (70"K) in all sa

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Minar International Journal Of Applied Sciences And Technology
Electron density spectroscopic measurement in Al laser induced plasma
...Show More Authors

Plasma generated by a 1064 nm pulsed Nd: YAG laser with pulse duration of 10 ns concentrated onto an Al solid target under vacuum pressure was examined spectroscopically. The temperature and electron density specifying the plasma were measured by time-resolved spectroscopy of neutral atom and ion line emissions in the time period range of 300–2000 ns. An echelle spectrograph is utilized to appear the plasma emission lines. The temperature was obtained using the spectral line comparison method and the electron density was calculated using the Stark Broadening (SB) method. The electron density was characterized as a function of laser pulse energy. The time range where the plasma is optically thin and is also in local thermodynamic equilibri

... Show More
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Using He-Ne laser irradiation for enhancing cartilage Autografts
...Show More Authors

thirty adult NewZealand rabbits used in this study, they were divided in to two groups (control and treaded with Helium — Neon laser). A square skin flap done on the medial aspect of the auricle of both sides, a square piece of cartilage incised, pealed out from each auricle and fixed in the site of the other, then the flaps sutured .The site of the operation in the rabbits of the treated group were irradiated using a Helium —Neon laser with (5mw) power for (10 days) began after the operation directly, (3 rabbits) from each group used for collection of specimens for histopathological examination at the weeks (1,2,3,4, & 6) weeks post the operation .The results revealed Early invasion of the matrix with elastic fibers which continue to t

... Show More
View Publication Preview PDF