Preferred Language
Articles
/
ijl-46
CO2 Laser Treatment of Cervical Ectropion
...Show More Authors

Cervical ectropion is considered to be a physiologic condition caused by columnar epithelium migration from the cervical canal into the vaginal portion of the cervix and usually there is no treatement for clinically asymptomatic cervical ectropion . Treatment can be achieved by thermal cauterization (Electrocautery), Cryosurgery or laser vaporization. Aim of the study: To study the effectiveness of CO2 laser (10600nm) in treatment of symptomatic cervical ectropion . Setting: The study was carried out at Laser Medicine Research Clinic at the Institute of Laser for Postgraduate Studies, University of Baghdad between the first of August 2013 to the end of October 2013. Patients and Methods: Ten female Patients with age range between 25-48 years old were collected from Department of Health (Pap smear unit) at Al-Ilwiya Maternity Hospital. Patients who were diagnosed clinically as having cervical ectropion were subjected to Pap smear in order to exclude an underlying dysplasia. The patients were subjected to CO2 laser vaporization in a continuous mode. Results: All patients were subjected to continuous wave laser and the range of power was from 5 up to 10 W. The exposure time ranged from 1-2 minutes according to size of the ectrpion and patient`s cooperation. There was no bleeding nor pain intraoperatively. No bleeding post operatively and all with rapid return to the normal activity . Only patients with Pap smear findings of trichomoniasis or monilia received the appropriate antibiotic treatment before laser ablation. Most patients didn`t require analgesics nor anesthesia and no need for antibiotics postoperatively. Conclusion: CO2 laser vaporization with a power range of 5-10 W (mean power 7.9 W) and exposure time ranged from 1-2 minutes appears to be quite effective for treatment of cervical ectropion .By laser we can go more precise in the tissue and we can reach squamocolumnar junction and destroy the deepest glands and so the whole region can be treated. There is good and rapid healing, insignificant bleeding and pain postoperatively.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed May 17 2023
Journal Name
Journal Of Engineering
Performance Evaluation of Al-Rustamiya Wastewater Treatment Plant
...Show More Authors

Al-Rustamiya sewage treatment plant (WWTP) serves the east side of Baghdad city (Rusafa) and is considered one of the largest projects.It consists of three parts (old project F0, first extension F1, and second extension F2) that treat wastewater and the
effluent is discharged into Diyala river and thus into the Tigris River. These plants are designed and constructed with an aim to manage wastewater to reachIraqi effluent standard for BOD5, COD, TSS and chloride concentrations of 40, 100, 60 and 600
mg/L respectively. The data recordedfrom March till December 2011 provided from Al-RustamiyaWWTP, were considered in this study to evaluate the performance of the plant. The results indicated that the strength of the wastewater enterin

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Treatment of Recurrent Aphthous Ulceration by Mastic Orabase
...Show More Authors

Background: Recurrent aphthous ulcer is a chronic inflammatory disease of the oral mucosa. Substance P has activity in the inflammatory response. Transforming growth factor beta (TGF-β) as immune-modulators regulates the immune response and has anti-inflammatory, pro-inflammatory effects. Pistacia lentiscus (mastic) of Anacardiaceae family have pharmacological activities like anti-inflammatory, antioxidant, and used in treatment of wound and repair. The aim of this study is to find the safety and efficacy of a new product mastic orabase; experimentally and clinically. Methods: This research studied two parts: first; experimentally for assessment of mastic orabase effects on rabbit dermal irritation, efficacy of mastic orabase on the indu

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Sep 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Treatment of Slack Wax by Thermal Cracking Process
...Show More Authors

This work deals with thermal cracking of slack wax produced as a byproduct from solvent dewaxing process of medium lubricating oil fraction in AL-Dura refinery. The thermal cracking process was carried out at a temperature ranges 480-540 ºC and atmospheric pressure. The liquid hourly space velocity (LHSV) for thermal cracking was varied between 1.0-2.5 . It was found that the conversion increased (61 - 83) with the increasing of reaction temperature (480 - 540) and decreased (83 - 63) with the increasing of liquid hourly space velocity (1.0 - 2.5).
The maximum gasoline yield obtained by thermal cracking process (48.52 wt. % of feed) was obtained at 500 ºC and liquid hour space velocity 1 . The obtaining liquid product at the best op

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Modified Mathematical Model of Tumor Treatment by Radiotherapy
...Show More Authors

In this research, a mathematical model of tumor treatment by radiotherapy is studied and a new modification for the model is proposed as well as introducing the check for the suggested modification. Also the stability of the modified model is analyzed in the last section.

View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Wed Mar 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Treatment of Used lubricant Oil by Solvent Extraction
...Show More Authors

This study investigates the treatment of used lubricating oils from AL-Mussaib Gas Power Station Company-Iraq, which was treated with different extractive solvents (heptane and 2-propanol). The performance activity of these solvents in the extraction process was examined and evaluated experimentally. Operating parameters were solvent to oil ratios of (1:2, 1:4, 1:6, and 1:8), mixing time (20, 35, 50, and 65 min), temperatures (30, 40, 50, and 60 ºC), and mixing speed (500 rpm). These parameters were studied and analyzed. The quality is determined by the measuring and assessment of important characteristics specially viscosity, viscosity index, specific gravity, pour point, flash point, and ash content. The results confirm that the

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Mar 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Treatment of Used lubricant Oil by Solvent Extraction
...Show More Authors

This study investigates the treatment of used lubricating oils from AL-Mussaib Gas Power Station Company-Iraq, which was treated with different extractive solvents (heptane and 2-propanol). The performance activity of these solvents in the extraction process was examined and evaluated experimentally. Operating parameters were solvent to oil ratios of (1:2, 1:4, 1:6, and 1:8), mixing time (20, 35, 50, and 65 min), temperatures (30, 40, 50, and 60 ºC), and mixing speed (500 rpm). These parameters were studied and analyzed. The quality is determined by the measuring and assessment of important characteristics specially viscosity, viscosity index, specific gravity, pour point, flash point, and ash content. The results confirm that the solve

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
Effect of the electric field on drilling Brass by Laser
...Show More Authors

The research include a pulsed Nd: YAG Laser with (300µs) pulse duration in the TEM00 mode at (1.06µm) wavelength for energies between (0.5-3) J was employed to drill Brass material which is use in industrial applications. The process of drill was assisted by an electric field. This resulted in an increase in the hole aspect ratio by the value (45%) and decrease in the hole taper by the value (25%) of its value under ordinary drilling conditions using the same input energy.

View Publication Preview PDF
Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
Intraoral Repair of Dental Ceramics Using Er,Cr:YSGG Laser: Review
...Show More Authors

Introduction: All-ceramic crowns are widely used in prosthodontics and cosmetic dentistry due to their good esthetic and proper physical properties. Chipping of ceramic is one of the most common post-insertion complications, that can be fixed either extraoral or intraorally. The latter is time time-effective alternative, less traumatic, and low-cost. A newer objective method of laser is a surface modification of ceramics to increase surface roughness. The aim of this study is to provide a review of Er,Cr;YSGG (2960nm) in intraoral repair and shear bond strength (SBS). Method: A thorough search considering Google Scholar and PubMed published data and ten articles found wh

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Electronic diagnostics system for the analysis of laser beam profile
...Show More Authors

In this work the analysis of laser beam profile system ,using a two dimensional CCD (Charge Coupled Device) arrays, is established. The system is capable of producing video graphics that give a two dimensional image of laser beam. The video graphics system creates color distribution that represent the intensity distribution of the laser beam or the energy profile of the beam. The software used is capable of analyzing and displaying the profile in four different methods that is , color code intensity contouring , intensity shareholding, intensity cross section along two dimension x-y, and three dimensional plot of the beam intensity given in the same display.

View Publication Preview PDF
Publication Date
Mon Dec 10 2007
Journal Name
Iraqi Journal Of Laser
Evaluation of breast mass excision by 810 nm diode laser
...Show More Authors

Breast mass is by far the most important clinical problem that concerns the breast today. This study was carried out to evaluate diode laser as a cutting tool in breast mass excision and as a hemostatic tool for coagulation during surgery. Using 810 nm diode laser with optical fiber 600μm in diameter of conical tip, udder (cow's breast) tissue, and three female patients (mean age of 35.5 y with clinically palpable breast mass) had been used in this study. The patients were followed up regularly postoperatively. In preliminary work on udder tissue, the power needed for cutting and excision was 15W (power density= 5.3 kW/cm2). The time consumed for excision of a piece of udder tissue, 40×10×3 mm in dimensions was 5 min. The depth range

... Show More
View Publication Preview PDF