Cervical ectropion is considered to be a physiologic condition caused by columnar epithelium migration from the cervical canal into the vaginal portion of the cervix and usually there is no treatement for clinically asymptomatic cervical ectropion . Treatment can be achieved by thermal cauterization (Electrocautery), Cryosurgery or laser vaporization. Aim of the study: To study the effectiveness of CO2 laser (10600nm) in treatment of symptomatic cervical ectropion . Setting: The study was carried out at Laser Medicine Research Clinic at the Institute of Laser for Postgraduate Studies, University of Baghdad between the first of August 2013 to the end of October 2013. Patients and Methods: Ten female Patients with age range between 25-48 years old were collected from Department of Health (Pap smear unit) at Al-Ilwiya Maternity Hospital. Patients who were diagnosed clinically as having cervical ectropion were subjected to Pap smear in order to exclude an underlying dysplasia. The patients were subjected to CO2 laser vaporization in a continuous mode. Results: All patients were subjected to continuous wave laser and the range of power was from 5 up to 10 W. The exposure time ranged from 1-2 minutes according to size of the ectrpion and patient`s cooperation. There was no bleeding nor pain intraoperatively. No bleeding post operatively and all with rapid return to the normal activity . Only patients with Pap smear findings of trichomoniasis or monilia received the appropriate antibiotic treatment before laser ablation. Most patients didn`t require analgesics nor anesthesia and no need for antibiotics postoperatively. Conclusion: CO2 laser vaporization with a power range of 5-10 W (mean power 7.9 W) and exposure time ranged from 1-2 minutes appears to be quite effective for treatment of cervical ectropion .By laser we can go more precise in the tissue and we can reach squamocolumnar junction and destroy the deepest glands and so the whole region can be treated. There is good and rapid healing, insignificant bleeding and pain postoperatively.
Spray pyrolysis technique was used to make Carbon60-Zinc oxide (C60-ZnO) thin films, and chemical, structural, antibacterial, and optical characterizations regarding such nanocomposite have been done prior to and following treatment. Fullerene peaks in C60-ZnO thin films are identical and appear at the same angles. Following the treatment of the plasma, the existence regarding fullerene peaks in the thin films investigated suggests that the crystallographic quality related to C60-ZnO thin films has enhanced. Following plasma treatment, field emission scanning electron microscopy (FESEM) images regarding a C60-ZnO thin film indicate that both zinc oxide and fullerene particles had shrunk in the size and have an even distribution. In addition
... Show MoreBackground: Diabetic mellitus type ? is a metabolic disorder of diverse etiological factors, characterized by hyperglycemia resulting from an absolute deficiency of insulin affected childhood and adolescent. Some of these patients seek an orthodontic care .The orthodontist who is treating these medically compromised patients should have a working knowledge of the multitude of medically complex problems. This information will support and enable for delivery of high standards of dental care in general and orthodontic care in particular. The aim of this study was to analyze serum IgG levels and salivary secretory IgA (sIgA) levels in human dentine extract (HDE) before (T0) and 6 months after (T6) orthodontic treatment and to correlate anti-HDE
... Show MoreIn addition to the primary treatment, biological treatment is used to reduce inorganic and organic components in the wastewater. The separation of biomass from treated wastewater is usually important to meet the effluent disposal requirements, so the MBBR system has been one of the most important modern technologies that use plastic tankers to transport biomass with wastewater, which works in pure biofilm, at low concentrations of suspended solids. However, biological treatment has been developed using the active sludge mixing process with MBBR. Turbo4bio was established as a sustainable and cost-effective solution for wastewater treatment plants in the early 1990s and ran on minimal sludge, and is easy to maintain. This
... Show MoreKE Sharquie, HR Al-Hamamy, AA Noaimi, AF Tahir, Journal of Cosmetics, Dermatological Sciences and Applications, 2012 - Cited by 2
Abstract
At any moment, the continuous usage of medications can accompanied by DNA damage and the accumulation of such damages can cause serious consequences. Antidepressants are long-term used drugs and the incidence of their genotoxic impacts cannot be excluded. Therefore, this work was designed to investigate the possible genotoxic effects of the commonly used antidepressants (fluoxetine and amitriptyline) in adult male rats.
Detection of DNA damage in individual cells was assessed by comet and micronucleus assays in three different cell populations i.e. liver, testis and bone marrow tissues of 24 swiss albino adult male rats. The animals were randomly allocated into three groups of 8 rats ea
... Show MoreIt is found that hypersensitive teeth have a larger number and wider patent tubules than those of non-sensitive teeth. Objective: The aim of this study is to compare between the effects of diode laser at different power densities, with and without sodium fluoride on the sealing of exposed dentinal tubules and dentin permeability. Materials and methods: 118 teeth were used. Samples were divided into three major groups. The first consisted of 100 teeth used for permeability test. The second consisted of 16 teeth for measuring external surface temperature elevation while irradiation. The third, in turn, consisted of one pair of teeth observed under SEM for dentine surface morphology analysis. Results: For dentin permeability measurement, th
... Show MoreAbstract: The aim of this study is to assess the effectiveness of 940 nm diode laser in comparison to Endoactivator in elimination of smear layer in terms of radicular dentin permeability and ultra-structural changes of root canal walls by SEM evaluation. Twenty-eight single-rooted extracted lower premolars were instrumented up to size X4 (protaper Next, Dentsaply) and divided into two experimental groups according to the irrigation system, G1; activated by EndoActivator and G2; activated by Diode laser 940 nm, CW mode, 1.7 W. Afterward, the roots were made externally impermeable, filled with 2%methylene blue dye, divided horizontally into three segments representing the apical, middle, and coronal thirds then examined under stereo- micr
... Show MoreThe aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in
... Show MoreInfrared photoconductive detectors working in the far-infrared region and room temperature were fabricated. The detectors were fabricated using three types of carbon nanotubes (CNTs); MWCNTs, COOH-MWCNTs, and short-MWCNTs. The carbon nontubes suspension is deposited by dip coating and drop–casting techniques to prepare thin films of CNTs. These films were deposited on porous silicon (PSi) substrates of n-type Si. The I-V characteristics and the figures of merit of the fabricated detectors were measured at a forward bias voltage of 3 and 5 volts as well as at dark and under illumination by IR radiation from a CO2 laser of 10.6 μm wavelengths and power of 2.2 W. The responsivity and figures of merit of the photoconductive detector
... Show More