Laser etching may be an alternative to acid etching of enamel and dentin. Several characteristics of irradiated dental hard tissues have been considered advantageous, microscopically rough surfaces without demineralization, open dentinal tubules without smear layer production and dentin surface sterilization. The aim of this study is to determine and compare histology the microleakage in class V cavity restored with a light cured composite after conditioning the samples(tooth surface) with 1-acid etching, 2-Q-switched Nd:YAG Laser etching and finally 3- acid and laser etching. Materials and methods: Twenty four non carious human extracted teeth were used in this study. The samples were equally grouped into four groups of six teeth each. A class V cavity was prepared. In group I, tooth surface was etched with a 37% phosphoric acid gel. In group II, the tooth surface was conditioned using a pulsed Nd:YAG Laser alone with a wavelength of 532 nm. The parameters were of pulse energy 60 mJ, pulse repetition rate 6Hz and energy density was 0.48 J/cm2. In group III, the tooth surface was treated with Nd: YAG Laser and then was etched with phosphoric acid. In group IV, the surface was treated with 37% phosphoric acid then irradiated with Nd: YAG Laser; with the same parameters and concentration mentioned in group I and II. The samples immersed in 1% basic fuschin dye to mimic the normal stains in oral cavity and the sections were examined by a stereomicroscope and the readings were scored. Results: The results showed that group IV, in which the surface was treated with 37% phosphoric acid and then irradiated with Nd: YAG Laser) recorded the least microleakage of the four groups, where group III, in which the tooth surface was treated with Nd: YAG Laser and then was etched with phosphoric acid)recorded reasonable results better than group I (group I tooth surface was etched with a 37% phosphoric acid gel) or group II , in which the tooth surface was conditioned using a pulsed Nd:YAG Laser alone) Conclusion: The use of Q-switched Nd:YAG laser in etching the tooth surface was so effective that it can be used in treating or conditioning the tooth surface to enhance bonding and the best parameters among the tested samples were pulse energy of 60mJ, pulse repetition rate of 6Hz and energy density 0.48 J/cm2.
This histological study was carried out to compare between the thyroid gland of mice (as a model of the mammals) and the thyroid tissue of fish. Unlike mice, the thyroid gland of fish can't be recognized by naked eye. The present study revealed that the thyroid of mice varied from that of fish by the location and the histological structure. The study classified the physiological state of the thyroid of mice into three states and that of the fish into only two states. Accordingly, the study concluded that the metabolism of thyroid fish was of moderate type.
The present study aimed to investigate the anatomical and histological, aspects of the stomach in two different Iraqi birds, (common wood pigeon, Columba palumbus (herbivorous) and the barn owl, Tyto alba (carnivorous). Stomach in the two studied birds IS divided into two parts, glandular or true stomach (proventriculus) and the muscular stomach or gizzard (ventriculus). Proventriculus in the common wood pigeon appeared as fusiform shaped tube and separated from the gizzard by isthmus while in the barn owl, it was pearsshaped , wider and shorter than that of the common wood pigeon and not separated from the gizzard by isthmus. In common wood pigeon, gizzard appeared as biconvex lens lining with yellowish green tissue, the koilin , while
... Show MoreTwo Prototypes of Transversely Excited at atmospheric pressure (TEA) Nitrogen laser systems (One Stage Blumlein Circuit and Two Stage Blumlein Circuit) were fabricated and operated. High voltage power supply with variable operating voltage (0-20 kv) and operating current (1-3A) was built and tested successfully. The gas flow rate of 15 L/ min and 10 L/ min for OSBC and TSBC was used. The performance of the fabricated systems was studied extensively reaching to the optimum operating conditions. The obtained laser output energy for the first system has linear relationship with the applied voltage. The maximum output energy was about (1.14 mJ) with (10.40) ns pulse duration and the half-wave divergence angle was about (0.1455 m rad). In the
... Show MoreIn this paper, an experimental study has been conducted regarding the indication of resonance in chaotic semiconductor laser. Resonant perturbations are effective for harnessing nonlinear oscillators for various applications such as inducing chaos and controlling chaos. Interesting results have been obtained regarding to the effect of the chaotic resonance by adding the frequency on the systems. The frequency changes nonlinear dynamical system through a critical value, there is a transition from a periodic attractor to a strange attractor. The amplitude has a very relevant impact on the system, resulting in an optimal resonance response for appropriate values related to correlation time. The chaotic system becomes regular under
... Show MoreTooth restoration one of the most common procedures in dental practice. The replacement of the entire restoration leads to loss of tooth structure and increase risk of pulp injury; replacement is also time consuming and costly. According to the minimally invasive approach when minimal defects, repair is the better choice than the total replacement of the restoration. This study aims to evaluate repair rating versus replacement treatment procedure for defective composite fillings among Iraqi dentists. Material and methodology: A questionnaire survey were designed and distributed to 184 post-graduate dentists in Iraq. The inquiry pertained general information; including their clinical experience in years, their preference in terms of direct c
... Show MoreThis study used a continuous photo-Fenton-like method to remediate textile effluent containing azo dyes especially direct blue 15 dye (DB15). A Eucalyptus leaf extract was used to create iron/copper nanoparticles supported on bentonite for use as catalysts (E@B-Fe/Cu-NPs). Two fixed-bed configurations were studied and compared. The first one involved mixing granular bentonite with E@B-Fe/Cu-NPs (GB- E@B-Fe/Cu-NPs), and the other examined the mixing of E@B-Fe/Cu-NPs with glass beads (glass beads-E@B-Fe/Cu-NPs) and filled to the fixed-bed column. Scanning electron microscopy (SEM), zeta potential, and atomic forces spectroscopy (AFM) techniques were used to characterize the obtained particles (NPs). The effect of flow rate and DB15 concent
... Show MoreThis work has been done with using of epoxy resin mixed with Granite powder were weighted by percent volume (5,10,15, and 20)%and then mixed with epoxy polymer to compose polymer composite. Hand lay-up technique is used in fabrication of the composite samples. Hardness test was carried out for the proper samples in both normal condition and after immersion in HCL (1 M and 2 M) solutions for periods ranging up to 10 weeks. After comparing the results between the polymer and their composite, the hardness increased with increasing Granite weight percent, it was found that Hardness were greater for the composites before immersion compared with their values after immersion.
The daily practices of humans produce various types of waste, which are a threat to the health and environment surrounding it, especially after the increase in quantities as a result of population growth and technological development, and here came the need for recycling solid waste as one of the modern concepts that achieve environmental benefits, The aim of the research is to evaluate the project of sorting and recycling of solid waste in the district of Mahmoudiya and whether its work is sustainable ,Conforming to modern standards, using standard checklists to determine the gap between the current laboratory reality and the requirements of those standards , Using the case study methodology as the most appropriate approach
... Show MoreThis study aims to fabricate and assess the β-tricalcium phosphate (β-TCP) bioactive ceramic coat layer on bioinert ceramic zirconia implants through the direct laser melting technique by applying a long-pulsed Nd:YAG laser of 1064 nm. Surface morphologies, adherence, and structural change in the coatings were evaluated by optical microscopy, field emission scanning electron microscope, hardness, and x-ray diffractometer. The elastic modulus (EM) of the coating was also determined using the nanoindentation test. The quality of the coating was improved when the laser power was 90 W with a decrease in the scan speed to 4 mm s−1. The chemical composition of the coat was maintained after laser processing; also, the Energy Dispersive
... Show More