Preferred Language
Articles
/
ijl-44
Acne Scar Management by Fractional CO2 Laser
...Show More Authors

Acne scars are one of the most common problems following acne vulgaris. Despite the extensive list of available treatment modalities, their effectiveness depends upon the nature of the scar. Ablative lasers had been used to treat acne scars; one of them is the fractional CO2 laser. The aim of this study is to evaluate the outcome of fractional CO2 laser in the treatment of acne scars. Methods: Since January 2010 to June 2013, using 10600 nm fractional CO2 laser beams, the acne scar of 400 patients, 188 males and 212 females, mean age of 34 years, have been treated and classified according to severity into four grades following Goodman and Baron classification. Each patient underwent 3-5 sessions once monthly. The mean laser exposure time was 15 minutes, mean operative time was 1-1.5 hours, no hospital stay and the treatment coarse lasted 3-5 months. Patients were followed up for about one year to evaluate the success of the procedure. Results: Investigators and patients graded the improvement on a scale (0=no improvement to grade1 0-25%, grade 2, 25-50% ,grade 3 50-75%,grade 4 more than 75%. Both investigators and patients gave mean improvement scores in the range of 50% to 75% for scar depth, scar margins beveling, better color match, texture, skin tightness and overall improvement of the patients well looking. The degree of improvement increased with each treatment session and continued to increase between the 1-month and 3-month after the last treatment. Conclusion Fraction ablative resurfacing seems to hit a sweet spot between the minimal benefits of traditional nonablative laser treatment and the considerable downtime and complications of ablative resurfacing.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 01 2008
Journal Name
Iraqi Journal Of Physics
Effect of Nd-YAG, XeCl, and Nitrogen Laser Radiation on Human Aorta , and Some Arterial Tissues
...Show More Authors

The effect of laser radiation on human aorta, coronary, and pulmonary arteries, and pulmonary veins has been investigated. Xenon-Chloride (eximer), Nitrogen, and Nd-YAG pulsed lasers of wavelengths 308, 337, and 1060 nm respectively were used. Their effects on fresh postmortem tissues, normal and diseased, was studied. The diameter and depth of ablation of the exposed tissues, in air, were measured as a function of many factors related to the type of laser and nature of the tissue. The effect of properties of the applied lasers, such as average power density and deposited energy density, on the exposed tissue surface were studied. The increase of these two parameters cause an increase in the depth and diameter of ablation. However the di

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Iraqi Journal Of Physics
Optimum diameter for laser beam and effect of temperature rise on the optical bistability hysteresis loops
...Show More Authors

 In this research, analytical study for simulating a Fabry-Perot bistable etalon (F-P cavity) filled with a dispersive optimized nonlinear optical material (Kerr type) such as semiconductors Indium Antimonide (InSb). An optimization procedure using reflective (~85%) InSb etalon (~50µm) thick is described. For this etalon with a (50 µm) spot diameter beam, the minimum switching power is (~0.078 mW) and switching time is (~150 ns), leading to a switching energy of (~11.77 pJ) for this device. Also, the main role played by the temperature to change the etalon characteristic from nonlinear to linear dynamics.

View Publication Preview PDF
Crossref
Publication Date
Tue Dec 27 2022
Journal Name
Journal Of Lasers In Medical Sciences
Influence of Fiber Laser (1064 nm) on Shear Bond Strength of Titanium Abutment and Resin Cement
...Show More Authors

Introduction: The present study was performed to evaluate the influence of a 1064 nm fiber laser on shear bond strength (SBS) at the interface of titanium and resin cement. Methods: Forty titanium discs of 6 mm × 3 mm (diameter and thickness respectively) were categorized into four groups (n=10): control group without any surface treatment and three groups treated with a fiber laser with 81 ns pulse duration, 30 kHz frequency, 10000 mm/s scanning speed, 0.05 mm spot size, and different average power values (3, 5 and 7 W) depending on the tested group. Titanium disc characterization was performed by the scanning electron microscope (SEM) and surface roughness tester. Phase analysis was achieved using an X-ray diffractometer (XRD). F

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Effect of Low Energy Laser on the Healing of Tooth Extraction Wound: (Histological Study in Rat)
...Show More Authors

Aims: This study was done to investigate the effect of low energy laser therapy on bone healing at the extraction site. Materials and methods:(24) male albino rats were exposed to the extraction procedure of the maxillary first molar on the first day of a seven day experiment and these animals were divided into two main groups; the control group and the laser group. The laser experiment involved using (Ga-As infrared diode laser) from optodent by directing the probe over the extraction site. The control group consisted of 4 rats, and the laser group was subdivided into 5 subgroups of 4 rats each. The laser dose was as follows: B1: a single dose of 5 minutes immediately after extraction.,

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Design Considerations of Laser Source in a Ring Network Based on Fiber Distributed Data Interface (FDDI)
...Show More Authors

This work presents the use of laser diode in the fiber distributed data interface FDDI networks. FDDI uses optical fiber as a transmission media. This solves the problems resulted from the EMI, and noise. In addition it increases the security of transmission. A network with a ring topology consists of three computers was designed and implemented. The timed token protocol was used to achieve and control the process of communication over the ring. Nonreturn to zero inversion (NRZI) modulation was carried out as a part of the physical (PHY) sublayer. The optical system consists of a laser diode with wavelength of 820 nm and 2.5 mW maximum output power as a source, optical fiber as a channel, and positive intrinsic negative (PIN) photodiode

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Writing of a Bragg Grating on a D-shaped Optical Fiber Using the KrF Excimer Laser
...Show More Authors

Fiber Bragg Grating has many advantages where it can be used as a temperature sensor, pressure sensor or even as a refractive index sensor. Designing each of this fiber Bragg grating sensors should include some requirements. Fiber Bragg grating refractive index sensor is a very important application. In order to increase the sensing ability of fiber Bragg gratings, many methods were followed. In our proposed work, the fiber Bragg grating was written in a D-shaped optical fiber by using a phase mask method with KrFexcimer. The resultant fiber Bragg grating has a high reflectivity 99.99% with a Bragg wavelength of 1551.2 nm as a best result obtained from a phase mask with a grating period of 1057 nm. In this work it was found that the rota

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 05 2024
Journal Name
Scientific Reports
Mesoporous Ag@WO3 core–shell, an investigation at different concentrated environment employing laser ablation in liquid
...Show More Authors
Abstract<p>In this study, silver-tungsten oxide core–shell nanoparticles (Ag–WO<sub>3</sub> NPs) were synthesized by pulsed laser ablation in liquid employing a (1.06 µm) Q-switched Nd:YAG laser, at different Ag colloidal concentration environment (different core concentration). The produced Ag–WO<sub>3</sub> core–shell NPs were subjected to characterization using UV–visible spectrophotometry, X-ray diffraction (XRD), transmission electron microscopy (TEM), energy-dispersive spectroscopy, electrical analysis, and photoluminescence PL. The UV–visible spectra exhibited distinct absorption peaks at around 200 and 405 nm, which attributed to the occurrence of surface Plasmon reson</p> ... Show More
View Publication
Scopus (15)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Tue Aug 13 2024
Journal Name
Brazilian Dental Science
Poly ether keton keton polymer deposition on laser surface structured commercial pure titanium using magnetron sputtering
...Show More Authors

Objective: This study aimed to evaluate the effect of coating titanium (Ti) dental implant with polyether ketone ketone (PEKK) polymer using magnetron sputtering on osseointegration, trying to overcome some of the problems associated with Ti alloys. Material and Methods: Implants were prepared from grade (II) commercially pure titanium (CP Ti), then laser was used to induce roughness on the surface of Ti. PEKK was deposited on the surface of Ti implants by radiofrequency (RF) magnetron sputtering technique. The implants were divided in to three groups: without coating (Ls), with PEKK coating using argon (Ar) as sputtering gas (Ls-PEKK-Ar), and with PEKK coating using nitrogen (N) as sputtering gas (Ls-PEKK-N). All the implants were implante

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Fri Jul 25 2014
Journal Name
Modern Sport
Analyze study for some biomechanics variables to jump shoot skill from different spots with and without defense to basketball youth players in 3x3
...Show More Authors

The research to knows some biomechanics variables in different spots with and without players in basketball youth players and analysis by using destructive method in surfing study and the research were applied for jump shoot from one of basketball players in ( middle , left , right ) in side zone and out of zone also from three point shoot with and without defense and we depend on successful shoot on analyze .The results and conclusions that center of weight of the player on standby on high and knee angel and hips were more wide also the two angle of wrist , elbow on start of shooting be more wide with defender more than without defender .the maximum high center of weight and shooting angle and ball entrance being less degree with defender

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
مجلة علوم الرياضة في جامعة ديالى
إتخاذ القرار و علاقته بإنماط الشخصية و الإدراك البنائي لدى مدراء منتديات الشباب و الرياضة في محافظات الفرات الأوسط و الجنوبية.
...Show More Authors