Preferred Language
Articles
/
ijl-43
Treatment of Skin Hyperpigmentation using Q-Switched (1064nm and 532nm) Nd:YAG Laser
...Show More Authors

Hyperpigmentation is the increase in the natural color of the skin. The purpose of this study is to evaluate the efficacy and safety of Q-Switched Nd:YAG (1064 & 532 nm) Laser in treatment of skin hyper pigmentation. This study was done in the research clinic of Institute of laser for postgraduate Studies/University of Baghdad from October 2008 to the end of January 2009. After clinical assessment of skin hyperpigmentation color, twenty six patients were divided according to their lesions. Eight Patients with freckles, seven patients with melasma, four patients with tattoo. Cases with tattoo, were subdivided into amateur tattoos two, professional tattoos one, and one traumatic tattoo. Four Patients with post inflammatory hyperpigmentation, one patient with gazzal eye, one patient with spilus nevus, one patient with becker's nevus. The time of treatment session was from 5-20 minutes according to the size of lesion at 3-4 week interval. The distributions of lesions were on different part of body, face, hand, forearm, and back. Twenty two patients completed the study; four patients defaulted from the study for unknown reasons. Conclusion: The use of Q-Switched lasers offers a low risk, effective therapy with minimal side effects because they offer bloodless, low risk, effective treatment, Q-Switched Nd:YAG lasers have replaced other methods and are now considered standard treatment. The Q-Switched Nd:YAG laser have great advantages in removing hyperpigmentation, its longer wavelength (1064nm) would increase dermal penetration and decrease melanin absorption so that it’s used in skin type (III,IV,V,VI) without the risk of depigmentation or hypopigmentation.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 21 2025
Journal Name
Revista Iberoamericana De Psicología Del Ejercicio Y El Deporte, Issn 1886-8576, Vol. 16, Nº. 3, 2021
The effect of a rehabilitation program using a tens device for the treatment of pain and impaired mobility of the wrist and limbs joint in basketball players
...Show More Authors

Autorías: Hadeer Idan Ghanim, Ishraq Mahmood. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 3, 2021. Artículo de Revista en Dialnet.

View Publication Preview PDF
Scopus
Publication Date
Tue May 05 2015
Journal Name
International Journal Of Research In Pharmacy And Chemistry
NEW APPROACH FOR DETERMINATION OF MEBEVERINE BY QUENCHED FLUORESCENCE OF ANALYTICALLY INTERESTED SPECIES USING CONTINUOUS FLOW INJECTION LASER DIODE FLUORIMETER ANALYSER
...Show More Authors

The proposed method is sensitive, simple , fast for the determination of mebeverine hydrochloride in pure form or in pharmaceutical dosage . Using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. Where it is based upon the fluorescence of fluorescein sodium salt and quenching effect of fluorescence by mebeverine in aqueous medium. The calibration graph was linear in the concentration range 0.05 to10 mMol.L-1 (r= 0.9629) with relative standard deviation (RSD%) for 1 mMol.L-1mebeverine solution was lower than 3% (n=6). Three pharmaceutical drugs were used as an application for the determination of mebeverine. A comparison was made between the newly developed method of analysis wit

... Show More
View Publication
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Engineering Science And Technology (jestec)
Predicting Municipal Sewage Effluent Quality Index Using Mathematical Models In The Al-Rustamiya Sewage Treatment Plant
...Show More Authors

Efficient management of treated sewage effluents protects the environment and reuse of municipal, industrial, agricultural and recreational as compensation for water shortages as a second source of water. This study was conducted to investigate the overall performance and evaluate the effluent quality from Al- Rustamiya sewage treatment plant (STP), Baghdad, Iraq by determining the effluent quality index (EQI). This assessment included daily records of major influent and effluent sewage parameters that were obtained from the municipal sewage plant laboratory recorded from January 2011 to December 2018. The result showed that the treated sewage effluent quality from STP was within the Iraqi quality standards (IQS) for disposal and t

... Show More
Publication Date
Sun Jun 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance of Subsurface Flow Constructed Wetland Systems in the Treatment of Al-Rustumia Municipal Wastewater using Continuous Loading Feed
...Show More Authors

This study aimed at comparing the performance of vertical, horizontal and hybrid subsurface flow systems in secondary treatment for the effluent wastewater from the primary basins at Al-Rustumia wastewater treatment plant, Baghdad, Iraq. The treatments were monitored for six weeks while the testsduration were from 4 to 12 September 2018 under continuous wastewater feeding for chemical oxygen demand (COD), total suspended solid (TSS),ammonia-nitrogen(NH4-N) and phosphate (PO4-P) in comparison with FAO and USEPA standards for effluent discharge to evaluate the suitability of treated water for irrigation purposes. Among the systems planted with Phragmites Australia, the hybrid subsurface flow system which cons

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Design and study for transmitter system of laser Nd-YAG (1.06 ?m)
...Show More Authors

In this research , design and study a (beam expander) for the Nd – YAG laser with (1.06 ?m) Wavelength has been studied at 5X zoom with narrow diversion in the room temperature. by using (ZEMAX) to study the system. Evaluate its performance via (ZEMAX) outputs, as bright Spot Diagram via (RMS), Ray Fan Plot, Geometric Encircled Energy and the value of Focal shift. Then study the effect of field of view on the outputs in the room temperature.

View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2013
Journal Name
International Journal Of Science And Technology (ijst)
Study of Optical and Structures for TiO2 prepared by Pulse Laser Deposition
...Show More Authors

Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Spectroscopic and structural properties of Zinc-Phthalocyanine prepared by pulsed laser deposition
...Show More Authors

View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Preparation and characterization of colloidal CdTe nanoparticles by laser ablation in liquids
...Show More Authors

Nanoparticles generation by laser ablation of a solid target in a liquid environment is an easy method. Cadmium Telluride (CdTe) colloidal nanoparticles have been synthesized by laser ablation Nd:YAG with wavelengths of 1064nm and double frequency at 532 nm, number of pulses 50 pulses, with pulse energy= 620mJ, 700mJ of a solid target CdTe is immersed in double distilled deionized water (DDIW) and in methanol liquid. Influences of the laser energy and different solutions on the formation and optical characterization of the CdTe nanoparticles have been studied using atomic force microscope (AFM) and the UV-Vis absorption. As a results, it leads to the absorbance in UV-Vis spectra of samples prepared in water at laser wavelength of 532nm i

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Spatial Response Uniformity of Silicon–Based CdS and PbS Heterojunction Laser Detectors
...Show More Authors

This paper demonstrates the spatial response uniformity (SRU) of two types of heterojunctions (CdS, PbS /Si) laser detectors. The spatial response nonuniformity of these heterojunctions is not significant and it is negligible in comparison with p+- n silicon photodiode. Experimental results show that the uniformity of CdS /Si is better than that of PbS /Si heterojunction

View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Gamma ray effect on the properties of R590 and C480 laser dyes
...Show More Authors

In the current research, we investigated the absorption spectrum for R590 and C480 dyes in ethanol solvent for different dye solution concentrations of 10-4, 10-5 and 10-6M. These dyes have been prepared and studied before and after gamma irradiation (first, second ionization) using cesium-137 source with absorbed doses of 18.36 Gy (time exposure of 10 days) and 73.44 Gy (with time exposure of 40 days). We noticed that the absorption intensity was decreased with decreasing concentration, before gamma irradiation while the absorption spectrum peak shifted towards the short wavelength (blue shift). It was also found that the intensity of absorption spectrum increased and shifted the absorption spectrum peak towards the long wavelength (red

... Show More
View Publication Preview PDF
Crossref