Patients are very concerned about the lengthy nature of orthodontic treatment. It is necessary to find a non-invasive way to quicken physiologic tooth movement. This study's objective was to assess the effectiveness of low-intensity laser therapy in shortening the time and discomfort of orthodontic treatment. Experimental work: Using a split-mouth study to compare tooth movement with conventional treatment and laser-accelerated orthodontic tooth movement. A patient presenting with a class II division I malocclusion characterized by the misalignment of the upper and lower teeth as classified by Angle’s molar classification system was indicated to undergo fixed orthodontic appliance orthodontic treatment. The treatment plan involved bilateral extraction of the upper first premolar teeth on both sides and distalization of the anterior segment to close the created space. For an experimental investigation, a patient was chosen at random and given right-side radiation using a dual diode laser (810,980 nm wavelength, 100 mW output power). Results: The tooth movement was measured over a period of 15 weeks; the first three orthodontic activations on the study side included scheduled laser treatment (the first month, laser-assisted treatment on days (0,3,7, and 14), the following two months, on days (0 and 14) from the day of orthodontic activation, and another 3 months of follow-up only); it was observed that orthodontic tooth movement was significantly higher in the study side than in the control side, as measured clinically using a digital vernier. We also noticed a considerable decrease in pain levels following a visual analog test. Conclusion: LLLT might clinically considerably speed orthodontic tooth movement and greatly lessen discomfort using the parameter settings employed in this investigation.
A numerical investigation has been performed to examine the effect of fluorine concentration on the chain reaction mechanisms and parameters of hydrogen fluoride (HF) chemical laser. The practical difficulties associated with this type of lasers impose that an alternative route might be quite useful. Thus, particular attention was paid to develop a computer program to investigate various processes. The results of this computer simulation program proved their credibility when compared with the little published data. This computer program is called Reaction Rate Simulation Model (RRSM). An entirely new approach to emulate the reaction mechanisms has been followed. The effectiveness of reaction rates in the processes of HF lase
... Show MoreDespite the importance of sustainable development and its dimensions in developing performance and supporting competitive advantage in economic units, there is a gap and lack of coordination between Combined Assurance providers (management, internal audit, external audit) to report on sustainable development, and the research aims to propose a model for the Combined Assurance report to achieve development sustainable development in the Iraqi economic units, especially the Baghdad Municipality, enables assurance providers to coordinate efforts that lead to the achievement of Combined Assurance, The research found the proposed model for the Combined Assurance report in achieving sustainable development in the Iraqi economic units, es
... Show MoreBackground:In this study,TiO2 layer was thermally grown as a diffusion barrier on CP Ti substrate prior to electrophoretic deposition of HA coatings, to improve the coating’s compatibility also macro and micro pores in nano Hydroxyapatite dual coatings were created and their effect on the bond strength between the bone and implant was evaluated. Materials and methods: Electrophoretic Deposition technique (EPD) was used to obtain coatings for each one of four types of Hydroxyapatite(HA)on CP Ti screws (micro HA, nano HA, dual nano HA with micro pores, dual nano HA with macro pores) where carbon particles used as fugitive material to be removed by thermal treatment to create porosity.For examination of the changes occurred on the subs
... Show MoreDiode laser technology is well established for biomedicine applications which demand high-power pulse-wave. They are extensively utilized from medical imaging and testing to surgical therapies and the latest aesthetic processes. For medical therapeutic practices, diode lasers have become the ideal laser source for this particular purpose. In the last previous years, semiconductor laser technology has evolved to produce high-repetitions rate near-infrared pulsed lasers diodes that are dependable, low-cost, portable, and small-weight, about few grams. In this paper, we review the recent development and demonstration of diode laser devices for biomedical applications recorded in the latest years taking into account the power, wavelength, and p
... Show MoreOptical fiber technology is without a doubt one of the most significant phases of the communications revolution and is crucial to our daily lives. Using the free version (2022) of RP Fiber Calculator, the modal properties for optical fibers with core radii (1.5−7.5) μm, core index (1.44−1.48) and cladding index (1.43−1.47) have been determined at a wavelength of 1000 nm. When the fiber core’s radius is larger than its operating wavelength, multimode fibers can be created. The result is a single-mode fiber in all other cases. All of the calculated properties, it has been shown, increase with increasing core radius. The modes’ intensity profiles were displayed.
In this work, we apply the notion of a filter of a KU-Algebra and investigate several properties. The paper defined some filters such as strong filter, n-fold filter and P-filter and discussed a few theorems and examples.
Background: The purpose of the current study was to evaluate the efficacy of a new orthodontic bonding system (Beauty Ortho Bond) involving the shear bond strength in dry and wet environments, and adhesion remnant index (ARI) scores evaluation in regard to other bonding systems (Heliosit and Resilience Orthodontic Adhesives). Materials and methods: Sixty defect free extracted premolars were randomly divided into six groups of 10 teeth each, mounted in acrylic resin, three groups for a dry environment and three for a wet one. Shear bond strength test was performed with a cross head speed of 0.5 mm/min, while surfaces of enamel and bracket-adhesive-enamel surfaces were examined with stereomicroscope For ARI scores evaluation. Data were analyz
... Show MoreStatement of the Problem. The use of orthodontic fixed appliances may adversely affect oral health leading to demineralizing lesions and the development of gingival problems. Aims of the Study. The study aimed to coat orthodontic archwires with chlorhexidine hexametaphosphate nanoparticles (CHX-HMP NPs) and to evaluate the elusion of CHX from CHX-HMP NPs. Materials and Methods. A solution of CHX-HMP nanoparticles with an overall concentration of 5 mM for both CHX and HMP was prepared, characterized (using atomic force microscope and Fourier transformation infrared spectroscopy), and used to coat orthodontic stainless steel (SSW) and NiTi archwires (NiTiW). The coated segments were characterized (using scanning electron microscopy
... Show MoreThe present research aims to identify and define the basic dimensions of the information management strategy and the administrative creativity in the Faculty of Management and Economics / the University of Kirkuk, as well as the role played by the dimensions of the information technology management strategy in achieving the administrative innovation in the college and the research problem was formulated in several questions. The research problem was formulated in several questions centered on the correlation between the research variables, and the research was based on a major hypothesis and five sub-hypotheses emerged from which it was subjected to several tests to ensure its validity. The researcher used the descriptive-analyti
... Show More