Preferred Language
Articles
/
ijl-380
PDF The effect of nanoelectrodes number and length on enhancing the THz photomixer performance
...Show More Authors

Abstract: Despite the distinct features of the continuous wave (CW) Terahertz (THz) emitter using photomixing technique, it suffers from the relatively low radiation output power. Therefore, one of effective ways to improve the photomixer emitter performance was using nanodimensions electrodes inside the optical active region of the device. Due to the nanodimension sizes and good electrical conductivity of silver nanowires (Ag-NWs), they have been exploited as THz emitter electrodes. The excited surface plasmon polariton waves (SPPs) on the surface of nanowire enhances the incident excitation signal. Therefore, the photomixer based Ag-NW compared to conventional one significantly exhibits higher THz output signal. In this work, the effect of Ag-NWs dimensions and number on the incident optical field is investigated by utilizing the Computer Simulation Technology (CST) Studio Suite. The simulation results show that increasing Ag-NWs length to SPP propagation length ratio plays a significant role on the incident field increment due to its effect on reducing the SPP propagation losses. The increment of Ag-NWs number and length in the nanoelectrodes based photomixer can contribute to increase the electric field in the active region by 1.5 times at the longer excitation wavelength (850 nm). As a result of this increment, the THz output power and the conversion efficiency are expected to be enhanced by a factor of five

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 19 2020
Journal Name
Indonesian Journal Of Chemistry
Determination of Eugenol in Personal-Care Products by Dispersive Liquid-Liquid Microextraction Followed by Spectrophotometry Using <i>p</i>-Amino-<i>N,N</i>-dimethylaniline as a Derivatizing Agent
...Show More Authors

Two simple methods for the determination of eugenol were developed. The first depends on the oxidative coupling of eugenol with p-amino-N,N-dimethylaniline (PADA) in the presence of K3[Fe(CN)6]. A linear regression calibration plot for eugenol was constructed at 600 nm, within a concentration range of 0.25-2.50 μg.mL–1 and a correlation coefficient (r) value of 0.9988. The limits of detection (LOD) and quantitation (LOQ) were 0.086 and 0.284 μg.mL–1, respectively. The second method is based on the dispersive liquid-liquid microextraction of the derivatized oxidative coupling product of eugenol with PADA. Under the optimized extraction procedure, the extracted colored product was determined spectrophotometrically at 618 nm. A l

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref