Preferred Language
Articles
/
ijl-37
Bartholin Gland Cyst Treatment using Carbon Dioxide Laser (10600 nm)
...Show More Authors

The Bartholin gland cyst is a condition that occurs in approximately 2% of women, most of whom are of reproductive age. Although benign pathology, it is associated with significant patient discomfort. This disorder is caused by the obstruction and consequent dilation of the cyst duct. Definitive treatment involves the surgical removal of the entire cyst. Other alternative treatments include Marsupialization, Word catheter, and the use of CO2 laser. CO2 laser can be used either to vaporize or to excise the Bartholin gland cyst. The Objectives: The purpose of the study was to evaluate the efficacy and safety of (10600nm) CO2 laser in the treatment of Bartholin gland cyst. Patients, Materials & Methods: This study was done in laser medicine research clinics from July 2015 to the end of December 2015; 10 female patients whose ages ranged from 25 years to 50 years and who have Bartholin cyst. The details of the procedure were explained verbally to the patients and consent was written. Patients were examined and evaluated clinically and prepared for surgery. A CO2 continuous wave 1-40W laser emitted at 10600 nm. The laser is delivered via an articulated arm and laser is used to incise the cyst wall and vaporize the inner surface of the cyst. Results: The preliminary clinical findings included sufficient hemostasis, vaporization properties and precise incision margin with all of the surgical procedure. The postoperative advantages, i.e., lack of pain, bleeding, infection, good wound healing and overall satisfaction were observed. Conclusion: The clinical application of the CO2 (10600 nm) laser in surgical procedures can be considered practical, effective, easy to use and offers a safe, acceptable, and impressive alternative for conventional techniques of surgical treatment Bartholin gland cyst.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 01 2015
Journal Name
Photomedicine And Laser Surgery
Evaluation of Temperature Elevation During Root Canal Treatment with Dual Wavelength Laser: 2780 nm Er,Cr:YSGG and 940 nm Diode
...Show More Authors

Scopus (33)
Scopus
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
In vitro Investigation the Antifungal and 940 nm Diode Laser Effects on Inhibition of Candida Albicans Isolated from Oral Cavity
...Show More Authors

Background: Candida albicans is a prevalent commensal that can cause severe health problems in humans. One such condition that frequently returns after treatment is oral candidiasis. Aim: the goal of this research is to evaluate the efficiency of 940 nm as a fungicidal on the growth of Candida albicans in vitro. Material and Methods: In vitro samples (fungal swabs) were taken from the oral cavity of 75 patients suffering from oral thrush. Following the process of isolating and identifying Albicans. The samples are divided into four groups:(Group 1): Suspension of C. albicans was put in a solution of saline as a control group. (Group 2): Suspension of C. albicans that had been treated wit

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 12 2017
Journal Name
Iraqi Journal Of Laser
A Comparative Evaluation of Post-Operative Pain and Function after Gingival Depigmentation Using 940 Nm Diode Laser And Conventional Bur Method: 6 Months Study
...Show More Authors

The aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 10 2009
Journal Name
Iraqi Journal Of Laser
Bactericidal effect of Q-switched Nd:YAG laser (1064 nm ) on Streptococcus mutans from carious teeth ,in vitro study
...Show More Authors

Dental caries (tooth decay) is one of the most prevalent infectious disease and although of multifactorial origin, Streptococcus mutans is considered the principal pathogen in its development (i.e. bacterial processes damage hard tooth structure (enamel, dentine and cementum), producing dental cavities (holes in the teeth). The bactericidal properties of the Nd:YAG laser has been researched analyzing its use in caries prevention and bacterial reduction. One hundred twenty five samples were collected from carious teeth and isolated bacteria were diagnosed using microscopic examination, culture, biochemical tests, and Api 20 strep system. The results of this study showed that a noticeable decrease in the viability of Streptococcus mutans w

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2006
Journal Name
Journal Of Cosmetic And Laser Therapy
Use of the pulsed infrared diode laser (904 nm) in the treatment of alopecia areata
...Show More Authors

View Publication
Scopus (49)
Crossref (55)
Scopus Crossref
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Effectiveness of 980nm diode Laser in reduction the diameters of exposed dentinal tubules for hypersensitive tooth
...Show More Authors

Abstracts:

Background: The oral cavity is a complex environment, both structurally and functionally, the hard and soft tissues are in close a proximity. Oral tissues subjected to wear throughout the life, that threatened the vitality of the pulp or increase the sensitivity of dentinal tubules. One of the common dental problems is loss of enamel or cementum, which stimulate the nerve ending in or near the pulp and manifested as pain sensation. Aim of the study: This study had done to evaluate the effects of 980nm diode Laser in diameters reduction of exposed dentinal tubules analyze the results and morphological changes of irradiated dentine surface by FE-SEM (field emission scann

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2010
Journal Name
Al-khwarizmi Engineering Journal
355nm Wavelength Generation of Nd:YAG Laser Using Olive Oil
...Show More Authors

 This project introduces a prospective material for photonic laser applications. The material is olive oil which is classified as organic compound, having a good nonlinear optical properties candidate to be used in photonic applications. A high purity sample of olive oil has been used. The theoretical calculation to generate third harmonic wave using olive oil has been determine using MATLAB program. THG (λ=355nm) intensity has been determined at two cases of sample thicknesses 1mm and 10mm. The minimum threshold incident intensity to obtain THG intensity are equal Iω=7530 mW/cm2 at L=1mm and Iω= 6220 mW/cm2 at L=10mm. The possibility of generation of third harmonic in olive oil inside

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
Studying the Photodegradation of Congo Red Dye from Aqueous Solutions Using Bimetallic Au–Pd/TiO2 Photocatalyst
...Show More Authors

In this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest deg

... Show More
View Publication Preview PDF
Scopus (15)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Tue Dec 13 2005
Journal Name
Iraqi Journal Of Laser
Stimulation of Phagocytic Activity of Human Polymorphonuclear Leukocytes in Vitro Using 10 mW He-Ne Laser.
...Show More Authors

Stimulative effect of 10 mW He-Ne laser on the phagocytic activity of human polymorphonuclear leukocytes( PMNs) has been studied in vitro. Normal polymorphonuclear leucocytes were isolated from the human peripheral blood. A mixture of 0.25 ml of Hanks solution, 0.25 ml of serum, 0.25 ml of Candida albicans suspension and 0.25 ml of PMNs suspension was prepared. The samples of mixture of PMNs and Candida were subdivided in 1 ml ependrof tubes and irradiated to He-Ne laser for 1, 3, 5, 10 and 20 min. The diameter of the irradiated area was 0.8 cm. For calculation of Phagocytic index before and after irradiation, the samples were incubated (37°C) at 5, 15, 30, 60 min. The slides of samples were prepared and stained using Giemsa stain. The

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 13 2005
Journal Name
Iraqi Journal Of Laser
Clinical Observation and Performance of High Power Diode Laser in the Treatment of Oral Lesions
...Show More Authors

In this work, oral lesions belong to 17 patients, 7 males and 10 females. Their ages range between 15 and 45 years. Follow up was conducted after one day, 7 days, 14 days, one month, and finally 3 months postoperatively. The study lasted for 1.5 year. Surgical diode laser with wavelength of 810 ± 20 nm, with two power levels of 10 and 15 W were used in contact and in non-contact mode via optical fiber. The postoperative outcome revealed; greater haemostatic capability, dry, sealed wound and noticeable lack in pain sensation

View Publication Preview PDF