Preferred Language
Articles
/
ijl-370
PDF Lab-On-a-Chip an integrated microfluidic device sensitive low-Cost, and Rapid with a syringe pump for Analysis of Ibuprofen
...Show More Authors

Abstract: Microfluidic devices present unique advantages for the development of efficient drug assay and screening. The microfluidic platforms might offer a more rapid and cost-effective alternative. Fluids are confined in devices that have a significant dimension on the micrometer scale. Due to this extreme confinement, the volumes used for drug assays are tiny (milliliters to femtoliters).

 In this research, a microfluidic chip consists of micro-channels carved on substrate materials built by using Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters have influence on the width, depth, roughness of the chip. In order to have regular channel surface, and low roughness  the laser power (60 W),  with scanning speed (250 m/s)  for allows us to obtain microchannels with a minimum diameter of width  (450 µm),  depth of the channels was 89.4 µm and( Arithmetic Average Roughness Ra = 2.3), (Relative roughness, Ɛ = 5%) surface roughness with high accuracy and good surface quality.  

The functionalized multiwalled carbon nanotubes (F-MWCNTs) was used to enhance the drug signal inorder to detect very tiny Ibuprofen concentration. In this work, laser microfluidic sensor have high accuracy in Ibuprofen detection compared to the traditional method(UV-VIS) spectrophotometer with LOD equal to 0.25  nM, 1000µM respectively.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 17 2022
Journal Name
Iraqi Journal Of Laser
PDF Biosensing technique for detection of H.pylori bacteria: Israa M.L. SaQari*, Layla M.H. Al-ameri
...Show More Authors

Abstract :H.pylori is an important cause of gastric duodenal disease, including gastric ulcers, Mucosa-associated lymphoid tissue (MALT), and gastric carcinoma. biosensors are becoming the most extensively studied discipline because the easy, rapid, low-cost, highly sensitive, and highly selective biosensors contribute to advances in next-generation medicines such as individualized medicine and ultrasensitive point-of-care detection of markers for diseases.  Five of ten patients diagnosed with H.pylori ranging in age from 15–85 participated in this research. who [gastritis, duodenitis, duodenal ulcer (DU), and peptic ulcer (PU)] Suspected H.pylori colonies w

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 01 2023
Journal Name
Industrial Laboratory. Materials Diagnostics
OPTIMIZATION OF PLASMA-ASSISTED DESORPTION/IONIZATIONMASS SPECTROMETRY FOR ANALYSIS OF IBUPROFEN
...Show More Authors

In medical practice, nonsteroidal anti-inflammatory drugs (NSAIDs) are often used to treat osteoarthritis and rheumatoid arthritis. Ibuprofen is a well-known NSAID, analgesic, and antipyretic medication. This chemical is an active ingredient of several oral medications that are offered in tablet, gel pellet, and syrup forms and has higher efficacy, tolerance, and side effect rates than other compounds, including pyrazolone derivatives. We present a unique plasma-assisted desorption/ionization mass spectrometry (PADI-MS) approach for improving pharmaceutically important solids using an ibuprofen tablet as a model solid sample. The goal of the study is to create an innovative mass spectrometric method that could be used for quick and accur

... Show More
Preview PDF
Publication Date
Tue May 11 2021
Journal Name
Photonics And Nanostructures - Fundamentals And Applications
The spontaneous emission performance of a quantum emitter coupled to a hybrid plasmonic waveguide with specified output polarization for on-chip plasmonic single-photon source
...Show More Authors

Nowadays, most of the on-chip plasmonic single-photon sources emit an unpolarized stream of single photons that demand a subsequent polarizer stage in a practical quantum cryptography system. In this paper, we numerically demonstrated the coupling of the light emitted from a quantum emitter (QE) at 700 nm wavelength to the propagation mode supported by an on-chip hybrid plasmonic waveguide (HPW) polarization rotator. Our results proved that the light emitted is linearly polarized at 0º, 45º/−45º, and 90º with propagation lengths of 5 μm, 3.3 μm, and 3.9 μm, respectively. Moreover, high power-conversion efficiency was obtained from an applied transverse magnetic (TM) mode (0º-polarization) to a transverse electric (TE) (90º-polari

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Jul 01 2021
The spontaneous emission performance of a quantum emitter coupled to a hybrid plasmonic waveguide with specified output polarization for on-chip plasmonic single-photon source
...Show More Authors

Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Journal Of Optical Technology
Random signal generation and synchronization in lab-scale measurement device independent–quantum key distribution systems
...Show More Authors

In this paper, a random transistor-transistor logic signal generator and a synchronization circuit are designed and implemented in lab-scale measurement device independent–quantum key distribution systems. The random operation of the weak coherent sources and the system’s synchronization signals were tested by a time to digital convertor.

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Spectrophotometrically Analysis of PMMA as a low – Doses Dosimeter
...Show More Authors

Polymethylmethacrylate film (PMMA) of thickness 75 μm was evaluated Spectrophotometrically for using it as a low-doses gamma radiation dosimeter. The doses were examined in the range 0.1 mrad-10 krad. Within an absorption band of 200-400 nm, the irradiated films showed an increase in the absorption intensity with increasing the absorbed doses. Calibration curves for the changes in the absorption differences were obtained at 218, 301, and 343 nm. At 218 nm the response for the absorbed doses is a linear in the range 10 mrad- 10 krad. Hence it is recommended to be adopted as an environmental low doses dosimeter

View Publication Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
مجلة جامعة االنبار للعلوم البدنية والرياضية
The effects of Pilates exercises while using the ladder barrel device on fitness and coordinatedin performance for motor formations in artistic gymnastics for students
...Show More Authors

The aim of the research was to prepare Pilates exercises using the barrel ladder apparatus and to identify the effect of Pilates exercises on agility, coordination, and motor sequences of third-year female students in artistic gymnastics. The researcher adopted the experimental method to achieve the objectives of the study and to verify its hypotheses, as it is suitable for the nature and problem of the research. In selecting the research population, the researcher carefully chose the sample using a purposive method, clarifying its elements and constituent units. The research population consisted of third-year female students at the College of Physical Education and Sports Sciences for Women / University of Baghdad, with a total of 20 stud

... Show More
Preview PDF
Publication Date
Fri May 15 2009
Journal Name
Journal Of Planner And Development
Preservation of heritage markets within an integrated framework to preserve the urban heritage in the historical centers of cities (selected models and experiments)
...Show More Authors

This research discusses the rehabilitation of heritage markets in the historical centers of Islamic Arab cities and their use in the field of cultural tourism as one of the most important tourist attractions and the subsequent revival of the national economy in addition to preserving the urban heritage as these markets part of the historical centers of cities. The research also discusses the preservation of the continuity of heritage markets as a product of cultural heritage value within an integrated framework to preserve the urban heritage in the historic centers of cities. The study then reviews a number of experiences of Arab and Islamic countries in the field of preserving and rehabilitating heritage markets, which qualify them to b

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
A Hyperbolic Potential Field Model for Designing an Einzel Lens of Low Aberrations
...Show More Authors

An analytical model in the form of a hyperbolic function has been suggested for the axial potential distribution of an electrostatic einzel lens. With the aid of this hyperbolic model the relative optical parameters have been computed and investigated in detail as a function of the electrodes voltage ratio for various trajectories of an accelerated charged-particles beam. The electrodes voltage ratio covered a wide range where the lens may be operated at accelerating and decelerating modes. The results have shown that the proposed hyperbolic field has the advantages of producing low aberrations under various magnification conditions and operational modes. The electrodes profile and their three-dimensional diagram have been determined whi

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Performance Study of Polarization Beam Splitters Based on Horizontal Slot Waveguide Operating at 700nm Wavelength
...Show More Authors

Abstract: Polarization beam splitter (PBS) integrated waveguides are the key components in the receiver of quantum key distribution (QKD) systems. Their function is to analyze the polarization of polarized light and separate the transverse-electric (TE) and transverse-magnetic (TM) polarizations into different waveguides. In this paper, a performance study of polarization beam splitters based on horizontal slot waveguide has been investigated for a wavelength of . PBS based on horizontal slot waveguide structure shows a polarization extinction ratio for quasi-TE and quasi-TM modes larger than  with insertion loss below  and a bandwidth of . Also, the fabrication tolerance of the structure is analyzed.<

... Show More
View Publication Preview PDF