The effect of 410nm with 100 mW output power and one centimetre spot size (0.128 W/cm2 power density) Diode laser irradiation at different exposure times on the growth of Gram-negative Pseudomonas aeruginosa and Gram-positive Staphylococcus aureus was evaluated. Seventy swap samples were collected from burn and infected wounds of 35 patients admitted to the burn-wound unit in Al-Yarmouk Teaching Hospital in Baghdad during the period from December 2014 to February 2015. These bacteria were isolated and identified depending on their growth on selective media, cultural characteristics, Gram stain morphology and biochemical tests and finally were confirmed by Vitek 2 compact system test .Susceptibility of bacterial isolates to 15antibiotics was tested using the disk diffusion method. Bacterial standard suspension of 108 cell/ml was prepared for P. aeruginosa and S. aureus. Dilutions of 10-6 cell/ml for P. aeruginosa and 10-5 cell/ml for S. aureus were selected. Ten replicates were used for each experimental group. Following irradiation, CFU/ml was calculated, and antibiotic susceptibility test was performed for the most resistant isolate for each bacterial species. From the results, it was found that out of the 70 samples, 17 isolates (24.3%) were P. aeruginosa and 9 isolates (12.9%) were S. aureus. Antibiotic susceptibility test showed that all isolates of P. aeruginosa and S. aureus were multidrug resistant. It was shown that laser irradiation did not affect the susceptibility of P. aeruginosa isolate to all antibiotics tested. However, a slight increase in the susceptibility of S. aureus isolate to Ampicillin/Cloxacillin, Tetracycline and Vancomycin was observed. Laser Irradiation experiments showed that the number of CFU/ml of P. aeruginosa and S. aureus was significantly reduced with increasing exposure times, reaching a100% bacterial mortality at 13 minutes for S. aureus and 19 minutes for P. aeruginosa. In conclusion, the blue laser irradiation seems to have more bactericidal effect on Gram-positive bacteria (S. aureus) than on Gram-negative (P. aeruginosa).
Pseudomonas aeruginosa, a ubiquitous environmental organism, is a difficult-to-treat opportunistic pathogen due to its broad-spectrum antibiotic resistance and its ability to form biofilms. In this study, we investigate the link between resistance to a clinically important antibiotic, imipenem, and biofilm formation. First, we observed that the laboratory strain P. aeruginosa PAO1 carrying a mutation in the oprD gene, which confers resistance to imipenem, showed a modest reduction in biofilm formation.We also observed an inverse relationship between imipenem resistance and biofilm formation for imipenem-resistant strains selected in vitro, as well as for clinical isolates.We identified two clinical isolates of P. aeruginosa from the sputum
... Show MoreIn the present work, heterojunction diode detectors will be prepared using germanium wafers as a substrate material and 200 nm tin sulfide thickness will be evaporated by using thermal evaporation method as thin film on the substrate. Nd:YAG laser (λ=532 nm) with different energy densities (5.66 J/cm2 and 11.32 J/cm2) is used to diffuse the SnS inside the surface of the germanium samples with 10 laser shots in different environments (vacuum and distilled water). I-V characteristics in the dark illumination, C-V characteristics, transmission measurements, spectral responsivity and quantum efficiency were investigated at 300K. The C-V measurements have shown that the heterojunction were of abrupt type and the maximum value of build-in pot
... Show MoreIn the present work usedNd:YAG laser systems of different output characteristic were employed to study the drilling process of material used in scientific and industrial fields. This material include Manganese hard steel. Our study went into the affecting parameters in drilling of Manganese hard steel by laser. Drilling process is achieved through material absorption of part of the incident laser beam. It is the resultant of interfering both, laser beam and material properties and the focusing conditions of the beam. The results as shown that the increase in the laser pulse energy over the used level has raised the hole diameter, depth and increased the hole taper. In addition to that a hole taper was affected by the laser energy, the fo
... Show MoreThree isolates of P. aeruginosa were isolated from burnt patients. The ability of these isolates for adhesion and formation of slime layer were tested, the result showed that all isolates were able to adherence on the smooth surface. The sensitivity of P. aeruginosa isolates for antibiotics were tested , all isolates were sensitive to Gentamycin, Piperacillin and Amikacin Ciprofloxacin, and resist to Tetracyclin, Amoxicillin, Cephalexine , Ceftriaxone. Ciprofloxacin and Amikacin were found effective against P. aeruginosa isolates with MIC values of 3.8 μg/ ml for Ciprofloxacin and 0.244 μg/ ml for Amikacin The antibacterial effect of Different concentrations of Aloe
... Show MoreBackground: L. sativum, are traditionally used for the treatment of various diseases and thought to have medicinal value. Isolates from many part of the world is now multidrug resistant. Therefore, there is an urgent need to look for and test an alternative herbal drug.
Objective: The present study aimed to evaluate the antibacterial activity of L. Sativum seed extract against multi drug resistant (MDR) and sensitive Pseudomonas aeruginosa clinical isolates.
Subjects and Methods: An ethanolic and aqueous stock extracts were prepared from L. sativum seed plant then serial dilutions were prepared and the obtained concentrations (50, 25, 12.5 and 6.2 mg/ml) were tested against 30 multidrug-resistan
... Show MoreThe bacterial isolates were obtained from Al-Kindi Hospital were diagnosed by the Vitek-2 system and re confirm by 16srRNA gene as S. aurous, the results were shown 20 isolates (66.7%) out of 30 isolates were positive to protease production. All bacterial isolates (100%) were sensitive to Gentamicin and Levofloxacin. but resistant (100%) to aztreonam. The best temperature for enzyme production from bacteria was 37 °C, and the best pH for enzyme production was 7. Partial purification of the bacterial enzyme (protease) was carried out using short steps included ammonium sulfate 65% saturation, ion exchange using DEAE- cellulose column and then applied on gel filtration chromatography using Sephadex G-200 column. The enzymatic activit
... Show MoreThe results of the present study showed that twenty-five samples were collected for the age group 35–40 years and four samples for the age group 65–70 years for both genders. The results showed that 48 (48%) of the samples were obtained from the hands, 16 (16%) from the legs, 12 (12%) from the abdominal area, and 10 (10%) from the chest area. The four (4%) samples were obtained from burns in the back and thighs area. The samples taken according to the cause of burns were 40 (40%) due to hot water, hot liquids, or hot steam, followed by 18 (18%) due to the use of hot tools, 15 (15%) due to fires, 12 (12%) due to electric currents, 10 (10%) due to chemicals such as strong acids, alkaline lye, paint thinner, or gasoline, and 5 (5%) due
... Show MoreBacteria form complex and highly elaborate surface adherent communities known as biofilms.Biofilm have been shown to be associated with several human diseases ,and to colonize a wide variety of medical devices . The current study focuses on contribution of extracted genomic DNA in biofilm formation by P. aeruginosa and K. pneumoniae isolates .The percentages of Pseudomonas aeruginosa recovery from drinking water in this study were 10%(20 positive P. aeruginosa samples ) and K. pneumonia., 7%(14 positive K. pneumonia samples).The results showed that all P.aeruginosa and K. pneumoniae isolates (100%) were slime producer but in different degrees by forming of black
... Show MoreAim: surface modification of titanium using fiber laser 1064 nm to enhance the bond strength to resin cement. Material and Methods: thirty titanium discs of 0.6 cm x 0.3 cm (diameter and thickness respectively) were categorized after preparation into three groups (n=10) as follows: control group with no surface treatment and two test groups were treated with fiber laser after estimation the appropriate parameters in the pilot study which are 81 ns pulse duration, 30,000 Hz frequency, 50 µm spot size and 10,000 mm/s scanning speed and different average power values (10 W and 20 W) depending on the tested group. Titanium discs surface characterization was performed by scanning electron microscope (SEM), a
... Show More