Preferred Language
Articles
/
ijl-336
PDF Evaluation of 940 nm Diode Laser in Esthetic Crown Lengthening
...Show More Authors

Abstract Background: Crown lengthening is a surgical procedure that apically positions the gingival edge and/or removes supporting bone in order to increase the amount of supra gingival tooth structure for restorative or cosmetic purposes.

The objective of the study: The purpose of this study was to evaluate the efficacy of the 940nm diode laser in esthetic crown lengthening surgery through clinical observations, patient questionnaires, clinical photographs, and gingival healing following gingival operations. Material and methods: In this randomized clinical trial, 16 patients (11 females and 5 males) had their crowns surgically lengthened using a diode laser (940 nm) in continuous wave (CW) mode with 1 watt energy settings. A visual analogue scale is used on the first, third, seventh, and twenty-first days following surgery to record pain, swelling, bleeding, functional interference, tooth sensitivity, and success from an aesthetic standpoint, as well as overall patient satisfaction based on patient opinion and clinical photographs. Results: In the present study, we noticed that the scale of pain, bleeding, oedema, function interferance, and tooth sensitization significantly decreased gradually during the first two visits. The measured parameters completely disappeared after one week in most cases, as well as increase patient satisfaction and aesthetic achievement. The patients were recalled three weeks later, the wounds had totally healed, and the patient were not complaining of any pain. Conclusion: Crown lengthening requires optimal gingival margin design. This involves precise shaping of delicate tissues, which is difficult with the scalpel. While Lasers give improved gingival sculpting control and can be used for aesthetic crown lengthening. The laser surgery has many advantages, including excellent hemostasis with little or no bleeding, being less invasive and sterile wound cut, causing less pain and suffering during and after surgery, and enhancing patient satisfaction since the operation is short and, in most circumstances, relatively painless. Also, in laser surgery, there is less functional interruption and enhanced patient satisfaction since a periodontal pack is not needed to cover the surgery site. The healing is faster and more aesthetic when using laser surgery procedure.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Laser Improves Biogas Production by Anaerobic Digestion of Cow Dung
...Show More Authors

This study investigates the digestion of cow dung (CD) for biogas production at laboratory scales. The study was carried out through anaerobic fermentation using cow dung as substrate. The digester was operated at ambient temperatures of 39.5 °C for a period of 10 days. The effect of iron powder in controlling the production of hydrogen sulfide (H2S) has been tested. The optimum concentration of iron powder was 4g/L with the highest biogas production. A Q – swatch Nd:YAG laser has been used to mix and homogenize the components of one of the six digesters and accelerate digestion. At the end of digestion, all digestions effluent was subjected to 5 laser pulses with 250mJ/pules to dispose waste biomass.

View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Dec 02 2017
Journal Name
Al-khwarizmi Engineering Journal
Speech Signal Compression Using Wavelet And Linear Predictive Coding
...Show More Authors

A new algorithm is proposed to compress speech signals using wavelet transform and linear predictive coding. Signal compression based on the concept of selecting a small number of approximation coefficients after they are compressed by the wavelet decomposition (Haar and db4) at a suitable chosen level and ignored details coefficients, and then approximation coefficients are windowed by a rectangular window and fed to the linear predictor. Levinson Durbin algorithm is used to compute LP coefficients, reflection coefficients and predictor error. The compress files contain LP coefficients and previous sample. These files are very small in size compared to the size of the original signals. Compression ratio is calculated from the size of th

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Chemical Sensor Based on a Hollow-Core Photonic Crystal Fiber
...Show More Authors

In this work a chemical sensor was built by using Plane Wave Expansion (PWE) modeling technique by filling the core of 1550 hollow core photonic crystal fiber with chloroform that has different concentrations after being diluted with distilled water. The minimum photonic bandgap width is.0003 and .0005 rad/sec with 19 and 7 cells respectively and a concentration of chloroform that filled these two fibers is 75%.

View Publication Preview PDF
Publication Date
Tue Nov 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Performance evaluation of policies and programs accordance with guide prepared by a dutch court of audit and the board of supreme audit (case study in wasit state company for textile industries)
...Show More Authors

Abstract\

preparation process of performance evaluation in organizations is of extreme importance, and under development in organizations and the opening of markets and technological developments in the industry and heightened competition among industrial organizations imposed systems are built for performance give a clear picture about performance and competition,  And centered research problem in answering the following questions: Is performance evaluation system is available in Wasit State Company for Textile Industries(Research sample ), This research aims to assess the performance of policies and programs in the company, according to guide performance evaluation of programs and policies prepared by the Dutch Cou

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Estimation of electron temperature for SiO2 plasma induced by laser
...Show More Authors

In this work; Silicon dioxide (SiO2) were fabricated by pulsed
laser ablation (PLA). The electron temperature was calculated by
reading the data of I-V curve of Langmuir probe which was
employed as a diagnostic technique for measuring plasma properties.
Pulsed Nd:YA Glaser was used for measuring the electron
temperature of SiO2 plasma plume under vacuum environment with
varying both pressure and axial distance from the target surface. The
electron temperature has been measured experimentally and the
effects of each of pressure and Langmuir probe distance from the
target were studied. An inverse relationship between electron
temperature and both pressure and axial distance was observed.

View Publication Preview PDF
Crossref
Publication Date
Mon Dec 16 2024
Journal Name
Light & Engineering
The Design and Experimental Realization of a Laser-Based Heating System Using Recycled Laser Module
...Show More Authors

Laser is a powerful device that has a wide range of applications in fields ranging from materials science and manufacturing to medicine and fibre optic communications. One remarkable

View Publication
Publication Date
Wed Jan 01 2020
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of Nurses knowledge toward prevention of Complications related Valvular Replacement Surgery at Surgical Department in AL-Nasiriyah Heart Center
...Show More Authors

Objectives: The study aims to assess  the nurses knowledge toward prevention of complications related to valvular  replacement surgery and to find out the relationship between nurses knowledge and their demographic and occupational characteristic's Which as (Age, gender, level of education ,years of experience in Surgical Department , and training sessions)

 

Methodology: A descriptive design  (a cross-sectional study ) was carried out from December 2017 to May 2018 in order to assess nurses' knowledge of preventing complications Valvular Replacement Surgery at Surgical Department in  Nasiriyah Heart Center on a purposive (non-probability) sample

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 02 2009
Journal Name
Journal Of The Faculty Of Medicine Baghdad
0.1 Second versus 0.2 Second pulse duration of Frequency Doubled Nd: YAG Laser in treatment of Clinically Significant Diabetic Maculopathy.
...Show More Authors

Background: clinically significant macular edema (CSME) is the commonest cause of visual loss in patients with diabetes mellitus and laser focal photocoagulation is the golden standard for treating it. Patients and Methods: A frequency doubled Nd: YAG laser was used to treat all eyes included in this study with diabetic maculopathy. Thirty eyes of three insulin dependent and twenty six non insulin dependent diabetic Iraqi patients were included. The study involved twenty six males, three females and followed for one year. Their ages were ranging between 36- 59 years, all of them from patients attending ophthalmic out-patient department in the medical city in the period between January 2005 and June 2006. Eyes divided in to two groups (fifte

... Show More
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
The role of spiral Computerized Tomography in diagnosis of stroke
...Show More Authors

Objective: The aim of this study is to determine the role of spiral Computerized Tomography in the diagnosis and
detection the types of stroke.
Methodology: One hundred sixty two patients (162) (99 males and 63 females) their ages ranging from (13 – 80)
year, all of them are suffering from stroke. They were collected randomly from spiral Computerized Tomography
unit in Baquba Teaching hospital during the period from November / 2010 to December / 2011 .All the patients
were examined clinically and then done spiral Computerized Tomography examination.
Results : The results of this study showed that the stroke effected different age groups and both sex but males is
more affected than the females .The results of spiral

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Night Vision monitor for IR laser spot size Identification
...Show More Authors

The aim of this research is to design and construct a
semiconductor laser range finder operating in the near infrared range
for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of wavelength
0.904 μm with a beam expander and the receiver; a silicon pin
detector biased to approve the fast response time with it's collecting
optics. The transmitters pulse width was 200ns at a threshold current
of 10 Ampere and maximum operating current of 38 Ampere. The
repetition rate was set at 660Hz and the maximum operating output
power was around 1 watt. The divergence of the beam was 0.268o
the efficiency of the laser was 0.03% at a duty cycle of 1.32x

... Show More
View Publication Preview PDF