Preferred Language
Articles
/
ijl-327
PDF Mechanical Properties of AISI 316L Stainless Steel Produced Via Selective Laser Melting
...Show More Authors

Abstract Additive manufacturing has been recently emerged as an adaptable production process that can fundamentally affect traditional manufacturing in the future. Due to its manufacturing strategy, selective laser melting (SLM) is suitable for complicated configurations. Investigating the potential effects of scanning speed and laser power on the porosity, corrosion resistance and hardness of AISI 316L stainless steel produced by SLM is the goal of this work. When compared to rolled stainless steel, the improvement is noticeable. To examine the microstructure of the samples, the optical microscopy (OM), scanning electron microscopy (SEM), and EDX have been utilized. Hardness and tensile strength were used to determine mechanical properties. The results indicated that the samples were completely dissolved, and the hardness was 285HV. Compared with the models produced by other parameters, the best 0.3% porosity was obtained using 100 W laser power, a hatching distance of 70 µm, a layer thickness of 30µm, and a scanning speed of 600 mm/sec. In addition, the volumetric energy density value for the best result was 79 J/mm3.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Bartholin Gland Cyst Treatment using Carbon Dioxide Laser (10600 nm)
...Show More Authors

The Bartholin gland cyst is a condition that occurs in approximately 2% of women, most of whom are of reproductive age. Although benign pathology, it is associated with significant patient discomfort. This disorder is caused by the obstruction and consequent dilation of the cyst duct. Definitive treatment involves the surgical removal of the entire cyst. Other alternative treatments include Marsupialization, Word catheter, and the use of CO2 laser. CO2 laser can be used either to vaporize or to excise the Bartholin gland cyst. The Objectives: The purpose of the study was to evaluate the efficacy and safety of (10600nm) CO2 laser in the treatment of Bartholin gland cyst. Patients, Materials & Methods: This study was done in laser medi

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Employment the Laser to Fabricate the Surface Plasmon Resonance Sensor
...Show More Authors

The Optical Fiber sensor based on the Surface Plasmon Resonance (SPR) technology has
been a successful performance sensing and presents high sensitivity. This thesis investigates the
performance of several structure of SPR sensor in field of refractive index and chemical
applications. A structure of Multi-Mode Fiber- Single Mode Fiber- Multi Mode Fiber (MMFSMF-MMF)

View Publication Preview PDF
Crossref
Publication Date
Wed Jun 11 2003
Journal Name
Iraqi Journal Of Laser
Microdrop Size Measurement in a Mixing Unit Using Laser Technique
...Show More Authors

One of the troublesome duties in chemical industrial units is determining the instantaneous drop size distribution, which is created between two immiscible liquids within such units. In this work a complete system for measuring instantaneous droplet size is constructed. It consists of laser detection system (1mW He-Ne laser), drop generation system (turbine mixer unit), and microphotography system. Two immiscible liquids, water and kerosene were mixed together with different low volume fractions (0.0025, 0.02) of kerosene (as a dispersed phase) in water (as a continuous phase). The experiments were carried out at different rotational speed (1180- 2090 r.p.m) of the turbine mixer. The Sauter mean diameter of the drops was determined by la

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
The Egyptian Journal Of Remote Sensing And Space Science
Evaluate 3D laser point clouds registration for cultural heritage documentation
...Show More Authors

View Publication
Scopus (44)
Crossref (15)
Scopus Crossref
Publication Date
Sun May 26 2019
Journal Name
Iraqi Journal Of Science
A Random Laser Production Using Fluorescein Dye Doped TiO2 Nanoparticles
...Show More Authors

A random laser has been produced using Fluorescein dye solution in water, with concentration of (8 10-5 M); doped with (0.001g) TiO2 Nanoparticles with the particle size of (15.7 nm). A blue diode laser of 450 nm wavelength has been used as an optical pumping source. The wavelength of the random laser was 523 nm and the intensity was 5.44 mW

View Publication Preview PDF
Scopus (4)
Crossref (5)
Scopus Crossref
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
PHOTO DYNAMIC THERAPY (PDT) WITH BIOLOGICAL TISSUES USING ND:GLASS LASER
...Show More Authors

A Photo Dynamic Therapy (PDT) is a technique which is used with Laser to treat many of cancer
tissues. This paper deals with the relatively new therapeutic technique (PDT) with pulsed Nd:glass Laser
which was applied to human soft tissues (Ovary and Kidney tissues), and to the hard tissues (freshly
extracted human teeth), with power density of 280 watt/mm2 and exposure time 330 usec. Different
dyes (Blue, methylene, eosin, and orange) were applied to the area before irradiation to study the effect
of the pigments on the laser interaction with biological tissues. The zone of treatment (Z-necrosis) with
aid of MATLAB was determined. The relationship of zone of treatment with exposure time,
accumulated damage and fracti

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Baghdad Science Journal
Synthesis AgO Nanoparticles by Nd:Yag Laser with Different Pulse Energies
...Show More Authors

     One technique used to prepare nanoparticles material is Pulsed Laser Ablation in Liquid (PLAL), Silver Oxide nanoparticles (AgO) were prepared by using  this technique, where silver target was submerged in ultra-pure water (UPW)  at room temperature after that Nd:Yag laser which characteristics by 1064 nm wavelength, Q-switched, and 6ns pulse duration was used to irradiated silver target. This preparation method was used to study the effects of laser irradiation on Nanoparticles synthesized by used varying laser pulse energy 1000 mJ, 500 mJ, and 100 mJ, with 500 pulses each time on the particle size. Nanoparticles are characterized using XRD, SEM, AFM, and UV-Visible spectroscopy. All the structural peaks determined by the XRD

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Jan 23 2020
Journal Name
Iraqi Journal Of Laser
Spider Veins Treatment using 1064 nm Long-Pulse Nd:YAG Laser
...Show More Authors

spider veins are clusters of Ectatic venules & are common finding on the lower limbs generally believed to be caused by multiple factors, including genetic predisposition, hormonal factors, gravity, occupation, pregnancy, becoming increasingly apparent with age, and trauma. Therapeutic options include sclerotherapy, surgical procedures, and treatment with different laser systems.

 Objectives: The purpose of the study was to evaluate the efficacy and safety of long pulsed (Nd:YAG) laser emitting at 1064nm in the treatment of spider veins.

Patients, Materials and Methods: This prospective study was done in the laser medicine research clinics of the Institute of las

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2022
Journal Name
Baghdad Science Journal
Synthesis, Characterization, and Investigation the Inhibitory Impact of Thiosemicarbazide Derivative toward the Corrosion of Mild Steel in Acidic Media
...Show More Authors

        In this study we focused on the determination of influence the novel synthesized thiosemicarbazide derivative "2-(2-hydroxy-3-methoxybenzylidene) hydrazinecarbothioamide" (HMHC) influenced the corrosion inhibition of mild steel (MS) in a 1.0 M hydrochloric acid acidic solution.This is in an effort to preserve the metal material by maintaining it from corrosion.The synthesized inhibitor was characterized using elemental analysis, and NMR-spectroscopy. Then the corrosion inhibition capability of (HMHC) was studied on mild steel in an acidic medium by weight loss technique within variables [temperature, inhibitor concentration, and time]. The immersion periods were [1:00, 3:00, 5:00, 10:00, 24:00, and 72:00] hours and the tem

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sun Dec 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effect of Time and Corrosion Products Formation on Corrosion Rate of Carbon Steel Pipe Under Turbulent Flow Conditions
...Show More Authors

The effect of time (or corrosion products formation) on corrosion rates of carbon steel pipe in aerated 0.1N NaCl
solution under turbulent flow conditions is investigated. Tests are conducted using electrochemical polarization
technique by determining the limiting current density of oxygen reduction in Reynolds number range of 15000 to 110000
and temperature range of 30 to 60oC. The effect of corrosion products formation on the friction factor is studied and
discussed. Corrosion process is analyzed as a mass transfer operation and the mass transfer theory is employed to
express the corrosion rate. The results are compared with many proposed models particularly those based on the
concept of analogy among momentum, heat,

... Show More
View Publication Preview PDF