Aim: surface modification of titanium using fiber laser 1064 nm to enhance the bond strength to resin cement. Material and Methods: thirty titanium discs of 0.6 cm x 0.3 cm (diameter and thickness respectively) were categorized after preparation into three groups (n=10) as follows: control group with no surface treatment and two test groups were treated with fiber laser after estimation the appropriate parameters in the pilot study which are 81 ns pulse duration, 30,000 Hz frequency, 50 µm spot size and 10,000 mm/s scanning speed and different average power values (10 W and 20 W) depending on the tested group. Titanium discs surface characterization was performed by scanning electron microscope (SEM), and surface roughness tester. Following these tests, resin cement application to titanium discs was performed. Shear bond strength (SBS) values were determined by universal testing machine. ANOVA and Tukey HSD tests were used for analyzing of data (α = 0.05).Results: Higher average surface roughness (Ra) value was observed in (10 W) group followed by (20 W) group and the lowest surface roughness value was in the control group, additionally lowest SBS value was obtained from the control group and the highest SBS value was obtained from (20 W) group followed by (10 W) group. Conclusion: bond strength between titanium and resin cement can be significantly enhanced by using fiber laser as a surface treatment. Average power of fiber laser is essential parameter in enhancing the roughness of titanium surface and bonding to resin cement.
The mutagenic effect of some crucifers widely consumed Lepiduim sativum (Garden cress) and Arugula (Eruca sativa) was studied in comparison to carrot (Daucus carota), using bacterial mutagenic system composed of three bacterial isolates; (Bacillus spp)G3 (Arthrobacter spp)G12, and (Brevibacterium spp)G27 ,. Treatment of isolates with plant extracts led to reduction in survival fraction (Sx)at different levels except that Aurgula extract did not show any inhibitory effect in isolates G12 and G27. Crucifers extracts induced streptomycin resistant mutants in G12 at higher level than G3 , but not in G27. No resistance to rifimpacin was detected in all isolates.
Due to the increasing interest in the quality of auditing by writers, researchers and regulators of the auditing profession. The matter necessitated a statement of the extent to which the auditor practices professional skepticism, because of its significant impact in discovering errors and material misrepresentations contained in the financial statements in order to give the financial community confidence in them and the success of the audit process. The research aims to clarify the concept and importance of the practice of professional skepticism and its effect on the quality of the auditor's performance in Iraq. To achieve the research objectives, the two re
... Show MoreThis study was conducted to estimate some heavy metals cadmium, lead, nickel and iron in 15 samples of Iraqi honey with 3 replicates for each sample which were collected from apiaries near potential contamination areas in five Iraqi governorates, including Baghdad, Karbala, Babylon, Diyala and Salah al-Din. The atomic absorption technique was used to estimate the concentrations of heavy metals, the results showed that there were significant differences at (P≤0.05) between the concentrations of these elements in the honey samples, the highest concentrations of cadmium 0.123 mg/kg were recorded in Baghdad, near the petrochemical production complex, lead 4.657 mg/kg and nickel 0.023 mg/kg in Babylon near the power plant, iron was
... Show MoreBackground: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M
... Show MoreBackground: The study aim was to evaluate thermocycling effect on microleakage of occlusal and cervical margins of MOD cavity filled with bulk filled composites in comparison to incrementally placed nanohybrid composite and to evaluate the difference in microleakage between enamel and dentin margins for the three materials groups. Materials and method: Forty eight maxillary first premolars were prepared with MOD cavities. Samples were divided into three groups of sixteen teeth according to material used: Grandio: Grandio. SDR: SDR +Grandio. X-tra: X-tra base + Grandio. Each group was subdivided into two according to be thermocycled or not. After 24 hrs immersion in 2% methylene blue, samples weresectioned and microleakage was estimated. Res
... Show Moreلمعرفة مدى تأثير تمرينات مهارية وفق تقنية تركيز للتفكير الجاني على الدقة الحركة وتعلم هجمة الإيقاف بالغطس للطلاب في سلاح الشيش استخدمت الباحثتان المنهج التجريبي على عينة من طلاب المرحلة الثالثة بكلية التربية البدنية وعلوم الرياضة –جامعة ديالى والتي بلغت (30) طالباً موزعين على مجموعتين التجريبية والضابطة وبعد إكمال اجراءات البحث وتطبيق الاختبارات القبلية وتنفيذ التمرينات والاختبار البعدي ومعالجة الب
... Show MoreA Survey Study Of A Sample Of The Public Of Baghdad Governorate
The current study aimed to identify the most prominent psychological and behavioral repercussions of the exposure of the elderly to the news of the Corona pandemic and to determine the mechanisms of their exposure. On an intended sample on both sides of (Al-Karkh and Al-Rasafa) and the simple random sample was adopted to choose the place of distribution of the questionnaire and the intentional sample.
The research concluded several results, most TV news is still a primary source of information and that most of the sample move between stations to see more information about the pandemic and that the presentation of views confuses the elderly ،There
... Show MoreBackground: Atrophic postoperative and traumatic scarring are common cosmetic problems for patients. Combining CO2 laser ablation with a fractional photothermolysis system in a treatment known as ablative fractional resurfacing fulfilling the new demands for a lesser risk of side effects and minimal or no downtime.Objective: To assess the safety and efficacy of ablation fractional CO2 laser treatments for surgical scarring .methods: Twenty one patient ( 14 women, and 7 men ) with various skin types , I to IV , aged 3 to 48 years , presents with 24 scars between June and December 2012 , four patients excluded from study because they are not continued in follow up , the remaining 17 patient completed all 3 treatments & 6 months follow
... Show MoreThere are many causes for epistaxis but it is mainly idiopathic in type. In Management of epistaxis there are different modality either medical or cautery(chemical or galvanic) recently laser is used in management of epistaxis. The type of laser used in current study was 810 nm diode laser. The aim of the study is to evaluate its efficiency in control of active and non active idiopathic epistaxis; The design of the study is interventional therapeutic trial. The study was performed from December 2011 to December 2012 in Al Yarmouk teaching hospital at otorhinolaryngology department. In current study the diode laser is used in different power with same exposure time in all application; The power density is measured and choose the best one
... Show MoreLaser drilling is capable of producing small, precisely positioned holes with high degree of reproductively. In this paper , IR millisecond Nd:YAG single pulsed laser was used to determine the effect of laser parameters on the drilled hole of the glass - fiber reinforced epoxy composite FR-4 sample of 2 mm in thickness . The type of laser source was GSI lumonics JK760TR Series laser 1.064μm system in a CNC cabin. The JK760TR series has a 0.3-50ms pulse length and a maximum repetition rate 500Hz with an average power of 600W. The investigation of single pulse laser drilling in this paper was based on theoretical and experimental solutions. In single pulse technique, the investigation included focal plane position fpp, pulse shap
... Show More