Preferred Language
Articles
/
ijl-302
PDF Treatment of intraoral pyogenic granuloma with diode laser 810-980 nmarch
...Show More Authors

Background: Pyogenic granuloma is a hyperplastic benign tumor. The most common intra-oral site is marginal gingiva. It is often occurred in the second decade of life, it has a strong tendency to recur after simple excision.

The aim of study: to evaluate the therapeutic advantages of diode laser (810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:100.000). To achieve hemostasis and minimize bleeding, the lesions were completely eliminated by sweeping the laser fiber tip across the operated site. To allow the wounds to heal, they were not sutured. Then, the specimens sent for histopathology.

Results & Conclusions: In the present study, we noticed that the scale of pain, bleeding and oedema gradually decreased during the first two visits. the measured parameters were completely disappeared after two weeks in most cases as well as the patient satisfaction and function also improved. the Patients were recalled after two weeks, the wounds had completely healed and patients were not complaining any type of discomfort. it is generally believed that poor oral hygiene and poor fitting denture may lead to recurrence. According to obtained results; removal of pyogenic granuloma with diode laser (810-980 nm) is successful, effective and reasonable alternative to conventional scalpel technique.

The aim of study: to evaluate the therapeutic advantages of QuickLase dentalase diode laser(810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:100.000). To achieve hemostasis and minimize bleeding, the lesions were completely eliminated by sweeping the laser fiber tip across the operated site. To allow the wounds to heal, they were not sutured. Then, the specimens sent for histopathology.

Results & Conclusions: In the present study, We noticed that the scale of pain,bleeding and oedema gradually decreased during the first two visits. the measured parameters were completely disappeared after two weeks in most cases as well as the patient satisfaction and function also improved. the Patients were recalled after two weeks, the wounds had completely healed and patients were not complaining any type of discomfort. it is generally  believed that poor oral hygiene and poor fitting denture may lead to recurrence. According to obtained results; removal of pyogenic granuloma with QuickLase dentalase diode laser (810-980 nm) is successful ,effective and reasonable alternative to conventional scalpel technique.

Keywords: pyogenic granuloma, QuickLase, benign hyperplasia, laser institution, Baghdad.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 07 2009
Journal Name
Baghdad Science Journal
Changes of the susceptibility of Staphylococcus aureus bacteria to the local therapeutic agent by using Nitrogen laser
...Show More Authors

This study involves the investigation of the effect of nitrogen laser with 337.1 nm wavelength on the sensitivity of Staphylococcus aureus bacteria by using local therapeutic due to burns. Thirty six isolate of Staphylococcus aureus bacteria were isolated from 25 patients suffering from sever burns, each isolate of bacteria was irradiated with nitrogen laser at (5, 10, 15 and 30) pulses/second repetition rates for 1, 5, 10, 20 and 30 minutes for each repetition rate. The effects of nitrogen laser on the local therapeutics sensitivity of bacteria were obtained using Kirby Baur method. Changes in the sensitivity of bacteria to local therapeutics (Tetracyclin, Chloramphenicol, Flumizin and Fucidin) occur at high repetition rate(30 pulses/seco

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Engineering
Effect of laser process an inclined surface cutting of mild steel then analysis data statistically by RSM
...Show More Authors

The regression analysis process is used to study and predicate the surface response by using the design of experiment (DOE) as well as roughness calculation through developing a mathematical model. In this study; response surface methodology and the particular solution technique are used. Design of experiment used a series of the structured statistical analytic approach to investigate the relationship between some parameters and their responses. Surface roughness is one of the important parameters which play an important role. Also, its found that the cutting speed can result in small effects on surface roughness. This work is focusing on all considerations to make interaction between the parameters (position of influenc

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Plasma Medicine
Thermal Effect of Laser on Silver Nanoparticles Synthesized by the Cold Plasma Method on Cancer Cells
...Show More Authors

In this study, silver nanoparticles (AgNPs) were synthesized using a cold plasma technique and a plasma jet. They were then used to explore how photothermal treatment may be used to treat lung cancer (A549) and normal cells (REF) <i>in vitro</i>. The anti-proliferative activity of these nanoparticles was studied after A549 cells were treated with (AgNPs) at various concentrations (100&#37;, 50&#37;, or 25&#37;) and exposure times (6 or 8 min) of laser after 1 h or 24 h from exposed AgNPs. The highest growth inhibition for cancer cells is (75&#37;) at (AgNPs) concentration (100&#37;) and the period of exposure to the laser is (8 min). Particle size for the prepared samples varied according to the diameter o

... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Iraqi Journal Of Physics
Optimum diameter for laser beam and effect of temperature rise on the optical bistability hysteresis loops
...Show More Authors

 In this research, analytical study for simulating a Fabry-Perot bistable etalon (F-P cavity) filled with a dispersive optimized nonlinear optical material (Kerr type) such as semiconductors Indium Antimonide (InSb). An optimization procedure using reflective (~85%) InSb etalon (~50µm) thick is described. For this etalon with a (50 µm) spot diameter beam, the minimum switching power is (~0.078 mW) and switching time is (~150 ns), leading to a switching energy of (~11.77 pJ) for this device. Also, the main role played by the temperature to change the etalon characteristic from nonlinear to linear dynamics.

View Publication Preview PDF
Crossref
Publication Date
Sat Mar 01 2008
Journal Name
Iraqi Journal Of Physics
Effect of Nd-YAG, XeCl, and Nitrogen Laser Radiation on Human Aorta , and Some Arterial Tissues
...Show More Authors

The effect of laser radiation on human aorta, coronary, and pulmonary arteries, and pulmonary veins has been investigated. Xenon-Chloride (eximer), Nitrogen, and Nd-YAG pulsed lasers of wavelengths 308, 337, and 1060 nm respectively were used. Their effects on fresh postmortem tissues, normal and diseased, was studied. The diameter and depth of ablation of the exposed tissues, in air, were measured as a function of many factors related to the type of laser and nature of the tissue. The effect of properties of the applied lasers, such as average power density and deposited energy density, on the exposed tissue surface were studied. The increase of these two parameters cause an increase in the depth and diameter of ablation. However the di

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Design Considerations of Laser Source in a Ring Network Based on Fiber Distributed Data Interface (FDDI)
...Show More Authors

This work presents the use of laser diode in the fiber distributed data interface FDDI networks. FDDI uses optical fiber as a transmission media. This solves the problems resulted from the EMI, and noise. In addition it increases the security of transmission. A network with a ring topology consists of three computers was designed and implemented. The timed token protocol was used to achieve and control the process of communication over the ring. Nonreturn to zero inversion (NRZI) modulation was carried out as a part of the physical (PHY) sublayer. The optical system consists of a laser diode with wavelength of 820 nm and 2.5 mW maximum output power as a source, optical fiber as a channel, and positive intrinsic negative (PIN) photodiode

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 18 2019
Journal Name
Journal Of Laser Applications
Testing and characterization of sintered β-tricalcium phosphate coat upon zirconia dental implant using Nd:YAG laser
...Show More Authors

This study aims to fabricate and assess the β-tricalcium phosphate (β-TCP) bioactive ceramic coat layer on bioinert ceramic zirconia implants through the direct laser melting technique by applying a long-pulsed Nd:YAG laser of 1064 nm. Surface morphologies, adherence, and structural change in the coatings were evaluated by optical microscopy, field emission scanning electron microscope, hardness, and x-ray diffractometer. The elastic modulus (EM) of the coating was also determined using the nanoindentation test. The quality of the coating was improved when the laser power was 90 W with a decrease in the scan speed to 4 mm s−1. The chemical composition of the coat was maintained after laser processing; also, the Energy Dispersive

... Show More
View Publication
Scopus (10)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Physics
Structural and optical properties of ZnO doped Mg thin films deposited by pulse laser deposition (PLD)
...Show More Authors

This paper reports the effect of Mg doping on structural and optical properties of ZnO prepared by pulse laser deposition (PLD). The films deposited on glass substrate using Nd:YAG laser (1064 nm) as the light source. The structure and optical properties were characterized by X-ray diffraction (XRD) and transmittance measurements. The films grown have a polycrystalline wurtzite structure and high transmission in the UV-Vis (300-900) nm. The optical energy gap of ZnO:Mg thin films could be controlled between (3.2eV and 3.9eV). The refractive index of ZnO:Mg thin films decreases with Mg doping. The extinction coefficient and the complex dielectric constant were also investigate.

View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Jan 01 2014
Journal Name
Journal Of Thi – Qar Science
Enhanced of the Two photon Absorption in Nanostructure Wide Band gap Semiconductor CdS using femtosecond Laser
...Show More Authors

We observed strong nonlinear absorption in the CdS nanoparticles of dimension in the range 50-100 nm when irradiant with femtosecond pulsed laser at 800 nm and 120 GW/cm 2 irradiance intensity. The repetition rate and average power were 250 kHz and

View Publication
Publication Date
Mon Mar 13 2023
Journal Name
Diagnostics
The Effect of a Bioactive Oral System and CO2 Laser on Enamel Susceptibility to Acid Challenge
...Show More Authors

This study evaluated the structural changes of enamel treated by the Regenerate system and carbon dioxide (CO2) laser against acid challenge. Thirty human enamel slabs were prepared and assigned into three groups: Group I: untreated (control); Group II: treated with the Regenerate system; and Group III exposed to CO2 laser. All specimens were subjected to an acid challenge (pH 4.5–7.0) for 14 days. Specimens were evaluated and compared at 120 points using five Raman microspectroscopic peaks; the phosphate vibrations ν1, ν2, ν3, and ν4 at 960, 433, 1029, and 579 cm−1, respectively, and the carbonate at 1070 cm−1, followed by Vickers microhardness test. The ratio of carbonate to phosphate was correlated to the equivalent mic

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (7)
Scopus Clarivate Crossref