PDF Treatment of intraoral pyogenic granuloma with diode laser 810-980 nmarch
...Show More Authors

Background: Pyogenic granuloma is a hyperplastic benign tumor. The most common intra-oral site is marginal gingiva. It is often occurred in the second decade of life, it has a strong tendency to recur after simple excision.

The aim of study: to evaluate the therapeutic advantages of diode laser (810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:100.000). To achieve hemostasis and minimize bleeding, the lesions were completely eliminated by sweeping the laser fiber tip across the operated site. To allow the wounds to heal, they were not sutured. Then, the specimens sent for histopathology.

Results & Conclusions: In the present study, we noticed that the scale of pain, bleeding and oedema gradually decreased during the first two visits. the measured parameters were completely disappeared after two weeks in most cases as well as the patient satisfaction and function also improved. the Patients were recalled after two weeks, the wounds had completely healed and patients were not complaining any type of discomfort. it is generally believed that poor oral hygiene and poor fitting denture may lead to recurrence. According to obtained results; removal of pyogenic granuloma with diode laser (810-980 nm) is successful, effective and reasonable alternative to conventional scalpel technique.

The aim of study: to evaluate the therapeutic advantages of QuickLase dentalase diode laser(810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:100.000). To achieve hemostasis and minimize bleeding, the lesions were completely eliminated by sweeping the laser fiber tip across the operated site. To allow the wounds to heal, they were not sutured. Then, the specimens sent for histopathology.

Results & Conclusions: In the present study, We noticed that the scale of pain,bleeding and oedema gradually decreased during the first two visits. the measured parameters were completely disappeared after two weeks in most cases as well as the patient satisfaction and function also improved. the Patients were recalled after two weeks, the wounds had completely healed and patients were not complaining any type of discomfort. it is generally  believed that poor oral hygiene and poor fitting denture may lead to recurrence. According to obtained results; removal of pyogenic granuloma with QuickLase dentalase diode laser (810-980 nm) is successful ,effective and reasonable alternative to conventional scalpel technique.

Keywords: pyogenic granuloma, QuickLase, benign hyperplasia, laser institution, Baghdad.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Investigation of Thermal Stress Distribution in Laser Spot Welding Process
...Show More Authors

The objective of this paper was to study the laser spot welding process of low carbon steel sheet. The investigations were based on analytical and finite element analyses. The analytical analysis was focused on a consistent set of equations representing interaction of the laser beam with materials. The numerical analysis based on 3-D finite element analysis of heat flow during laser spot welding taken into account the temperature dependence of the physical properties and latent heat of transformations using ANSYS code V.10.0 to simulate the laser welding process. The effect of laser operating parameters on the results of the temperature profile were studied in addition to the effect on thermal stresses  and dimensions of the laser w

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 20 2012
Journal Name
J. Of University Of Anbar For Pure Science
Laser Processing For Nanoscale Size Quantum Wires of AlGaAs/GaAs
...Show More Authors

In this work we investigate and calculate theoretically the variation in a number of optoelectronic properties of AlGaAs/GaAs quantum wire laser, with emphasis on the effect of wire radius on the confinement factor, density of states and gain factor have been calculated. It is found that there exist a critical wire radius (rc) under which the confinement of carriers are very weak. Whereas, above rc the confinement factor and hence the gain increase with increasing the wire radius.

Publication Date
Fri Aug 14 2015
Journal Name
Journal Of Optoelectronics And Photonics (jop)
Preparation and Characterization of AL2O3 Nanostructures by Pulsed – Laser Deposition
...Show More Authors

Publication Date
Thu Apr 18 2024
Journal Name
Geomatics And Environmental Engineering
Error Analysis of Stonex X300 Laser Scanner Close-range Measurements
...Show More Authors

This research reports an error analysis of close-range measurements from a Stonex X300 laser scanner in order to address range uncertainty behavior based on indoor experiments under fixed environmental conditions. The analysis includes procedures for estimating the precision and accuracy of the observational errors estimated from the Stonex X300 observations and conducted at intervals of 5 m within a range of 5 to 30 m. The laser 3D point cloud data of the individual scans is analyzed following a roughness analysis prior to the implementation of a Levenberg–Marquardt iterative closest points (LM-ICP) registration. This leads to identifying the level of roughness that was encountered due to the range-finder’s limitations in close

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Electronic diagnostics system for the analysis of laser beam profile
...Show More Authors

In this work the analysis of laser beam profile system ,using a two dimensional CCD (Charge Coupled Device) arrays, is established. The system is capable of producing video graphics that give a two dimensional image of laser beam. The video graphics system creates color distribution that represent the intensity distribution of the laser beam or the energy profile of the beam. The software used is capable of analyzing and displaying the profile in four different methods that is , color code intensity contouring , intensity shareholding, intensity cross section along two dimension x-y, and three dimensional plot of the beam intensity given in the same display.

View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Threshold Current Density of Al0.1Ga0.9N/GaN Triple Quantum Well Laser
...Show More Authors

Semiconductor laser is used in processing many issues related to the scientific, military, medical, industrial and agricultural fields due to its unique properties such as coherence and high strength where GaN-based components are the most efficient in this field. Current technological developments mention to the strong connection of GaN with sustainable electronic and optoelectronic devices which have high-efficiency. The threshold current density of Al0.1Ga0.9N/GaN triple quantum well laser structure was investigated to determine best values of the parameters affecting the threshold current density that are well width, average thickness of active region, cavity length, reflectivity of cavity mirrors and optical confinement factor. The opt

... Show More
View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Estimation of electron temperature for SiO2 plasma induced by laser
...Show More Authors

In this work; Silicon dioxide (SiO2) were fabricated by pulsed
laser ablation (PLA). The electron temperature was calculated by
reading the data of I-V curve of Langmuir probe which was
employed as a diagnostic technique for measuring plasma properties.
Pulsed Nd:YA Glaser was used for measuring the electron
temperature of SiO2 plasma plume under vacuum environment with
varying both pressure and axial distance from the target surface. The
electron temperature has been measured experimentally and the
effects of each of pressure and Langmuir probe distance from the
target were studied. An inverse relationship between electron
temperature and both pressure and axial distance was observed.

View Publication Preview PDF
Crossref
Publication Date
Thu May 01 2014
Journal Name
Engineering And Technology Journal
Relativistic Self-Focusing of Intense Laser Beam in Magnetized Plasma
...Show More Authors

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Cutting of Fiber-Reinforced Plastics by a CW CO2 Laser
...Show More Authors

In this work, a CW CO2 laser was used for cutting samples of the fiber-reinforced
plastics (FRP) of three different types of reinforcing material; aramide, glass and carbon.
Cutting process was investigated throughout the variation of some parameters of cutting
process and their effects on cutting quality as well as the effect of an inert gas exist in the
interaction region and finally using a mechanical chopper in order to enhance the cutting
quality. Results obtained explained the possibility to perform laser cutting with high
quality in these materials by good control of the parameters and conditions of the process.

View Publication Preview PDF
Publication Date
Wed Jun 11 2003
Journal Name
Iraqi Journal Of Laser
Q- Switched Nd:YAG Laser Annealing of Phosphorus Diffused Silicon Photodiodes
...Show More Authors

Improvement of optoelectrical characteristics of phosphorus diffused silicon photodiodes by Q-switched Nd:YAG laser pulses was investigated. Laser pulses have dissolved the precipitation of phosphorus resulted during thermal diffusion process. The experimental data show that responsivity higher than (0.32 A/W) at 850 nm can be achieved after laser annealing with (1.5 MW/cm2) for 6 shots.

View Publication Preview PDF