Preferred Language
Articles
/
ijl-302
PDF Treatment of intraoral pyogenic granuloma with diode laser 810-980 nmarch
...Show More Authors

Background: Pyogenic granuloma is a hyperplastic benign tumor. The most common intra-oral site is marginal gingiva. It is often occurred in the second decade of life, it has a strong tendency to recur after simple excision.

The aim of study: to evaluate the therapeutic advantages of diode laser (810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:100.000). To achieve hemostasis and minimize bleeding, the lesions were completely eliminated by sweeping the laser fiber tip across the operated site. To allow the wounds to heal, they were not sutured. Then, the specimens sent for histopathology.

Results & Conclusions: In the present study, we noticed that the scale of pain, bleeding and oedema gradually decreased during the first two visits. the measured parameters were completely disappeared after two weeks in most cases as well as the patient satisfaction and function also improved. the Patients were recalled after two weeks, the wounds had completely healed and patients were not complaining any type of discomfort. it is generally believed that poor oral hygiene and poor fitting denture may lead to recurrence. According to obtained results; removal of pyogenic granuloma with diode laser (810-980 nm) is successful, effective and reasonable alternative to conventional scalpel technique.

The aim of study: to evaluate the therapeutic advantages of QuickLase dentalase diode laser(810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:100.000). To achieve hemostasis and minimize bleeding, the lesions were completely eliminated by sweeping the laser fiber tip across the operated site. To allow the wounds to heal, they were not sutured. Then, the specimens sent for histopathology.

Results & Conclusions: In the present study, We noticed that the scale of pain,bleeding and oedema gradually decreased during the first two visits. the measured parameters were completely disappeared after two weeks in most cases as well as the patient satisfaction and function also improved. the Patients were recalled after two weeks, the wounds had completely healed and patients were not complaining any type of discomfort. it is generally  believed that poor oral hygiene and poor fitting denture may lead to recurrence. According to obtained results; removal of pyogenic granuloma with QuickLase dentalase diode laser (810-980 nm) is successful ,effective and reasonable alternative to conventional scalpel technique.

Keywords: pyogenic granuloma, QuickLase, benign hyperplasia, laser institution, Baghdad.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 30 2013
Journal Name
Al-khwarizmi Engineering Journal
Effect the Grain Size on the Polymer Matrix Composites Reinforced by Reenia Particles
...Show More Authors

 Synthetic polymers such as polyurethane are used widely in the field of biomedical applications such as implants or part of implant systems.

This paper focuses on the preparation of base polymer matrix composite materials by (Hand Lay-Up) method, and studying the effect of selected grain size (32, 53, 63, 75, and 90) µm of (Reenia) particles on some properties of the prepared composite.

Mechanical tests were used to evaluate the prepared system (Tensile, Compression, Impact, and Hardness) tests, and a physical test of (Water absorption %), and all tests were accomplished at room temperature.

Where results showed tensile test (maximum tensile strength and modulus of elasticity) high at small grain size while

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2022
Journal Name
Environmental Research
Can electrocoagulation technology be integrated with wastewater treatment systems to improve treatment efficiency?
...Show More Authors

View Publication
Scopus (63)
Crossref (58)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Environmental Research
Can electrocoagulation technology be integrated with wastewater treatment systems to improve treatment efficiency?
...Show More Authors

Considerable amounts of domestic and industrial wastewater that should be treated before reuse are discharged into the environment annually. Electrocoagulation is an electrochemical technology in which electrical current is conducted through electrodes, it is mainly used to remove several types of wastewater pollutants, such as dyes, toxic materials, oil content, chemical oxygen demand, and salinity, individually or in combination with other processes. Electrocoagulation technology used in hybrid systems along with other technologies for wastewater treatment are reviewed in this work, and the articles reviewed herein were published from 2018 to 2021. Electrocoagulation is widely employed in integrated systems with other electrochemical tech

... Show More
View Publication
Scopus (63)
Crossref (58)
Scopus Clarivate Crossref
Publication Date
Wed Oct 07 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Association Between Carbamazepine Toxicity, Liver Bile Duct Injury, Granuloma and Inflammatory Cells Infiltration in Female Mice
...Show More Authors

The liver is an important organ in the body that can be affected by many drugs and toxins. The hepatotoxins can cause oxidant stress that lead to activation of inflammatory cells and cause liver damage. Drug induced bile duct injuries are related to drug toxicity, multiple drugs have been known to cause the development of liver granulomas. Carbamazepine (CBZ) among other antiepileptic drugs is believed to cause hepatic injury. In this study we investigated the effect of (CBZ) 20mg/kg/day on female mice liver after 14 and 30 days of treatment. The histological findings showed that (CBZ) can cause histological alterations in the liver components such as bile duct proliferation, biliary hypertrophy, ductopenia, inflammatory cells infiltration

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Baghdad Science Journal
Synthesis and Structural Determination of 6-O-prop-2-ynyl-1,2:3,4-di-O-Isopropylidene-α-D-Galactose
...Show More Authors

In this work, an important sugar alkynyl ether has been synthesized in two subsequent steps starting from commercially available D-galactose (3). This kind of compounds is highly significant in the synthesis of biologically active molecules such as 1,2,3-triazole and isoxazoles. In the first step, galactose (3) was reacted with acetone in the presence of anhydrous copper (II) sulfate to produce 1,2:3,4-di-O-isopropylidene-α-D-galactose (4) in good yield. The latter was reacted with excess of 3-bromoprop-1-yne in DMF in the presence of NaOH pellets to afford the target molecule 5 in a very good yield. The temperature of this step is crucial in determining the reaction yi

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Al-khwarizmi Engineering Journal
Improvement of Dynamic Buckling Behavior of Intermediate Aluminized Stainless Steel Columns
...Show More Authors

This paper experimentally investigated the dynamic buckling behavior of AISI 303 stainless steel aluminized and as received intermediate columns.  Twenty seven specimens without aluminizing (type 1) and 75 specimens with hot-dip aluminizing at different aluminizing conditions of dipping temperature and dipping time (type 2), were tested under dynamic compression loading (compression and torsion), dynamic bending loading (bending and torsion), and under dynamic combined loading (compression, bending, and torsion) by using a rotating buckling test machine. The experimental results werecompared with tangent modulus theory, reduced modulus theory, and Perry Robertson interaction formula. Reduced modulus was formulated to circular cross-

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Apr 10 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of ER: YAG laser on enamel resistance to caries during orthodontic treatment: An in vitro study
...Show More Authors

Background: One common undesirable side effect of orthodontic treatment with fixed appliances is the development of incipient caries lesions around brackets, particularly in patients with poor oral hygiene. Different methods have been used to prevent demineralization; the recent effort to improve the resistance against the demineralization is by the application of lasers. Materials and method: Thirty human premolars extracted for orthodontic purposes were used to test the effect of two energy level of ER-YAG laser on enamel resistance to demineralization. The brackets were bonded on the teeth and all the labial surface excluding 2 mm area gingival to the brackets were painted with acid resistance varnish. Three groups were generated. The fi

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 20 2022
Journal Name
Journal Of Clinical Medicine
Comparison of the Safety and Efficacy of Laser Versus Pneumatic Intracorporeal Lithotripsy for Treatment of Bladder Stones in Children
...Show More Authors

This study aimed to compare the safety and efficacy of laser lithotripsy and pneumatic lithotripsy, the two most commonly used transurethral lithotripsy methods for treating bladder stones in children in Iraq. Between January 2013 and December 2016, 64 children with bladder stones were included in this prospective randomized study, after ethical committee approval and written consent from the children’s parents or caregivers were obtained. Patients were assigned randomly by computer software to two groups treated with either pneumatic cystolithotripsy or laser lithotripsy. A 9 Fr. semirigid ureteroscope was used to pass the lithotripter through and fragment the stone. A catheter of 8–12 Fr. was then introduced and kept in place

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
Voice Identification Using MFCC and Vector Quantization
...Show More Authors

The speaker identification is one of the fundamental problems in speech processing and voice modeling. The speaker identification applications include authentication in critical security systems and the accuracy of the selection. Large-scale voice recognition applications are a major challenge. Quick search in the speaker database requires fast, modern techniques and relies on artificial intelligence to achieve the desired results from the system. Many efforts are made to achieve this through the establishment of variable-based systems and the development of new methodologies for speaker identification. Speaker identification is the process of recognizing who is speaking using the characteristics extracted from the speech's waves like pi

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Fri Nov 20 2015
Journal Name
Iraqi Journal Of Science
New Approach for Determination of Oxonium Ion in Inorganic Acids by Quenched Fluorescence of Analytically Interested Species via the Liberated Bromine Using Continuous Flow Injection Laser Diode Fluorimeter Analyser
...Show More Authors

A new method is characterized by simplicity, accuracy and speed for determination of Oxonuim ion in ionisable inorganic acid such as hydrochloric (0.1 - 10) ,Sulphuric ( 0.1 - 6 ),nitric ( 0.1 - 10 ), perchloric ( 0.1 - 7 ), acetic (0.1 - 100 ) and phosphoric ( 0.1 - 30 ) ( mMol.L-1 )acids. By continuous flow injection analysis. The proposed method was based on generation of bromine from the Bro-3-Br-- H3O+. Bromine reacts with fluorescein to quenches the fluorescence . A sample volume no.1 (31μl) and no.2 (35μl) were used with flow rate of 0.95 mL.min-1 using H2O line no.1as carrier stream and 1.3 mL.min-1 using fluorescein sodium salt line no.2. Linear regression of the concentration ( mMol.L-1 ) Vs quenched fluorescence gives a correla

... Show More
View Publication