Photonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and the characterization of a relative humidity sensor based on a polymer-coated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) transmission mode. The fabrication of the sensor involved splicing a short (1 cm) length of Photonic Crystal Fiber (PCF) between two single-mode fibers (SMF). It was then coated with a layer of agarose solution. Experimental results showed that a high humidity sensitivity of 29.37 pm/%RH was achieved within a measurement range of 27–95%RH. The sensor also showed good repeatability, small size, measurement accuracy and wide humidity range. The RH sensitivity of the sensor has a significant dependence on the thickness of the coating and the sensor with the highest sensitivity showed a linear response for RH change in the range of 27-95% RH and a fast response time of 0.8 sec for an RH change from 50% to 90%.
This study was undertaken to diagnose routine settling problems within a third-party oil and gas companies’ Mono-Ethylene Glycol (MEG) regeneration system. Two primary issues were identified including; a) low particle size (<40 μm) resulting in poor settlement within high viscosity MEG solution and b) exposure to hydrocarbon condensate causing modification of particle surface properties through oil-wetting of the particle surface. Analysis of oil-wetted quartz and iron carbonate (FeCO₃) settlement behavior found a greater tendency to remain suspended in the solution and be removed in the rich MEG effluent stream or to strongly float and accumulate at the liquid-vapor interface in comparison to naturally water-wetted particles. As su
... Show MoreThe advancements in horizontal drilling combined with hydraulic fracturing have been historically proven as the most viable technologies in the exploitation of unconventional resources (e.g., shale and tight gas reservoirs). However, the number of fractures, well timing, and arrangement pattern can have a significant impact on the project economy. Therefore, such design and operating parameters need to be efficiently optimized for obtaining the best production performance from unconventional gas reservoirs. In this study, the process of selecting the optimal number of fractures was conducted on a section of a tight gas reservoir model (based on data from the Whicher Range (WR) tight gas field in Western Australia). Then, the optimal number
... Show MoreA comparison between the resistance capacity of a single pile excited by two opposite rotary machines embedded in dry and saturated sandy soil was considered experimentally. A small-scale physical model was manufactured to accomplish the experimental work in the laboratory. The physical model consists of: two small motors supplied with eccentric mass 0·012 kg and eccentric distance 20 mm representing the two opposite rotary machines, an aluminum shaft with 20 mm in diameter as the pile, and a steel plate with dimensions of (160 × 160 × 20 mm) as a pile cap. The experimental work was achieved taking the following parameters into consideration, pile embedment depth ratio (L/d; length to diameter) and operating freq
... Show MorePesticide poisoning is a serious global public health issue and is responsible for a sizable number of annual fatalities. This study was designed to examine the potentially harmful effects of adult rats being exposed to imidacloprid (IMD) as a nanoparticle by determining the chronic effect of inhalation of (5,10 and 20) mg/kg/b.w. of nano-imidacloprid for a duration of 60 days. The most important biochemical parameters of the serum liver function parameters were aspartate aminotransferase (AST), alanine aminotransferase (ALT), and alkaline phosphatase ALP, kidney function [blood urea, creatinine, and urea], and oxidative stress parameters (MDA, GSH, and CAT) in all treated groups when
This study investigates the effectiveness of mental games in enhancing shooting accuracy among young basketball players. Initially, baseline shooting accuracy was assessed through tests conducted prior to a three-week intervention involving mental games. A follow-up test revealed a significant improvement in participants' shooting accuracy following the intervention. Given the noticeable differences in the new shooting scores compared to the initial assessments, a second set of pre-intervention tests was conducted. These tests reaffirmed the significant enhancement in shooting accuracy, substantiating the hypothesis that mental games positively affect performance. The findings highlight the importance of these intervention programs
... Show MoreThis work aim to prepare Ag/R6G/PMMA nanocomposite thin
films by In-situ plasma polymerization and study the changes in the
optical properties of fluorophore due to the presence of Ag
nanoparticles structures in the vicinity of the R6G laser dye. The
concentrations of R6G dye/MMA used are: 10-4M solutions were
prepared by dissolving the required quantity of the R6G dye in
MMAMonomer. Then Silver nanoparticles with 50 average particles
size were mixed with MMAmonomer with concentration of 0.3, 0.5,
0.7wt% to get R6G silver/MMA in liquid phase. The films were
deposited on glass substrates by dielectric barrier discharge plasma
jet. The Ag/R6G/PMMA nanocomposite thin films were
characterization by UV-Visible
Two different composite materials were prepared by stir casting method of AA 6061 alloy as a matrix reinforced with two addition different ceramic materials Al2O3 and B4C of grain size 20 µm by 2.5, 5, 7.5 and10% in weight. The composite material with aluminum alloy as a matrix possesses a unique mechanical properties such as: high specific strength and hardness, low density, and high resistance to corrosion and friction wear. This composite is widely used in automotive parts space and marine applications.
Pin-on-disc technique was used to calculate the wear rate for each addition of Al2O3 and B4C particles. Rockwell hardness test and
... Show MoreIn this work, the plasma parameters (electron temperature and
electron density) were determined by optical emission spectroscopy
(OES) produced by the RF magnetron Zn plasma produced by
oxygen and argon at different working pressure. The spectrum was
recorded by spectrometer supplied with CCD camera, computer and
NIST standard of neutral and ionic lines of Zn, argon and oxygen.
The effects of pressure on plasma parameters were studied and a
comparison between the two gasses was made.
Sixty albino female mice were used in this experiment to study the possible effect of the crude alcoholic extract of the celery leaves on their fertility. These animals were randomly and equally divided into three experimental groups (20 females/group). The first and second groups were orally given a daily dose of 500 and 1000 mg/kg body weight, respectively, of the crude alcoholic extract, while the third group (control) was similarly treated, at the same time, with 0.1 ml/gm body weight of physiological saline for comparison. The treatment, however, lasted for 25 consecutive days. On day 26, after treatment was stopped, the life body weight of all animals was recorded before sacrificing the animals. Thereafter blood
... Show More