Background: preparation of root canals is an important step in root canal treatment. Mechanical instrumentation of root canals cause an irregular layer of debris, known as the smear layer. As a result, several studies reported that preferring the removal of the smear layer. Objective: To study the influence of the energy (100 mJ) of Erbium, Chromium: Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) laser at short pulse duration (60 μs) on smear layer removal of apical third after using Photon induced photoacoustic streaming technique. Materials and methods: Eighteen straight single-rooted mandibular premolars were used. The roots length were uniform to 14mm from the anatomic apex and instrumented using Protaper Gold Rotary NiTi file system to size 40 taper 0.06. Er,Cr:YSGG pulsed laser (waterlase iplus Biolase, CA, USA) 2780 nm was used at short pulse duration (60 μs, 5 Hz ,air and water off) delivered by MD/iplus Glass Tips (MZ6) 600 μm in diameter, length=6 mm, calibration factor= 1.00. Ultrasonic activator ENDO1 (Guilin Woodpecker Medical Instrument Co., Ltd.china) was used with Ultrasonic activator tip ED98 (25#, 2% taper, 18.5mm) (Guilin Woodpecker Medical Instrument Co., Ltd.china). The samples were arbitrarily divided into three groups (n=6) and used as follows: (A) conventional irrigation with 5 ml of 17 % EDTA, (B) passive ultrasonic irrigation with 5 ml of 17 % EDTA, (C) Er,Cr:YSGG induced photoacoustic streaming with 5 ml of 17 % EDTA. After final irrigation with normal saline and drying, the roots were painted with nail varnish externally, and 2% methylene blue dye injected into canal until the canal filled with dye. The tooth was splitted at the fourth millimeters from root apex with a diamond disc representing the apical third. Picture was taken by Professional Digital SLR camera (Nikon D7100, Nikon Corporation, Thailand) with 40X magnification. The dye penetration was measured by using analytical software (measure picture CAD-KAS Kessler Germany). ANOVA test was used to analyse repeated measure mean between tested concentration (5.25% NaOCL, 17% EDTA) and control. Data was expressed as mean±SD. LSD (Least Significant Difference) test was used to calculate the significant differences between tested mean. Results: The mean values of the percentage of dye penetration area in two experimental groups was higher than the control group, as the follow (20.79±1.15control, 34.5453±0.45 ultrasonic group, 85.9804±2.69 Er,Cr.YSGG+17%EDTA at 0.5 W). The Percentage of dye penetration in Er,Cr:YSGG laser induced photoacoustic streaming with 17% EDTA was significantly high (P value 0.001), followed by ultrasonic activated group, while control group result in less Percentage of dye penetration than both study groups. Conclusion: In this study, we concluded that Er,Cr:YSGG pulsed laser (0.5 W,5 Hz , air and water off) at short pulse duration (60 μs) with 17% EDTA using PIPS technique for activation of irrigant in endodontic treatment give better result than ultrasonic activation in smear layer removal
The aim of the present work to study the effect of changing velocity (Reynold's number) on oxygen cathodic polarization using brass rotating cylinder electrode in 0.1, 0.3 and 0.5N NaCl solutions (PH = 7) at temperatures 40, 50 and 600 C. Cathodic polarization experiments were conducted as a function of electrode rotational speed and concentration.
The Sequencing Batch Reactor system (SBR) is a major component of the municipal wastewater biological treatment system and water reclamation that provides high-quality water that could be reused in restricted plants that which require large quantities of water despite the lack of water. The research aims to investigate the performance of a pilot plant SBR unit under real operation conditions that was installed and operated in Al-Rustamiya Wastewater Treatment Plant (WWTP), Baghdad, Iraq. Results showed that the BOD5/COD ratio of the raw wastewater was within the average value at 0.66 emphasizing the organic nature of the influent flow and hence the amenability to biological treatment. The results also ensured that the treatment pro
... Show MoreIn the present study, 1-ethyl -3-methyllimidazolium acetate ionic liquid is introduced for extractive desulfurization of Iraqi kerosene (1622ppm) and compared with 1-ethyl -3- methyllimidazolium tetrafloroborate. The effect of ionic liquid/ fuel ratio (1/9, 1/4, 1/2), temperature (25, 30,40oC), stirring speed (300,450rpm) and time (10, 30, 90, 180, 360 min) were studied. Sulfur compound analysis was performed using X-Ray fluorescence. The ionic liquid with acetate anion (OAc) showed better performance than tetrafloborate (BF4). The maximum extraction efficiency was 32% achieved at 1/2 IL/Fuel and 40oC after 90min. The oxidation step using hydrogen peroxide (8ml/200ml), catalyzed by acetic acid (2ml) and followed by ionic liquid extraction h
... Show MoreLiquid – liquid equilibria data were measured at 293.15 K for the pseudo ternary system (sulfolane + alkanol) + octane + toluene. It is observed that the selectivity of pure sulfolane increases with cosolvent methanol but decreases with increasing the chain length of hydrocarbon in 1-alkanol. The nonrandom two liquid (NRTL) model, UNIQUAC model and UNIFAC model were used to correlate the experimental data and to predict the phase composition of the systems studied. The calculation based on NRTL model gave a good representation of the experimental tie-line data for all systems studied. The agreement between the correlated and the experimental results was very good
Abstract
The aim of this paper is to investigate and discuss the mechanisms of corrosion of epoxy coatings used for potable water tanks. Two distinct types of Jotun epoxy coatings: Tankguard 412 contained polyamine cured epoxy and Penguard HB contained polyamide cured epoxy, were tested and studied using the electrochemical impedance spectroscopic (EIS) method. The porosity of epoxy coatings was determined using EIS method. The obtained results showed that the two epoxy coatings have excellent behavior when applied and tested in potable water of Basrah city. Polyamine is more resistance to water corrosion compared to polyamide curing epoxy and has high impedance values. Microscopic inspection after te
... Show MoreRadiotherapy is medical use of ionizing radiation, and commonly applied to the cancerous tumor because of its ability to control cell growth. The amount of radiation used in photon radiation therapy called dose (measured in grey unit), which depend on the type and stage of cancer being treated. In our work, we studied the dose distribution given to the tumor at different depths (zero-20 cm) treated with different field size (4×4- 23×23 cm). Results show that the deeper treated area has less dose rate at the same beam quality and quantity. Also it has been noted increasing in the field increasing in the depth dose at the same depth even if the radiation energy is constant. Increasing in radiation dose attributed to the scattere
... Show More