Background: Pilonidal sinus is a recurrence pathology that affects the gluteal area, cleft part of it. It affects many parts but mainly the sacral area and may present with various forms; from the asymptomatic cyst to severe infection in a form of painful abscess or sinus. The treatment of pilonidal sinus ranges from observation with good hygiene to excision of the sinus left wide incision. Recurrence may follow the excisional procedure and may need more operations. Many conservative ways had been used for the management of the sinus; laser (phototherapy) is one kind that may use. this paper aims to test the efficiency of the laser (diode 980nm) in the treatment of the sinus. material: a study of forty-seven patients complaining of the simple pilonidal sinus was managed with laser radiation of diode 980nm, ages of the patients 17- 41-year-old with a mean of 29.15 (SD ± 5.16), the length of the track between 30 mm to 70 mm. and the mean is 46.13 mm. (SD ± 10.32) all primary except 10 patients were recurrent after treatment. result: the operation was done as a day case, operation time between 6:10 to 14:10 minutes with mean 9:30 minutes. the follow-up of the patients was weekly after seen on 1st postoperative day, with no complication except one infected on 9th day after the operation, which closed on the 21st day after for 10 days with cefixime and metronidazole. the sinus closed in 6 to 30 days with a mean of 12.49. conclusion: laser radiation of diode 980nm can use with good efficacy in pilonidal disease management to avoid the excision of the sinus by conventional procedure which lead to tissues damage, and this decrease the cost, hospital stay, time to return to work, morbidity and complication, we can iterate the procedure without further damage.
The current work concerns preparing cobalt manganese ferrite (Co0.2Mn0.8Fe2O4) and decorating it with polyaniline (PAni) for supercapacitor applications. The X-ray diffraction findings (XRD) manifested a broad peak of PAni and a cubic structure of cobalt manganese ferrite with crystal sizes between 21 nm. The pictures were taken with a field emission scanning electron microscope (FE-SEM), which evidenced that the PAni has nanofibers (NFs) structures, grain size 33 – 55 nm, according to the method of preparation, where the hydrothermal method was used. The magnetic measurements (VSM) that were conducted at room temperature showed that the samples had definite magnetic properties. Additionally, it was noted that the saturation magnetizatio
... Show MoreA low-cost, RGB LED-based visible-light spectrophotometer was designed to measure dyes concentration. Dyes are widely used as indicators or coloring agents in different applications and knowing their concentration is an essential part for many studies. The proposed spectrophotometer provides many functionalities that clones the traditional expensive spectrophotometers for a budged price under $50. It was aimed to provide a versatile tool for instructors and educators to teach their students the fundamental concepts behind spectrophotometry. Malachite green, methyl red, and methyl orange dyes were chosen to be good samples to show the integrity of the proposed spectrophotometer in terms of accuracy, repeatability, and sensitivity as
... Show MoreAs result of exposure in low light-level are images with only a small number of
photons. Only the pixels in which arrive the photopulse have an intensity value
different from zero. This paper presents an easy and fast procedure for simulating
low light-level images by taking a standard well illuminated image as a reference.
The images so obtained are composed by a few illuminated pixels on a dark
background. When the number of illuminated pixels is less than 0.01% of the total
pixels number it is difficult to identify the original object.
In this work, a modern optical system based on modulation technique is constructed to achieve the retrieval of optical defects and distortions of the images behind dark barriers. A 800x600 analog spatial light modulator (SLM) is used in this technique with a 632.8nm He-Ne laser, a circular metallic mesh (CMM) is imaged and disturbed and then dealing with our system. The SLM was confirmed for irregularity improvement such as variable diffracted optical element (DOE) control. The obtained results showed that the effect of distortion has been treated and reduced to be minimum by controlling phase and amplitude modulation of the scattered wave front utilizing the SLM. The obtained images showed identical to the original image wi
... Show MoreIn this study the isomerization of desulfuerized light Iraqi petroleum naphtha (Al-Dura Refinery) with boiling point range of 37 to 124 °C , 80.5 API specific gravity and 68.2 octane number has been investigated. Two types of catalysts were prepared (Pt/HX and Pt/SrX) by impregnation of 0.8 wt% Pt on l 3X-zeolite. The catalyst activity and selectivity toward isomerization, and catalyst deactivation were investigated.
The isomerization unit consisted of a vertical tubular stainless steel reactor of 2 cm internal diameter, 3 cm external diameter and 68 cm height. The operating pressure was atmospheric for all experimental runs. The liquid flow of lightnaphtha was 0.4 Uh, and the catalyst weight was 50 gm, H/
... Show MoreMethylotrophs bacteria are ubiquitous, and they have the ability to consume single carbon (C1) which makes them biological conversion machines. It is the first study to find facultative methylotrophic bacteria in contaminated soils in Iraq. Conventional PCR was employed to amplify MxaF that encodes methanol dehydrogenase enzyme. DNA templates were extracted from bacteria isolated from five contaminated sites in Basra. The gene specific PCR detected Methylorubrum extorquens as the most dominant species in these environments. The ability of M. extorquens to degrade aliphatic hydrocarbons compound was tested at the laboratory. Within 7 days, gas chromatographic (GC) studies of remaining utilize
... Show MoreBackground This study aimed to evaluate the efficacy of once-daily liraglutide as an add-on to oral antidiabetics (OADs) on glycemic control and body weight in obese patients with inadequately controlled type 2 diabetes (T2D). Methods A total of 27 obese T2D patients who received 7 months (0.6 mg/day for the first month, 1.2 mg/day for 3 months, and 1.8 mg/day for 3 months) of liraglutide treatment as an add-on to OADs were included. Data on body weight (kg), fasting plasma glucose (FPG, mg/dL), postprandial glucose (PPG, mg/dL), and HbA1c (%), were recorded. Results Liraglutide doses of 1.2 mg/day and 1.8 mg/day were associated with significant decreases in body weight (by 8.0% and 11.9%, respectively, p < 0.01 for each) and HbA1c (by 20.0
... Show MoreIn the current endeavor, a new Schiff base of 14,15,34,35-tetrahydro-11H,31H-4,8-diaza-1,3(3,4)-ditriazola-2,6(1,4)-dibenzenacyclooctaphane-4,7-dien-15,35-dithione was synthesized. The new symmetrical Schiff base (Q) was employed as a ligand to produce new complexes comprising Co(II), Ni(II), Cu(II), Pd(II), and Pt(II) metal-ions at a ratio of 2:1 (Metal:ligand). There have been new ligands and their complexes validated by (FTIR), (UV-visible), 1H-NMR, 13C-NMR, CHNS, and FAA spectroscopy, Thermogravimetric analysis (TG), Molar conductivity, and Magnetic susceptibility. The photostabilization technique to enhance the polymer was also used. The ligand Q and its complexes were mixed in 0.5% w/w of polyvinyl chloride in tetrahydrofuran
... Show MoreBackground: This study aimed to evaluate the outcome of long-term results of dacryocystorhinostomy (DCR) techniques in specialized eye care center in Iraq.
Subjects and Method: This is a prospective study of 650 patients from July 2014 to July 2019 with nasolacrimal duct obstruction in Ibn Al Haitham Eye Teaching Hospital. A preoperative questionnaire was done, then one month, three months, six months and one year postoperatively. The success of surgery defined as follow; Absence of epiphora completely, Resolve of dacryocele or mucocele or any new attack of daryocystitis, Appearance of fluorescein dye from nose in fluorescein disappearance test, Successful irriga
... Show MoreIn this work, the effects of solvent properties on the characteristics of absorption and fluorescence for two laser dyes was studied. Dyes used in this work include Coumarin 5400 and DCM, while the solvents include ethanol, methanol, acetone, propanol and chloroform. Coumarin 5400 dye shows sharp fluorescence peaks in the green band of visible region while the DCM dye shows relatively wide band within 590-630 nm. Therefore, the selection of any dye for random gain medium applications should be performed after determining the most appropriate solvent as the optimum fluorescence characteristics are obtained.