It is found that hypersensitive teeth have a larger number and wider patent tubules than those of non-sensitive teeth. Objective: The aim of this study is to compare between the effects of diode laser at different power densities, with and without sodium fluoride on the sealing of exposed dentinal tubules and dentin permeability. Materials and methods: 118 teeth were used. Samples were divided into three major groups. The first consisted of 100 teeth used for permeability test. The second consisted of 16 teeth for measuring external surface temperature elevation while irradiation. The third, in turn, consisted of one pair of teeth observed under SEM for dentine surface morphology analysis. Results: For dentin permeability measurement, the results revealed a highly significant difference between the control group and 2, 3 W with varnish groups. For the external surface temperature elevation, the results revealed that temperature rise, for both laser alone and with varnish groups, was between (67-97.9 ∘C) at 1.6, 2 W. SEM analysis revealed that approximately optimum sealing of tubules occurred in 2W with the varnish group. Conclusions: The combined application of 940 nm diode laser at 2W with 809.7 W/cm² power densities, with sodium fluoride white varnish show a significant improvement in their effects on dentin permeability reduction as compared to each treatment alone.
The triggering effect for the face pumping of Nd:YVO4 disc medium of 4×5×0.5 mm was investigated using bulk diode laser at different resonator cavity length in pulse mode and at repetition rate of 1.3kHz. The maximum emitted peak power was found to be 100, 82, and 66 mW for resonator lengths of 10, 13.5, and 17.5 cm respectively, while the threshold pumping power was found to be 41mW. The maximum emitted peak power obtained was 300 mW when using external triggering and 10cm length, with repetition of 3Hz.
The question of estimation took a great interest in some engineering, statistical applications, various applied, human sciences, the methods provided by it helped to identify and accurately the many random processes.
In this paper, methods were used through which the reliability function, risk function, and estimation of the distribution parameters were used, and the methods are (Moment Method, Maximum Likelihood Method), where an experimental study was conducted using a simulation method for the purpose of comparing the methods to show which of these methods are competent in practical application This is based on the observations generated from the Rayleigh logarithmic distribution (RL) with sample sizes
... Show MoreThe labor inspector may be exposed - while performing his duties that are legally assigned to him - to threats or attacks on him by employers, which makes it impossible for the inspector to perform these jobs.
This has prompted international and Arab labor inspection standards, as well as national labor laws, to emphasize the need to provide security support and legal protection for the labor inspector, and to punish employers' violators, with the aim of extending the authority and prestige of the state and ensuring the enforcement of laws and thus achieving the goals for which it was legislated.
Background: White-spot lesion is one of the problems associated with the fixed orthodontic treatment. The aims of this in-vitro study were to investigate enamel damage depth on adhesive removal when the adhesive were surrounded by sound, demineralized or demineralized enamel that had been re-mineralized prior to adhesive removal using 10% Nano-Hydroxy apatite and to determine the effect of three different adhesive removal techniques. Materials and methods: Composite resin adhesive (3M Unitek) was bonded to 60 human upper premolars teeth which were randomly divided in to three groups each containing ten sound teeth and ten teeth with demineralized and re-mineralized lesions adjacent to the adhesive. A window of 2 mm was prepared on the bucca
... Show MoreThe Log-Logistic distribution is one of the important statistical distributions as it can be applied in many fields and biological experiments and other experiments, and its importance comes from the importance of determining the survival function of those experiments. The research will be summarized in making a comparison between the method of maximum likelihood and the method of least squares and the method of weighted least squares to estimate the parameters and survival function of the log-logistic distribution using the comparison criteria MSE, MAPE, IMSE, and this research was applied to real data for breast cancer patients. The results showed that the method of Maximum likelihood best in the case of estimating the paramete
... Show MoreMetric type II bursts are formed from shocks driven by CME or flares which is
indicative of particles (SEPs) accelerated to high energies. This work aims to
investigate the metric type II bursts, CMEs and flare for twenty years (1996-2016,
inclusive) over two solar cycles 23 and 24. The total metric type II bursts was 1378
events divided into two groups: first group associated with CMEs regardless their
properties and this group has (1147) events. The second group associated with flares
which has (231) events. The interstice fraction of this research is the metric type II
associated with CME is 83% whereas only 17% with flare where this very close to
the previous study in 2005 which found 81% despite it was for on
The present expermint was designed to determine the effect of Sodium Selenite (0.5 mg/kg) and Vitamin A (10 mg/kg) in FSH and LH level in Albino Male Mice treated with Hexavalent Chromium (1000 ppm). `This study included 48 mice divided into six groups (1st group treated with distilled water and the 2nd group treated with Sesame Oil were considered as control group, 3th group exposed to Hexavalent chromium , 4th group treated with Sodium Selenite and exposed to Hexavalent Chromium , 5th group treated with Vitamin A and exposed to Hexavalent Chromium and 6th group treated with Sodium Selenite and Vitamin A and exposed to Hexavalent Chromium ) . The treatment lasted for 35 days. The results showed a significant (P ? 0.05) decrease in FSH an
... Show MoreThe researcher studied transportation problem because it's great importance in the country's economy. This paper which ware studied several ways to find a solution closely to the optimization, has applied these methods to the practical reality by taking one oil derivatives which is benzene product, where the first purpose of this study is, how we can reduce the total costs of transportation for product of petrol from warehouses in the province of Baghdad, to some stations in the Karsh district and Rusafa in the same province. Secondly, how can we address the Domandes of each station by required quantity which is depending on absorptive capacity of the warehouses (quantities supply), And through r
... Show MoreWith and without the use of magnetic fields, titanium dioxide (TiO2) nanoparticles were synthesized using the hydrothermal method at extremely high temperatures and pressures. Titanium tetra isopropoxide [Ti(C12H28O4)] was used for the preparation, which was performed at pH 7 and under temperatures of 160 and 190 ˚C. UV spectroscopy, XRD crystallography, FE-SEM microscopy were used for characterizations. From UV spectroscopy, the energy gap values were clearly affected by the increase in temperature and the presence of the magnetic field. At the temperatures of 160 and 190 oC for TiO2 without magnetic field, FE-SEM microscopy images have shown an average c
... Show MoreAim: The Aim of the study is to compare between Er,Cr:YSGG 2780 nm laser and carbide fissure bur in root-end resection regarding the morphological variations, temperature changes and the duration of resection process.
Settings and Design: 5 W, 25 Hz, 50% water, 80% air,25.47 J/cm2 .
Material and method: twenty-one extracted single rooted teeth endodontically were treated, twenty teeth were obturated and divided into two groups according to method of resection. Group 1 root-end resected using cross cut carbide bur while group 2 root-end resected using laser with MGG6 sapphire tip of 600 μm diameter. Temperature on external root surface and duration of resection were recor
... Show More